文献速递流行病学与生物统计真实世界研究与卫生经济

卒中预测模型在透析患者中外部验证表现不佳的系统综述

A systematic review and external validation of stroke prediction models demonstrates poor performance in dialysis patients.
PubMed 文献 · J Clin Epidemiol · 2020-03-30

随访2.5年期间127例(6.5%)发生缺血性卒中,所有模型校准度差且区分度低(c统计量0.49-0.66),提示现有模型不适用于该脆弱人群。

要点

  • 15个卒中预测模型在起始透析患者中外部验证均表现不佳。
  • 所有模型存在高偏倚风险,校准度差,c统计量仅0.49-0.66。
  • Framingham模型校准度尚可但区分度差,c统计量0.57(95%CI 0.50-0.63)。

核心结论

  • 外部验证显示缺血性卒中预测模型在起始透析患者中预测性能弱,不建议直接使用。
  • 建议更新现有模型或开发并验证适用于该人群的新模型。

研究设计与样本

  • 系统综述与外部验证研究,由两名评审员系统检索并筛选缺血性卒中模型。
  • 采用PROBAST评估偏倚风险,在NECOSAD前瞻性多中心起始透析队列(1,955例)中评估预测性能。
  • 计算c统计量评估区分度,通过绘制预测与观察卒中概率及校准-in-the-large评估校准度。

主要发现

  • 所有验证模型在一个或多个领域存在高偏倚风险。
  • NECOSAD队列1,955例患者中,随访2.5年期间127例(6.5%)发生缺血性卒中。
  • 与原始研究相比,多数模型表现更差,所有模型校准度差且区分度低(c统计量0.49-0.66)。
  • Framingham模型校准度尚可,但c统计量0.57(95%CI 0.50-0.63),区分度差。

临床怎么用

  • 临床不应直接在起始透析患者中使用现有缺血性卒中预测模型进行风险分层。
  • 需更新现有模型或开发针对透析人群的新预测模型并外部验证后再用于临床。

局限性

  • 所有验证模型存在高偏倚风险,可能影响预测性能评估的可靠性。
  • 外部验证仅在NECOSAD单一队列中进行,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The objective of this study was to systematically review and externally assess the predictive performance of models for ischemic stroke in incident dialysis patients. STUDY DESIGN AND SETTING: Two reviewers systematically searched and selected ischemic stroke models. Risk of bias was assessed with the PROBAST. Predictive performance was evaluated within The Netherlands Cooperative Study on the Adequacy of Dialysis (NECOSAD), a large prospective multicenter cohort of incident dialysis patients. For discrimination, c-statistics were calculated; calibration was assessed by plotting predicted and observed probabilities for stroke, and calibration-in-the-large. RESULTS: Seventy-seven prediction models for stroke were identified, of which 15 were validated. Risk of bias was high, with all of these models scoring high risk in one or more domains. In NECOSAD, of the 1,955 patients, 127 (6.5%) suffered an ischemic stroke during the follow-up of 2.5 years. Compared with the original studies, most models performed worse with all models showing poor calibration and discriminative abilities (c-statistics ranging from 0.49 to 0.66). The Framingham showed reasonable calibration; however, with a c-statistic of 0.57 (95% CI 0.50-0.63), the discrimination was poor. CONCLUSION: This external validation demonstrates the weak predictive performance of ischemic stroke models in incident dialysis patients. Instead of using these models in this fragile population, either existing models should be updated, or novel models should be developed and validated.

来源:J Clin Epidemiol,查看原文。版权归原作者所有。

引用

  1. de Jong Y, Ramspek CL, van der Endt VHW, et al. A systematic review and external validation of stroke prediction models demonstrates poor performance in dialysis patients. J Clin Epidemiol. 2020. PMID: 32240769. doi:10.1016/j.jclinepi.2020.03.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。