呼吸气体变化延迟关键雪崩掩埋中的窒息:一项随机临床试验
这项由4家机构组织、在意大利1个野外场地进行的随机盲法临床试验,纳入健康志愿者进行关键雪崩掩埋模拟,比较Safeback SBX安全装置与假装置。结果显示,安全装置组血氧饱和度低于80%的事件风险显著低于对照组,且空气囊内二氧化碳更低、氧气更高,可延迟关键低氧血症和高碳酸血症。
要点
- 安全装置组掩埋中位时间35.0分钟且无事件,对照组中位6.4分钟且发生7起事件。
- 安全装置组因血氧饱和度低于80%终止的风险显著更低(P < .001)。
- 同一位置空气囊二氧化碳安全装置组1.3% vs 对照组6.1%,氧气19.8% vs 12.4%。
核心结论
- 一种无需补充氧气或咬嘴、由用户携带的雪崩安全装置,可将雪崩碎屑中的气流输送至使用者气道,在模拟关键掩埋中延迟关键低氧血症和高碳酸血症。
研究设计与样本
- 随机、盲法临床试验,由4家机构组织,在意大利1个野外场地于2023年1月至3月进行,纳入18至60岁健康志愿者。
- 参与者随机分为安全装置组(使用Safeback SBX装置)或对照组(使用假装置),在俯卧位、覆盖至少50 cm积雪条件下进行关键雪崩掩埋模拟,持续监测生命体征。
- 安全装置组完成一次非盲对照,即掩埋35分钟后仍处于掩埋状态的参与者无缝转换为假装置。
- 36名随机参与者中,24名完成试验并纳入最终分析;中位(IQR)年龄27(25-32)岁,13名(54%)为男性。
主要发现
- 安全装置组中位(IQR)掩埋时间为35.0(35.0-35.0)分钟且无事件;对照组中位(IQR)掩埋时间为6.4(4.8-13.5)分钟且发生7起事件。
- 安全装置组因血氧饱和度低于80%终止的风险显著更低(对数秩检验和Breslow检验P均 < .001)。
- 同一位置空气囊二氧化碳浓度:安全装置组1.3%(95% CI,1.0%-1.6%)vs 对照组6.1%(95% CI,5.1%-7.1%)。
- 同一位置氧气浓度:安全装置组19.8%(95% CI,19.5%-20.1%)vs 对照组12.4%(95% CI,11.2%-13.5%)。
关键数值与推荐
- 主要结局为35分钟监测期间血氧饱和度低于80%的时间,比较干预组与对照组。
- 次要结局包括不同雪距处的氧气和二氧化碳浓度。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: People who are critically buried by an avalanche typically die of asphyxia within 35 minutes, often making timely rescue impossible. The development of new strategies to delay asphyxiation is crucial to improve survival rates. OBJECTIVE: To investigate the efficacy of a novel, user-carried avalanche safety device that delivers airflow from avalanche debris to the user's airway without requiring supplemental oxygen or a mouthpiece. DESIGN, SETTING, AND PARTICIPANTS: This randomized, blinded, clinical trial was organized by 4 institutions and conducted at 1 field location in Italy from January to March 2023. Healthy volunteers aged 18 to 60 years were enrolled. Trial participants underwent a critical snow burial simulation while in a prone position covered by at least 50 cm of snow. Vital parameters were continuously monitored throughout the simulation to ensure participant safety and to collect physiological data. INTERVENTIONS: Participants were randomized to the safety device group (using the Safeback SBX device) or the control group (using a sham device). The safety device group completed an unblinded control in which the participants who remained buried after 35 minutes were seamlessly transferred to the sham device. MAIN OUTCOMES AND MEASURES: The primary outcome measure was the time to oxygen saturation as measured by pulse oximetry (Spo2) less than 80% (event) during 35 minutes of monitoring, comparing intervention and control groups. Secondary outcomes included oxygen and carbon dioxide concentrations at different distances in the snow. RESULTS: Of 36 randomized participants, 24 performed and completed the trial and were included in the final analysis. The median (IQR) age was 27 (25-32) years, and 13 (54%) were male. In the safety device group, the median (IQR) burial duration was 35.0 (35.0-35.0) minutes and there were no events; in the control group, the median (IQR) burial duration was 6.4 (4.8-13.5) minutes and there were 7 events. The safety device group had a significantly lower risk of termination due to Spo2 less than 80% (P < .001 for both log-rank and Breslow tests). Carbon dioxide in the air pocket was 1.3% (95% CI, 1.0%-1.6%) vs 6.1% (95% CI, 5.1%-7.1%) and oxygen was 19.8% (95% CI, 19.5%-20.1%) vs 12.4% (95% CI, 11.2%-13.5%) at the same points in the safety device and control groups, respectively. CONCLUSIONS AND RELEVANCE: A user-carried avalanche safety device that delivers airflow from avalanche debris to the user's airways without requiring supplemental oxygen delayed critical hypoxemia and hypercapnia during simulated critical burial. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05779540.
引用
- Eisendle F, Roveri G, Rauch S, et al. Respiratory Gas Shifts to Delay Asphyxiation in Critical Avalanche Burial: A Randomized Clinical Trial. JAMA. 2025. PMID: 41060661. doi:10.1001/jama.2025.16837
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。