文献速递流行病学与生物统计真实世界研究与卫生经济

轴承面材料与初次全髋关节置换术后翻修风险的关联:基于国家关节登记系统1,026,481例髋关节置换的队列分析

The association of bearing surface materials with the risk of revision following primary total hip replacement: A cohort analysis of 1,026,481 hip replacements from the National Joint Registry.
PubMed 文献 · PLoS Med · 2024-11-07

该队列分析纳入2003至2019年英格兰和威尔士国家关节登记系统中1,026,481例初次全髋关节置换,分析不同轴承面材料的翻修风险。结果显示,与钴铬头配高交联聚乙烯(HCLPE)杯/内衬相比,delta陶瓷头或氧化锆头配HCLPE杯/内衬的翻修风险更低;而钴铬或不锈钢头配非HCLPE杯的翻修风险更高。

要点

  • Monobloc假体中,钴铬头配非HCLPE杯10年翻修风险高于钴铬头配HCLPE杯(HR 1.28)。
  • Modular假体中,delta陶瓷头(HR 0.79)或氧化锆头(HR 0.65)配HCLPE内衬的翻修风险低于钴铬头配HCLPE内衬。
  • 作者结论认为delta陶瓷或氧化锆头配HCLPE内衬/杯的假体翻修风险最低。

核心结论

  • 假体翻修受初次手术所用假体材料影响,delta陶瓷或氧化锆头配HCLPE内衬/杯的假体翻修风险最低。
  • 需进一步研究以确定植入物轴承材料与再住院、非翻修再手术、死亡率及这些材料成本效益的关联。

研究设计与样本

  • 分析2003至2019年英格兰和威尔士所有骨科单位的初次全髋关节置换术,纳入公立和私营部门接受初次全髋关节置换的患者。
  • 使用灵活参数生存分析估计调整后的风险比(HR),研究全因和特定适应证的翻修风险。
  • 共分析1,026,481例初次全髋关节置换(Monobloc:n=378,979;Modular:n=647,502),其中20,869例(2%)后续发生翻修(Monobloc:n=7,381;Modular:n=13,488)。

主要发现

  • Monobloc假体中,与钴铬头配HCLPE杯相比,钴铬头配非HCLPE杯的全因翻修风险更高(术后10年风险率:1.28,95%CI 1.10-1.48),不锈钢头配非HCLPE杯也更高(1.18,95%CI 1.02-1.36)。
  • Monobloc假体中,delta陶瓷头配HCLPE杯的翻修风险在任何术后时期均更低(1.18,95%CI 1.02-1.36)。
  • Modular假体中,与钴铬头配HCLPE内衬相比,全因翻修风险非恒定变化;delta陶瓷头(0.79,95%CI 0.73-0.85)或氧化锆头(0.65,95%CI 0.55-0.77)配HCLPE内衬在整个术后时期翻修风险更低。
  • Monobloc和Modular假体的特定适应证翻修风险分析结果与全因分析相似。

关键数值与推荐

  • Monobloc假体:与钴铬头配HCLPE杯相比,钴铬头配非HCLPE杯的10年翻修风险率HR 1.28(95%CI 1.10-1.48),不锈钢头配非HCLPE杯HR 1.18(95%CI 1.02-1.36),delta陶瓷头配HCLPE杯HR 1.18(95%CI 1.02-1.36)。
  • Modular假体:与钴铬头配HCLPE内衬相比,delta陶瓷头配HCLPE内衬HR 0.79(95%CI 0.73-0.85),氧化锆头配HCLPE内衬HR 0.65(95%CI 0.55-0.77)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 尽管该大型非选择性分析首次调整了登记系统中收集的众多特征,但不能排除残余混杂。
  • 需进一步研究以确定植入物轴承材料与再住院、非翻修再手术、死亡率及这些材料成本效益的关联。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The risk of re-operation, otherwise known as revision, following primary hip replacement depends in part on the prosthesis implant materials used. Current performance evidences are based on a broad categorisation grouping together different materials with potentially varying revision risks. We investigated the revision rate of primary total hip replacement (THR) reported in the National Joint Registry by specific types of bearing surfaces used. METHODS AND FINDINGS: We analysed THR procedures across all orthopaedic units in England and Wales. All patients who received a primary THR between 2003 and 2019 in the public and private sectors were included. We investigated the all-cause and indication-specific risks of revision using flexible parametric survival analyses to estimate adjusted hazard ratios (HRs). We identified primary THRs with heads and monobloc cups or modular acetabular component THRs with head and shell/liner combinations. A total of 1,026,481 primary THRs were analysed (Monobloc: n = 378,979 and Modular: n = 647,502) with 20,869 (2%) of these primary THRs subsequently undergoing a revision episode (Monobloc: n = 7,381 and Modular: n = 13,488). For monobloc implants, compared to implants with a cobalt chrome head and highly crosslinked polyethylene (HCLPE) cup, the all-cause risk of revision for monobloc acetabular implant was higher for patients with cobalt chrome (hazard rate at 10 years after surgery: 1.28 95% confidence intervals [1.10, 1.48]) or stainless steel head (1.18 [1.02, 1.36]) and non-HCLPE cup. The risk of revision was lower for patients with a delta ceramic head and HCLPE cup implant, at any postoperative period (1.18 [1.02, 1.36]). For modular implants, compared to patients with a cobalt chrome head and HCLPE liner primary THR, the all-cause risk of revision for modular acetabular implant varied non-constantly. THRs with a delta ceramic (0.79 [0.73, 0.85]) or oxidised zirconium (0.65 [0.55, 0.77]) head and HCLPE liner had a lower risk of revision throughout the entire postoperative period. Similar results were found when investigating the indication-specific risks of revision for both the monobloc and modular acetabular implants. While this large, nonselective analysis is the first to adjust for numerous characteristics collected in the registry, residual confounding cannot be rule out. CONCLUSIONS: Prosthesis revision is influenced by the prosthesis materials used in the primary procedure with the lowest risk for implants with delta ceramic or oxidised zirconium head and an HCLPE liner/cup. Further work is required to determine the association of implant bearing materials with the risk of rehospitalisation, re-operation other than revision, mortality, and the cost-effectiveness of these materials.

来源:PLoS Med,查看原文。版权归原作者所有。

引用

  1. Whitehouse MR, Patel R, French JMR, et al. The association of bearing surface materials with the risk of revision following primary total hip replacement: A cohort analysis of 1,026,481 hip replacements from the National Joint Registry. PLoS Med. 2024. PMID: 39509352. doi:10.1371/journal.pmed.1004478

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。