两种鼻塞CPAP PEEP水平治疗早产儿呼吸窘迫综合征的随机对照试验方案
本研究为随机多中心试验,计划纳入216例胎龄26+0至29+6周的早产儿,比较鼻塞CPAP治疗时高PEEP(6-8 cmH2O)与低PEEP(3-5 cmH2O)对呼吸窘迫综合征的疗效。主要结局为需要插管机械通气>1小时或达到预设CPAP失败标准。研究假设早期应用较高PEEP能更有效对抗未成熟肺的塌陷,从而改善CPAP疗效。
要点
- 比较鼻塞CPAP下高PEEP(6-8 cmH2O)与低PEEP(3-5 cmH2O)对早产儿RDS的疗效。
- 主要结局为插管机械通气>1小时或达到CPAP失败标准(FiO2>0.5超过1小时或pCO2≥70 mmHg)。
- PEEP水平根据FiO2需求在干预期间滴定,以维持氧合在目标范围。
核心结论
- 目前早产儿呼吸窘迫综合征鼻塞CPAP治疗的最佳PEEP水平尚未确定,本研究旨在比较两种PEEP水平的疗效。
研究设计与样本
- 随机多中心试验,计划纳入216例胎龄26+0至29+6周的早产儿,随机分配至高PEEP组(6-8 cmH2O)或低PEEP组(3-5 cmH2O)。
- 干预从新生儿复苏开始持续至生后120小时,PEEP水平根据FiO2需求滴定以维持氧合在目标范围。
关键数值与推荐
- 主要结局定义为需要插管机械通气>1小时,或未插管但达到以下任一CPAP失败标准:FiO2>0.5持续>1小时,或两次间隔至少2小时的血气分析pCO2≥70 mmHg。
- 高PEEP组PEEP水平为6-8 cmH2O,低PEEP组为3-5 cmH2O。
临床怎么用
- 研究结果将为早产儿鼻塞CPAP治疗中PEEP水平的选择提供证据,以改善CPAP疗效并减少呼吸机相关肺损伤。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Nasal continuous positive airway pressure (CPAP) applies positive end-expiratory pressure (PEEP) and has been shown to reduce the need for intubation and invasive mechanical ventilation in very low birth weight infants with respiratory distress syndrome. However, CPAP failure rates of 50% are reported in large randomized controlled trials. A possible explanation for these failure rates is the application of insufficient low levels of PEEP during nasal CPAP treatment to maintain adequate functional residual capacity shortly after birth. The optimum PEEP level to treat symptoms of respiratory distress in very low birth weight infants has not been assessed in clinical studies. The aim of the study is to compare two different PEEP levels during nasal CPAP treatment in preterm infants. METHODS: In this randomized multicenter trial, 216 preterm infants born at 26 + 0-29 + 6 gestational weeks will be allocated to receive a higher (6-8 cmH2O) or a lower (3-5 cmH2O) PEEP during neonatal resuscitation and the first 120 h of life. The PEEP level within each group will be titrated throughout the intervention based on the FiO2 (fraction of inspired oxygen concentration) requirements to keep oxygenation within the target range. The primary outcome is defined as the need for intubation and mechanical ventilation for > 1 h or being not ventilated but reaching one of the two pre-defined CPAP failure criteria (FiO2 > 0.5 for > 1 h or pCO2 ≥ 70 mmHg in two consecutive blood gas analyses at least 2 h apart). DISCUSSION: Based on available data from the literature, the optimum level of PEEP that most effectively treats respiratory distress syndrome in preterm infants is unknown, since the majority of large clinical trials applied a wide range of PEEP levels (4-8 cmH2O). The rationale for our study hypothesis is that the early application of a higher PEEP level will more effectively counteract the collapsing properties of the immature and surfactant-deficient lungs and that the level of inspired oxygen may serve as a surrogate marker to guide PEEP titration. Finding the optimum noninvasive continuous distending pressure during early nasal CPAP is required to improve CPAP efficacy and as a consequence to reduce the exposure to ventilator-induced lung injury and the incidence of chronic lung disease in this vulnerable population of very preterm infants. TRIAL REGISTRATION: drks.de DRKS00019940 . Registered on March 13, 2020.
引用
- Waitz M, Engel C, Schloesser R, et al. Application of two different nasal CPAP levels for the treatment of respiratory distress syndrome in preterm infants-"The OPTTIMMAL-Trial"-Optimizing PEEP To The IMMAture Lungs: study protocol of a randomized controlled trial. Trials. 2020. PMID: 32998769. doi:10.1186/s13063-020-04660-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。