文献速递流行病学与生物统计临床试验与 GCP

孕晚期通用超声筛查预测巨大儿及不良围产结局的系统评价与荟萃分析

Universal third-trimester ultrasonic screening using fetal macrosomia in the prediction of adverse perinatal outcome: A systematic review and meta-analysis of diagnostic test accuracy.
PubMed 文献 · PLoS Med · 2020-10-13

该系统评价与荟萃分析纳入41项研究共112,034例低危及混合风险孕妇,评估孕晚期通用超声胎儿生物测量预测巨大儿、肩难产及新生儿并发症的诊断准确性。结果显示EFW>4,000g或AC>36cm预测巨大儿的灵敏度>50%,阳性似然比分别为8.74和7.56;但预测肩难产的灵敏度仅22%,阳性似然比2.12。可疑LGA对巨大儿预测强,对肩难产预测弱,其他新生儿并发症数据不足。

要点

  • 孕晚期超声EFW>4,000g或AC>36cm预测巨大儿灵敏度>50%,阳性似然比高。
  • EFW>4,000g预测肩难产灵敏度仅22%,阳性似然比2.12,预测能力弱。
  • 低危及混合风险人群中,可疑LGA强烈预测巨大儿分娩风险。

核心结论

  • 在低危和混合风险人群中,超声可疑LGA强烈预测分娩巨大儿,但对肩难产的预测仅弱相关(虽有统计学显著性)。
  • 其他新生儿并发症标志物的数据不足,无法分析。

研究设计与样本

  • 系统评价与荟萃分析,检索Medline、EMBASE、Cochrane图书馆和ClinicalTrials.gov至2020年5月,无语言限制。
  • 纳入41项研究共112,034例,包括11项前瞻性队列(N=9,986)、1项RCT(N=367)和29项回顾性队列(N=101,681)。
  • 纳入超声作为通用筛查且人群为低危和混合风险妊娠的研究,排除仅限高危妊娠的研究。
  • 使用EFW(多种公式和阈值)和AC定义可疑LGA,采用QUADAS-2评估偏倚风险。
  • 采用层次summary ROC和双变量logit-normal(Reitsma)模型进行荟萃分析。

主要发现

  • EFW>4,000g(或对应孕龄第90百分位)预测巨大儿(出生体重>4,000g或第90百分位)灵敏度>50%,阳性似然比8.74(95%CI 6.84-11.17)。
  • AC>36cm(或第90百分位)预测巨大儿灵敏度>50%,阳性似然比7.56(95%CI 5.85-9.77)。
  • EFW>4,000g(或第90百分位)预测肩难产的灵敏度为22%,阳性似然比2.12(95%CI 1.34-3.35)。
  • 预测巨大儿存在显著异质性,可能反映研究设计、人群特征和所用公式的差异。
  • 仅3项研究对临床医生设盲超声结果。

关键数值与推荐

  • EFW>4,000g或第90百分位预测巨大儿:灵敏度>50%,阳性似然比8.74(95%CI 6.84-11.17)。
  • AC>36cm或第90百分位预测巨大儿:灵敏度>50%,阳性似然比7.56(95%CI 5.85-9.77)。
  • EFW>4,000g或第90百分位预测肩难产:灵敏度22%,阳性似然比2.12(95%CI 1.34-3.35)。

临床怎么用

  • 孕晚期通用超声发现EFW>4,000g或AC>36cm时,应警惕巨大儿分娩风险,但预测肩难产价值有限。
  • 临床解读超声可疑LGA结果时需结合其他临床因素,不应仅凭此预测肩难产。

局限性

  • 研究质量参差不齐,仅3项研究对超声结果设盲。
  • 预测巨大儿存在显著异质性,可能源于研究设计、人群和公式差异。
  • 其他新生儿并发症标志物数据不足,无法分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The effectiveness of screening for macrosomia is not well established. One of the critical elements of an effective screening program is the diagnostic accuracy of a test at predicting the condition. The objective of this study is to investigate the diagnostic effectiveness of universal ultrasonic fetal biometry in predicting the delivery of a macrosomic infant, shoulder dystocia, and associated neonatal morbidity in low- and mixed-risk populations. METHODS AND FINDINGS: We conducted a predefined literature search in Medline, Excerpta Medica database (EMBASE), the Cochrane library and ClinicalTrials.gov from inception to May 2020. No language restrictions were applied. We included studies where the ultrasound was performed as part of universal screening and those that included low- and mixed-risk pregnancies and excluded studies confined to high risk pregnancies. We used the estimated fetal weight (EFW) (multiple formulas and thresholds) and the abdominal circumference (AC) to define suspected large for gestational age (LGA). Adverse perinatal outcomes included macrosomia (multiple thresholds), shoulder dystocia, and other markers of neonatal morbidity. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Meta-analysis was carried out using the hierarchical summary receiver operating characteristic (ROC) and the bivariate logit-normal (Reitsma) models. We identified 41 studies that met our inclusion criteria involving 112,034 patients in total. These included 11 prospective cohort studies (N = 9986), one randomized controlled trial (RCT) (N = 367), and 29 retrospective cohort studies (N = 101,681). The quality of the studies was variable, and only three studies blinded the ultrasound findings to the clinicians. Both EFW >4,000 g (or 90th centile for the gestational age) and AC >36 cm (or 90th centile) had >50% sensitivity for predicting macrosomia (birthweight above 4,000 g or 90th centile) at birth with positive likelihood ratios (LRs) of 8.74 (95% confidence interval [CI] 6.84-11.17) and 7.56 (95% CI 5.85-9.77), respectively. There was significant heterogeneity at predicting macrosomia, which could reflect the different study designs, the characteristics of the included populations, and differences in the formulas used. An EFW >4,000 g (or 90th centile) had 22% sensitivity at predicting shoulder dystocia with a positive likelihood ratio of 2.12 (95% CI 1.34-3.35). There was insufficient data to analyze other markers of neonatal morbidity. CONCLUSIONS: In this study, we found that suspected LGA is strongly predictive of the risk of delivering a large infant in low- and mixed-risk populations. However, it is only weakly (albeit statistically significantly) predictive of the risk of shoulder dystocia. There was insufficient data to analyze other markers of neonatal morbidity.

来源:PLoS Med,查看原文。版权归原作者所有。

引用

  1. Moraitis AA, Shreeve N, Sovio U, et al. Universal third-trimester ultrasonic screening using fetal macrosomia in the prediction of adverse perinatal outcome: A systematic review and meta-analysis of diagnostic test accuracy. PLoS Med. 2020. PMID: 33048935. doi:10.1371/journal.pmed.1003190

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。