文献速递临床试验与 GCP基础与转化研究

重复经颅磁刺激对卒中后上肢功能障碍脑电图指标的影响:随机对照试验研究方案

Effects of repetitive transcranial magnetic stimulation on electroencephalographical measures of poststroke upper limb dysfunction: study protocol for a randomized controlled trial.
PubMed 文献 · Trials · 2026-03-16

本研究为随机对照试验方案,拟纳入42例卒中后上肢功能障碍患者,按1:1随机分为高频与低频rTMS组。高频组于患侧M1以90%RMT、10Hz、共1500脉冲治疗2周,低频组于健侧M1以1Hz相同参数治疗。将在基线和rTMS后1周内评估NIHSS、FMA-UE、MBI及静息态EEG,以探讨两种频率rTMS的临床疗效及脑神经生理机制。

要点

  • 42例卒中后上肢功能障碍患者随机分为高频与低频rTMS组。
  • 高频组患侧M1 10Hz、90%RMT、1500脉冲,低频组健侧M1 1Hz。
  • 结局包括NIHSS、FMA-UE、MBI及静息态EEG,基线与治疗后1周内评估。

核心结论

  • 本方案旨在探讨高频与低频rTMS对卒中后上肢功能障碍患者从皮层振荡活动到复杂网络效应的脑神经生理机制变化。

研究设计与样本

  • 随机对照试验方案,共42例卒中后上肢功能障碍患者按1:1随机分为高频rTMS组和低频rTMS组。

关键数值与推荐

  • 高频rTMS组:90%静息运动阈值(RMT),10Hz作用于患侧M1,共1500脉冲,持续2周。
  • 低频rTMS组:作用于健侧M1,参数除频率为1Hz外与高频组相同。
  • 评估工具包括NIHSS、FMA-UE、MBI和静息态EEG,于基线和rTMS后1周内获取。

临床怎么用

  • 该方案为卒中后上肢功能障碍的rTMS参数选择及疗效评估提供了随机对照研究框架,结果待试验完成后可指导临床决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients with stroke would experience upper limb dysfunction, leading to functional impairments in daily living and placing a burden on society and families. Repetitive transcranial magnetic stimulation (rTMS), a noninvasive neuromodulation tool, has been shown to upper limb dysfunction. However, the clinical efficacy and the underlying neurophysiological mechanisms of optimal intensity of rTMS to promote motor recovery of stroke patients with upper limb function need further investigations. This study aims to investigate the changes in the brain neurophysiological mechanisms ranging from cortical oscillatory activity to the effectiveness of the complex network after low-frequency (LF) and high-frequency (HF) rTMS on motor areas of patient post-stroke. METHOD: A total of 42 stroke patients with upper limb dysfunction will be randomized into high-frequency (HF) rTMS group and low-frequency (LF) rTMS group (1:1 ratio). The HF-rTMS group will use 90% resting motor threshold (RMT), 10 Hz acting with the ipsilesional M1 for a total of 1500 pulses for 2 weeks, and the LF-rTMS group acting on the contralesional M1 with the same parameters, except that 1 Hz is used. The National Institutes of Health Stroke Scale (NIHSS), the motor deficit (the Fugl-Meyer Assessment Upper Extremity (FMA-UE)), Modified Barthel Index (MBI), and resting-state electroencephalogram (EEG) signals will be obtained at the baseline and within 1 week after the rTMS. DISCUSSION: This study will contribute to the understanding of the neurophysiological changes in the brain corresponding to the clinical effects of HF- and LF-rTMS in patients with stroke. TRIAL REGISTRATION: ChiCTR2200065639. Registered in November 2022.

来源:Trials,查看原文。版权归原作者所有。

引用

  1. Chen B, Wu HM, Chan SCC, et al. Effects of repetitive transcranial magnetic stimulation on electroencephalographical measures of poststroke upper limb dysfunction: study protocol for a randomized controlled trial. Trials. 2026. PMID: 41840671. doi:10.1186/s13063-026-09627-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。