文献速递临床试验与 GCP

疏水性聚氨酯与聚氨酯外周静脉置入中心静脉导管的比较:可行性随机对照试验结果

A comparison of hydrophobic polyurethane and polyurethane peripherally inserted central catheter: results from a feasibility randomized controlled trial.
PubMed 文献 · Trials · 2020-09-14

本研究为一项可行性随机对照试验,纳入111例成人患者,比较疏水性聚氨酯PICC(近端阀)与标准聚氨酯PICC(外夹)的可行性。除入选标准外,所有可行性结局均达成;PICC失败率干预组24%(13/55)、标准组22%(12/55)(p=0.820),每1000 PICC日失败率分别为16.3和18.4(p=0.755),平均留置时间分别为12天和8天。研究表明,调整入选标准后可在成人中开展PICC材料有效性试验。

要点

  • 可行性结局除入选标准外均达成,111例随机、106例(95%)置入分配导管。
  • PICC失败率两组相近(24% vs 22%,p=0.820),每1000 PICC日失败率无显著差异。
  • 需调整入选标准以纳入出院至家庭医院服务的患者,方可开展有效性试验。

核心结论

  • 在成人中开展PICC材料有效性试验是可行的,但需调整入选标准以纳入出院至家庭医院服务的患者。

研究设计与样本

  • 可行性随机对照试验(RCT),2017年5月至2018年2月进行,成人参与者n=111,随机分配至疏水性聚氨酯PICC(近端阀)组或聚氨酯PICC(外夹)组。

主要发现

  • 筛查338例,符合条件138例(41%),随机111例(80%),106例(95%)置入分配PICC。
  • 无患者退出研究,无缺失数据。
  • PICC失败率干预组24%(13/55),标准组22%(12/55),p=0.820。
  • 每1000 PICC日失败率干预组16.3,对照组18.4,p=0.755。
  • 平均留置时间干预组12天,对照组8天。

关键数值与推荐

  • 可行性结局除入选标准外均达成。

临床怎么用

  • 疏水性聚氨酯PICC与标准聚氨酯PICC在PICC失败率上未见显著差异,但需进一步有效性试验验证。

局限性

  • 本研究为可行性试验,样本量有限,主要目的为评估可行性而非疗效比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To evaluate the feasibility of an efficacy trial comparing a hydrophobic polyurethane peripherally inserted central catheter (PICC) with a standard polyurethane PICC. METHODS: This pilot randomised controlled trial (RCT) was conducted between May 2017 and February 2018. Adult participants (n = 111) were assigned to hydrophobic polyurethane PICC with proximal valve (intervention) or a polyurethane PICC with external clamp (standard care). Primary outcome was trial feasibility including PICC failure. Secondary outcomes were central line-associated bloodstream infection, local infection, occlusion, thrombosis, fracture and dislodgement, phlebitis, local or systemic allergic reaction, and PICC dwell time. RESULTS: All feasibility outcomes were achieved, apart from eligibility criteria. In total, 338 patients were screened, 138 were eligible (41%), and of these 111 were randomised (80%). Patients received the allocated PICC in 106 (95%) insertions. No patients withdrew from the study and there was no missing data. PICC failure was 24% (13/55) in the intervention group and 22% (12/55) in the standard care group (p = 0.820). PICC failure per 1000 PICC days was 16.3 in the intervention group and 18.4 in the control group (p = 0.755). The average dwell time was 12 days in the intervention and 8 days in the control group. CONCLUSIONS: This study demonstrates the feasibility of an efficacy trial of PICC materials in an adult population, once adjustments were made to include not only in-patients, but also patients being discharged to the Hospital in the Home service. TRIAL REGISTRATION: Australia and New Zealand Clinical Trials Registry ACTRN12616001578493 . Prospectively registered on 16 November 2016. The trial protocol was published a priori (Kleidon et al., Vasc Access 3:15-21, 2017).

来源:Trials,查看原文。版权归原作者所有。

引用

  1. Gavin NC, Kleidon TM, Larsen E, et al. A comparison of hydrophobic polyurethane and polyurethane peripherally inserted central catheter: results from a feasibility randomized controlled trial. Trials. 2020. PMID: 32928286. doi:10.1186/s13063-020-04699-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。