文献速递临床试验与 GCP基础与转化研究

两种干骺端适配短型股骨柄在初次全髋关节置换术中的比较:前瞻性随机临床试验研究方案及附加生物力学测试与有限元分析

Comparison of two metaphyseal-fitting (short) femoral stems in primary total hip arthroplasty: study protocol for a prospective randomized clinical trial with additional biomechanical testing and finite element analysis.
PubMed 文献 · Trials · 2019-06-17

本研究方案拟通过生物力学测试与有限元分析,结合前瞻性随机临床试验,比较新型短柄Minima S与旧一代Trilock Bone Preservation Stem在初次全髋关节置换术中的生物力学特性与临床性能,随访至2年,评估临床评分、步态分析、影像学固定与 remodeling 及并发症。

要点

  • 研究比较两种干骺端适配短柄的生物力学与临床性能
  • 临床试验前瞻性随机,随访至2年,评估临床评分、步态分析、影像学及并发症
  • 生物力学测试采用数字图像相关技术及有限元分析辅助比较

核心结论

  • 研究假设两种短柄几何设计的细微差异可能产生不同负荷特征和生物力学行为,进而影响临床性能。

研究设计与样本

  • 实验研究:在非植入股骨和植入股骨上,用数字图像相关技术测量股骨近端皮质表面应变分布,并建立骨、柄及界面的有限元参数模型。
  • 临床研究:前瞻性随机对照临床试验,比较两种短柄,随访至2年。

主要发现

  • 原文未报告结果。

关键数值与推荐

  • 临床性能评估:采用临床评分和步态分析,随访至2年。
  • 柄固定与重塑评估:采用详细影像学分析。
  • 并发症评估:记录并发症发生率和类型。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total hip replacement has recently followed a progressive evolution towards principles of bone- and soft-tissue-sparing surgery. Regarding femoral implants, different stem designs have been developed as an alternative to conventional stems, and there is a renewed interest towards short versions of uncemented femoral implants. Based on both experimental testing and finite element modeling, the proposed study has been designed to compare the biomechanical properties and clinical performance of the newly introduced short-stem Minima S, for which clinical data are lacking with an older generation stem, the Trilock Bone Preservation Stem with an established performance record in short to midterm follow-up. METHODS/DESIGN: In the experimental study, the transmission of forces as measured by cortical surface-strain distribution in the proximal femur will be evaluated using digital image correlation (DIC), first on the non-implanted femur and then on the implanted stems. Finite element parametric models of the bone, the stem and their interface will be also developed. Finite element predictions of surface strains in implanted composite femurs, after being validated against biomechanical testing measurements, will be used to assist the comparison of the stems by deriving important data on the developed stress and strain fields, which cannot be measured through biomechanical testing. Finally, a prospective randomized comparative clinical study between these two stems will be also conducted to determine (1) their clinical performance up to 2 years' follow-up using clinical scores and gait analysis (2) stem fixation and remodeling using a detailed radiographic analysis and (3) incidence and types of complications. DISCUSSION: Our study would be the first that compares not only the clinical and radiological outcome but also the biomechanical properties of two differently designed femoral implants that are theoretically classified in the same main category of cervico-metaphyseal-diaphyseal short stems. We can hypothesize that even these subtle variations in geometric design between these two stems may create different loading characteristics and thus dissimilar biomechanical behaviors, which in turn could have an influence to their clinical performance. TRIAL REGISTRATION: International Standard Randomized Controlled Trial Number, ID: ISRCTN10096716 . Retrospectively registered on May 8 2018.

来源:Trials,查看原文。版权归原作者所有。

引用

  1. Tatani I, Panagopoulos A, Diamantakos I, et al. Comparison of two metaphyseal-fitting (short) femoral stems in primary total hip arthroplasty: study protocol for a prospective randomized clinical trial with additional biomechanical testing and finite element analysis. Trials. 2019. PMID: 31208433. doi:10.1186/s13063-019-3445-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。