机械循环支持装置与心脏的滞回交互可预测左室舒张末压

Mechanical circulatory support device-heart hysteretic interaction can predict left ventricular end diastolic pressure.
PubMed 文献 · Sci Transl Med · 2018-01-01

研究利用经皮心室辅助装置的位置和先进数据分析方法,从装置的滞回运行指标中获取左室舒张末压(LVEDP)。通过模拟流环路、心脏功能障碍动物模型和心源性休克患者数据验证,该滞回推导的LVEDP测量比传统经肺毛细血管楔压(PCWP)推断更精确且与实际压力相关性更好。

要点

  • 装置滞回指标可无创推导LVEDP,精度优于PCWP推断。
  • 在模拟环路、动物模型和患者数据中验证了该方法。
  • 为连续评估心脏状态和闭环自动控制提供新思路。

核心结论

  • 机械循环支持装置与心脏的滞回交互可用于预测左室舒张末压,且比经PCWP推断更精确。

研究设计与样本

  • 研究利用经皮心室辅助装置的位置和先进数据分析方法获取LVEDP,并在模拟流环路、心脏功能障碍动物模型和心源性休克患者数据中验证。

主要发现

  • 滞回推导的LVEDP测量在模拟流环路、动物模型和患者数据中均显示出比传统经PCWP推断更高的测量精度和与实际压力的更好相关性。

临床怎么用

  • 该技术有望用于连续评估心脏状态和功能指标,并支持闭环自动控制及未来机械循环支持系统的合理设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The full potential of mechanical circulatory systems in the treatment of cardiogenic shock is impeded by the lack of accurate measures of cardiac function to guide clinicians in determining when to initiate and how to optimally titrate support. The left ventricular end diastolic pressure (LVEDP) is an established metric of cardiac function that refers to the pressure in the left ventricle at the end of ventricular filling and immediately before ventricular contraction. In clinical practice, LVEDP is typically only inferred from, and poorly correlates with, the pulmonary capillary wedge pressure (PCWP). We leveraged the position of an indwelling percutaneous ventricular assist device and advanced data analysis methods to obtain LVEDP from the hysteretic operating metrics of the device. We validated our hysteresis-derived LVEDP measurement using mock flow loops, an animal model of cardiac dysfunction, and data from a patient in cardiogenic shock to show greater measurement precision and correlation with actual pressures than traditional inferences via PCWP. Delineation of the nonlinear relationship between device and heart adds insight into the interaction between ventricular support devices and the native heart, paving the way for continuous assessment of underlying cardiac state, metrics of cardiac function, potential closed-loop automated control, and rational design of future innovations in mechanical circulatory support systems.

来源:Sci Transl Med,查看原文。版权归原作者所有。