文献速递流行病学与生物统计医学人工智能与信息学

一种新的统计模型分析系统评价数据生成用于哮喘诊断的呼出气一氧化氮最佳截断值

A novel statistical model for analyzing data of a systematic review generates optimal cutoff values for fractional exhaled nitric oxide for asthma diagnosis.
PubMed 文献 · J Clin Epidemiol · 2017-09-12

该研究重新分析了一项系统评价中26项研究共4518名参与者的数据,采用多重阈值模型评估呼出气一氧化氮(FENO)诊断哮喘的最佳截断值。结果显示,当哮喘验前概率至少30%时,FENO>50 ppb的阳性预测值为0.76(95%CI 0.29-0.96);当验前概率至多30%时,FENO<20 ppb的阴性预测值为0.86(95%CI 0.66-0.95)。多重阈值模型能更全面、更临床有用呈现不同阈值的效果,有助于确定FENO诊断或排除哮喘的最佳阈值。

要点

  • 当哮喘验前概率至少30%时,FENO>50 ppb的阳性预测值为0.76(95%CI 0.29-0.96)。
  • 当哮喘验前概率至多30%时,FENO<20 ppb的阴性预测值为0.86(95%CI 0.66-0.95)。
  • 多重阈值模型可更全面、更临床有用呈现不同阈值效果,有助于确定最佳阈值。

核心结论

  • 多重阈值模型能更全面、更临床有用呈现不同阈值效果,有助于确定FENO诊断或排除哮喘的最佳阈值。

研究设计与样本

  • 重新分析一项系统评价的数据,该系统评价研究FENO测量诊断哮喘的准确性;共纳入26项研究、4518名参与者,提取150个数据集、53种不同截断值,采用多重阈值模型分析。

主要发现

  • 当哮喘验前概率至少30%时,FENO>50 ppb的阳性预测值为0.76(95%CI 0.29-0.96)。
  • 当哮喘验前概率至多30%时,FENO<20 ppb的阴性预测值为0.86(95%CI 0.66-0.95)。

关键数值与推荐

  • FENO>50 ppb在验前概率至少30%时阳性预测值为0.76(95%CI 0.29-0.96)。
  • FENO<20 ppb在验前概率至多30%时阴性预测值为0.86(95%CI 0.66-0.95)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Measurement of fractional exhaled nitric oxide (FENO) might substitute bronchial provocation for diagnosing asthma. However, optimal FENO thresholds for diagnosing asthma remain unclear. We reanalyzed data collected for a systematic review investigating the diagnostic accuracy of FENO measurement to exploit all available thresholds under consideration of pretest probabilities using a newly developed statistical model. STUDY DESIGN AND SETTING: One hundred and fifty data sets for a total of 53 different cutoffs extracted from 26 studies with 4,518 participants were analyzed with the multiple thresholds model. This model allows identifying thresholds at which the test is likely to perform best. RESULTS: Diagnosing asthma might only be possible in a meaningful manner when the pretest probability of asthma is at least 30%. In that case, FENO > 50 ppb leads to a positive predictive value of 0.76 [95% confidence interval (CI): 0.29-0.96]. Excluding asthma might only be possible, when the pretest probability of asthma is 30% at maximum. Then, FENO < 20 ppb leads to a negative predictive value of 0.86 (95% CI 0.66-0.95). CONCLUSION: The multiple thresholds model generates a more comprehensive and more clinically useful picture of the effects of different thresholds, which facilitates the determination of optimal thresholds for diagnosing or excluding asthma with FENO measurement.

来源:J Clin Epidemiol,查看原文。版权归原作者所有。

引用

  1. Schneider A, Linde K, Reitsma JB, et al. A novel statistical model for analyzing data of a systematic review generates optimal cutoff values for fractional exhaled nitric oxide for asthma diagnosis. J Clin Epidemiol. 2017. PMID: 28916487. doi:10.1016/j.jclinepi.2017.09.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。