文献速递流行病学与生物统计基础与转化研究

危重成人颅内压升高诊断:系统综述与荟萃分析

Diagnosis of elevated intracranial pressure in critically ill adults: systematic review and meta-analysis.
PubMed 文献 · BMJ · 2019-07-24

该系统综述与荟萃分析纳入40项研究(n=5123),比较体格检查、CT、视神经鞘直径超声和经颅多普勒搏动指数对危重患者颅内压升高的诊断准确性。结果显示单项体格检查特征缺失不足以排除颅内压升高,中线移位可提示但不能排除,视神经鞘超声可能有用但需进一步研究。

要点

  • 瞳孔散大诊断颅内压升高的汇总敏感度28.2%、特异度85.9%。
  • 基底池受压的CT敏感度85.9%、特异度61.0%。
  • 视神经鞘直径超声的汇总AUROC为0.94。

核心结论

  • 任一单项体格检查特征缺失均不足以排除颅内压升高。
  • 明显中线移位可提示颅内压升高,但无移位不能排除。
  • 视神经鞘超声可能有用,但需进一步研究。
  • 怀疑颅内压升高时,无论单项无创检查结果如何,可能需治疗和转运。

研究设计与样本

  • 系统综述与荟萃分析,检索Medline、EMBASE、PubMed等六个数据库至2018年9月1日。
  • 纳入40项研究,共5123例危重患者。
  • 参考标准为有创颅内压监测≥20 mm Hg或术中诊断颅内压升高。

主要发现

  • 瞳孔散大诊断颅内压升高的汇总敏感度28.2%(95%CI 16.0%–44.8%),特异度85.9%(74.9%–92.5%)。
  • 去大脑强直姿势的汇总敏感度54.3%(36.6%–71.0%),特异度63.6%(46.5%–77.8%)。
  • 格拉斯哥昏迷评分≤8分的汇总敏感度75.8%(62.4%–85.5%),特异度39.9%(26.9%–54.5%)。
  • 基底池受压的CT汇总敏感度85.9%(58.0%–96.4%),特异度61.0%(29.1%–85.6%)。
  • 视神经鞘直径超声的汇总AUROC为0.94(0.91–0.96)。

关键数值与推荐

  • 瞳孔散大:敏感度28.2%(95%CI 16.0%–44.8%),特异度85.9%(74.9%–92.5%)。
  • 去大脑强直姿势:敏感度54.3%(36.6%–71.0%),特异度63.6%(46.5%–77.8%)。
  • 格拉斯哥昏迷评分≤8分:敏感度75.8%(62.4%–85.5%),特异度39.9%(26.9%–54.5%)。
  • 基底池受压:敏感度85.9%(58.0%–96.4%),特异度61.0%(29.1%–85.6%)。
  • 视神经鞘直径超声:汇总AUROC 0.94(0.91–0.96)。

临床怎么用

  • 不能仅凭任一单项体格检查特征缺失排除颅内压升高。
  • 明显中线移位可提示颅内压升高,但无移位不能排除。
  • 视神经鞘超声可能辅助评估,但需进一步研究验证。
  • 怀疑颅内压升高时,无论单项无创检查结果如何,可能需治疗和转运。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To summarise and compare the accuracy of physical examination, computed tomography (CT), sonography of the optic nerve sheath diameter (ONSD), and transcranial Doppler pulsatility index (TCD-PI) for the diagnosis of elevated intracranial pressure (ICP) in critically ill patients. DESIGN: Systematic review and meta-analysis. DATA SOURCES: Six databases, including Medline, EMBASE, and PubMed, from inception to 1 September 2018. STUDY SELECTION CRITERIA: English language studies investigating accuracy of physical examination, imaging, or non-invasive tests among critically ill patients. The reference standard was ICP of 20 mm Hg or more using invasive ICP monitoring, or intraoperative diagnosis of raised ICP. DATA EXTRACTION: Two reviewers independently extracted data and assessed study quality using the quality assessment of diagnostic accuracy studies tool. Summary estimates were generated using a hierarchical summary receiver operating characteristic (ROC) model. RESULTS: 40 studies (n=5123) were included. Of physical examination signs, pooled sensitivity and specificity for increased ICP were 28.2% (95% confidence interval 16.0% to 44.8%) and 85.9% (74.9% to 92.5%) for pupillary dilation, respectively; 54.3% (36.6% to 71.0%) and 63.6% (46.5% to 77.8%) for posturing; and 75.8% (62.4% to 85.5%) and 39.9% (26.9% to 54.5%) for Glasgow coma scale of 8 or less. Among CT findings, sensitivity and specificity were 85.9% (58.0% to 96.4%) and 61.0% (29.1% to 85.6%) for compression of basal cisterns, respectively; 80.9% (64.3% to 90.9%) and 42.7% (24.0% to 63.7%) for any midline shift; and 20.7% (13.0% to 31.3%) and 89.2% (77.5% to 95.2%) for midline shift of at least 10 mm. The pooled area under the ROC (AUROC) curve for ONSD sonography was 0.94 (0.91 to 0.96). Patient level data from studies using TCD-PI showed poor performance for detecting raised ICP (AUROC for individual studies ranging from 0.55 to 0.72). CONCLUSIONS: Absence of any one physical examination feature is not sufficient to rule out elevated ICP. Substantial midline shift could suggest elevated ICP, but the absence of shift cannot rule it out. ONSD sonography might have use, but further studies are needed. Suspicion of elevated ICP could necessitate treatment and transfer, regardless of individual non-invasive tests. REGISTRATION: PROSPERO CRD42018105642.

来源:BMJ,查看原文。版权归原作者所有。

引用

  1. Fernando SM, Tran A, Cheng W, et al. Diagnosis of elevated intracranial pressure in critically ill adults: systematic review and meta-analysis. BMJ. 2019. PMID: 31340932. doi:10.1136/bmj.l4225

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。