文献速递基础与转化研究临床试验与 GCP

人类皮层内微刺激的长期安全性与有效性

Long-term safety and efficacy of intracortical microstimulation in humans.
PubMed 文献 · Sci Transl Med · 2026-07-15

该早期可行性临床试验评估了感觉皮层ICMS在5名脊髓损伤参与者中的安全性、有效性和持久性,每人在Brodmann 1区手部代表区植入两个Blackrock NeuroPort微电极阵列。

要点

  • ICMS持续诱发定位于手部的感觉,阈值每年约增3.5微安。
  • 64±13%电极仍可靠诱发触觉,一例10年后仍有60%电极有效。

核心结论

  • 将ICMS递送至感觉皮层是安全有效的,可长达10年持续诱发信息性躯体感觉,展示ICMS用于感觉恢复的临床前景。

研究设计与样本

  • 早期可行性临床试验(NCT01894802),纳入5名脊髓损伤参与者,每人植入两个Blackrock NeuroPort微电极阵列于Brodmann 1区手部代表区。
  • 植入时长跨度2至10年,累计植入时长27年。

主要发现

  • ICMS持续诱发定位于手部的感觉;罕见情况下刺激停止后感觉短暂持续(参与者间3至25次事件)。
  • ICMS检测阈值随时间缓慢增加,约每年3.5微安。
  • 64±13%的电极仍可靠诱发触觉感觉(功能性电极约减少21%),其中一名参与者在10年后仍有60%的电极有效。
  • ICMS诱发感觉的质量和投射野覆盖均保持一致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Intracortical microstimulation (ICMS) of somatosensory cortex can restore a sense of touch to people with spinal cord injury. In this early feasibility clinical trial (NCT01894802), we evaluated the safety, efficacy, and longevity of ICMS because there is a paucity of such long-term studies in humans. This information is crucial to the development of clinical neuromodulation devices, particularly for restoring touch, hearing, and vision. ICMS was delivered to five participants with spinal cord injury who were each implanted with two Blackrock NeuroPort microelectrode arrays in the hand representation of Brodmann's area 1. Across implant durations spanning 2 to 10 years, we measured single-electrode detection thresholds, projected fields, quality reports, and electrode health characteristics. ICMS-related adverse events were documented throughout. More than 168 million ICMS pulses were delivered across a combined implant duration of 27 years without any serious adverse events or direct negative effects on electrode health. ICMS consistently evoked sensations localized to the hand. Rarely, sensations persisted for brief periods after stimulation offset (3 to 25 events across participants). ICMS detection thresholds increased slowly over time (about 3.5 microamperes per year), but 64 ± 13% of the electrodes still reliably evoked tactile sensations (about 21% decrease in functional electrodes), including 60% of the electrodes after 10 years in one participant. The quality and projected field coverage of ICMS-evoked sensations were both consistent. Delivering ICMS to the somatosensory cortex was safe and effective, consistently evoking informative somatosensory percepts as long as 10 years, demonstrating the clinical promise of ICMS for sensory restoration.

来源:Sci Transl Med,查看原文。版权归原作者所有。

引用

  1. Greenspon CM, Hobbs TG, Verbaarschot C, et al. Long-term safety and efficacy of intracortical microstimulation in humans. Sci Transl Med. 2026. PMID: 42455900. doi:10.1126/scitranslmed.aec3728