温度控制衬垫材料对下肢假肢长期使用效果的影响:随机对照试验方案
本研究为双盲纵向交叉随机对照试验方案,纳入胫骨假肢使用者,随机顺序分别佩戴常规凝胶或硅胶衬垫与相变材料衬垫各六个月,通过活动监测器和标准化方法每六周评估活动、体能和假肢整体评价,旨在探究相变材料衬垫长期使用是否具有临床意义。
要点
- 相变材料衬垫可能降低假肢接受腔内温度及升温速度,但临床相关性尚不明确。
- 试验采用双盲交叉设计,比较常规衬垫与相变材料衬垫各六个月使用效果。
- 结果可为相变材料衬垫的处方与报销实践提供高级别循证依据。
核心结论
- 尚不明确相变材料温度控制衬垫长期使用是否具有临床意义,本试验旨在回答该问题。
研究设计与样本
- 双盲纵向交叉随机对照试验方案,受试者为胫骨假肢使用者。
- 受试者随机顺序佩戴常规凝胶或硅胶衬垫六个月和相变材料衬垫六个月。
- 假肢配备活动监测器以检测无法佩戴假肢的天数。
- 每六周采用标准化方法记录活动、体能和假肢整体评估。
临床怎么用
- 预期结果将用于指导相变材料衬垫的处方与报销实践。
- 有助于改善和节约截肢者的假肢适配。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In people living with limb loss, addressing the resulting functional deficit with prostheses increases the risk for secondary conditions such as pressure sores, impaired blood perfusion, and injuries from accidental falls. Any of those occurrences can render the prosthesis temporarily useless, making it challenging for users to engage in many activities of daily life, including work, exercise, and social participation. Many of the described issues originate at the interface between residual limb and prosthetic socket, where the objectives of sufficient weight distribution and suspension are conflicting with the necessity to facilitate heat exchange and limit contact pressure and friction. Recently, prosthesis liners that contain phase-change material have become commercially available, holding the promise that the micro climate at the interface between the residual limb skin and the prosthetic socket can be regulated to reduce the users' tendency to sweat. Preliminary studies on these liners indicate that the socket temperatures inside the socket stayed lower and rose slower than in conventional liners. However, the clinical relevance of those findings remains unclear. The purpose of this study is to investigate whether longer (6+ months) periods of use of phase-change material based temperature-control liners have clinically meaningful effects. METHODS: The protocol is a double-blind longitudinal cross-over research design. A sample of trans-tibial prosthesis users are wearing their regular gel or silicone liners for six months and phase-change material liners for another six months in a randomized sequence. Their prostheses is equipped with activity monitors to detect days when they could not wear their prosthesis. In six-week intervals, individuals' activity, physical performance, and overall prosthesis assessment is recorded using standardized methods. DISCUSSION: Expected results will inform prescription and reimbursement practice of phase-change material-based prosthesis liners and will help improve and economize prosthetic fitting for people with limb loss. The design and duration of the protocol, including randomization, blinding, and within-subject comparison, will generate scientific evidence of a comparably high level. Inclusion of a comparably large sample and different climates, e.g. across all four seasons, will make findings applicable to a large number of prosthesis users. TRIAL REGISTRATION: Clinicaltrials.gov, NCT03428815. Registered on 12 February 2018.
引用
- Fiedler G, Singh A, Zhang X, et al. Effect of temperature-control liner materials on long-term outcomes of lower limb prosthesis use: a randomized controlled trial protocol. Trials. 2020. PMID: 31924257. doi:10.1186/s13063-019-3920-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。