文献速递流行病学与生物统计医学教育与科研方法

孕产妇早期预警评分方法学薄弱且偏倚风险高

Maternal early warning scores shown to be methodologically weak and at high risk of bias.
PubMed 文献 · J Clin Epidemiol · 2025-05-19

该系统综述检索2000年1月1日至2022年12月31日发表的改良产科早期预警评分(MOEWS)研究,纳入20项研究,用PROBAST和TRIPOD进行批判性评估。结果显示数据驱动模型开发未充分处理重复测量和缺失数据,95%研究偏倚风险高,数据驱动模型均未独立验证,提示已发表评分在临床实践中可能表现不佳或有害。

要点

  • 20项MOEWS研究中,5项为模型开发、5项为开发加验证、10项仅验证。
  • 4项数据驱动开发研究未处理方法学挑战,6项开发研究基于临床共识。
  • 95%研究偏倚风险高,数据驱动模型均未独立验证。

核心结论

  • 缺乏遵循推荐统计指南开发的MOEWS,纳入的开发与验证研究方法学质量存在实质问题且偏倚风险高,提示已发表评分在临床实践中可能表现不佳或有害。
  • 未来工作应处理缺失数据和重复测量,并考虑MOEWS在不同人群和关键亚组中的表现。

研究设计与样本

  • 系统综述与批判性评估,检索Medline、CINAHL、EMBASE和Web of Science中2000年1月1日至2022年12月31日发表的MOEWS研究。
  • 纳入预测孕妇任何孕周至妊娠结束后1周内医院场景中孕产妇死亡、重症监护室(ICU)入院和/或两种及以上孕产妇疾病复合结局的模型研究。
  • 共纳入20项研究:5项(25%)为模型开发研究,5项(25%)为模型开发与验证,10项(50%)仅为验证。
  • 使用预测模型偏倚风险评估工具(PROBAST)和预测模型透明报告(TRIPOD)进行批判性评估。

主要发现

  • 4项开发研究使用统计方法,其余6项研究使用临床共识(即专家意见)。
  • 4项数据驱动模型开发研究未解决重复测量或缺失数据等关键统计挑战,也未充分评估性能或清晰描述数据集特征。
  • 除1项研究外,所有研究(95%)因数据来源、报告不佳和分析局限性被评为高偏倚风险。
  • 15项验证研究报告不佳,其中11项(73%)为高偏倚风险。
  • 数据驱动模型均未进行独立验证。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To systematically review and critically appraise the methodology of developing modified obstetric early warning scores (MOEWSs). STUDY DESIGN AND SETTING: We searched Medline, CINAHL, EMBASE, and the Web of Science for MOEWS studies published between January 1, 2000, and December 31, 2022. Eligible studies included models predicting maternal death, intensive care unit (ICU) admission, and/or a composite of two or more maternal morbidities occurring in a hospital setting in women of any gestational age and up to 1 week after the end of pregnancy. Models were critically appraised using the Prediction Model Risk of Bias Assessment Tool (PROBAST) and adherence to the transparent reporting of prediction models (TRIPOD). RESULTS: 20 studies were included: five (25%) were model development studies, five (25%) were model development and validation, and ten (50%) were validation only. Four development studies used statistical methods, and the remaining six studies used clinical consensus (ie, expert opinion). The four data-driven model development studies did not address key statistical challenges, such as repeated measures or missing data, nor did they assess the performance adequately or dataset characteristics clearly. All but one study (95%) were rated at high risk of bias due to data sources, poor reporting, and analysis limitations. The fifteen validation studies were poorly reported and eleven (73%) were at high risk of bias. None of the data-driven models were independently validated, a key step toward implementation. CONCLUSION: There is a lack of MOEWSs developed using methods that follow recommended statistical guidelines. Substantial problems with the methodological quality of included development and validation studies, along with high risk of bias,indicating published scores could perform poorly or be potentially harmful if used in clinical practice. Future work should address handling missing data and repeated measures and consider how an MOEWS will perform in different populations and key subgroups.

来源:J Clin Epidemiol,查看原文。版权归原作者所有。

引用

  1. Chester-Jones M, Kirtley S, Er F, et al. Maternal early warning scores shown to be methodologically weak and at high risk of bias. J Clin Epidemiol. 2025. PMID: 40398687. doi:10.1016/j.jclinepi.2025.111833

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。