文献速递医学人工智能与信息学临床试验与 GCP流行病学与生物统计

人工智能心电图警报干预与全因死亡率:一项实用性随机临床试验

AI-enabled electrocardiography alert intervention and all-cause mortality: a pragmatic randomized clinical trial.
PubMed 文献 · Nat Med · 2024-04-29

该多中心随机对照试验纳入39名医生和15965例住院患者,评估人工智能心电图警报(含AI报告与警告信息)对死亡率的影响。干预组90天全因死亡率为3.6%,对照组为4.3%(HR=0.83,95%CI 0.70-0.99)。预设分析显示死亡率降低主要见于高危心电图患者(HR=0.69,95%CI 0.53-0.90)。

要点

  • AI心电图警报使90天全因死亡率从对照组4.3%降至干预组3.6%(HR=0.83,95%CI 0.70-0.99)。
  • 高危心电图患者中,AI警报与全因死亡率降低相关(HR=0.69,95%CI 0.53-0.90)。
  • 高危心电图患者中,干预组心脏死亡风险为0.2%,对照组为2.4%(HR=0.07,95%CI 0.01-0.56)。

核心结论

  • 实施AI心电图警报与90天全因死亡率显著降低相关,主要见于高危心电图患者。
  • AI心电图警报有助于识别高危患者、促使及时临床照护并降低死亡率,但具体机制尚待完全阐明。

研究设计与样本

  • 多中心实用性随机对照试验,纳入39名医生和15965例住院患者。
  • 干预为向医生发送AI心电图报告和警告信息,标记预测死亡高风险的患者。

主要发现

  • 干预组90天全因死亡率为3.6%,对照组为4.3%(HR=0.83,95%CI 0.70-0.99)。
  • 预设分析显示,高危心电图患者中AI警报与全因死亡率降低相关(HR=0.69,95%CI 0.53-0.90)。
  • 高危心电图患者中,干预组心脏死亡率为0.2%,对照组为2.4%(HR=0.07,95%CI 0.01-0.56)。
  • 次要结局分析显示,高危心电图患者中干预组接受的重症监护水平高于对照组。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • AI心电图警报导致死亡率降低的具体机制尚待完全阐明。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The early identification of vulnerable patients has the potential to improve outcomes but poses a substantial challenge in clinical practice. This study evaluated the ability of an artificial intelligence (AI)-enabled electrocardiogram (ECG) to identify hospitalized patients with a high risk of mortality in a multisite randomized controlled trial involving 39 physicians and 15,965 patients. The AI-ECG alert intervention included an AI report and warning messages delivered to the physicians, flagging patients predicted to be at high risk of mortality. The trial met its primary outcome, finding that implementation of the AI-ECG alert was associated with a significant reduction in all-cause mortality within 90 days: 3.6% patients in the intervention group died within 90 days, compared to 4.3% in the control group (4.3%) (hazard ratio (HR) = 0.83, 95% confidence interval (CI) = 0.70-0.99). A prespecified analysis showed that reduction in all-cause mortality associated with the AI-ECG alert was observed primarily in patients with high-risk ECGs (HR = 0.69, 95% CI = 0.53-0.90). In analyses of secondary outcomes, patients in the intervention group with high-risk ECGs received increased levels of intensive care compared to the control group; for the high-risk ECG group of patients, implementation of the AI-ECG alert was associated with a significant reduction in the risk of cardiac death (0.2% in the intervention arm versus 2.4% in the control arm, HR = 0.07, 95% CI = 0.01-0.56). While the precise means by which implementation of the AI-ECG alert led to decreased mortality are to be fully elucidated, these results indicate that such implementation assists in the detection of high-risk patients, prompting timely clinical care and reducing mortality. ClinicalTrials.gov registration: NCT05118035 .

来源:Nat Med,查看原文。版权归原作者所有。

引用

  1. Lin CS, Liu WT, Tsai DJ, et al. AI-enabled electrocardiography alert intervention and all-cause mortality: a pragmatic randomized clinical trial. Nat Med. 2024. PMID: 38684860. doi:10.1038/s41591-024-02961-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。