文献速递临床试验与 GCP医学人工智能与信息学基础与转化研究

基于人工智能的导航系统辅助牵引成骨治疗3至18岁半侧颜面短小畸形的疗效:随机对照单盲试验研究方案

Efficacy of navigation system-assisted distraction osteogenesis for hemifacial microsomia based on artificial intelligence for 3 to 18 years old: study protocol for a randomized controlled single-blind trial.
PubMed 文献 · Trials · 2024-01-12

本研究为单中心随机对照试验,计划纳入22例半侧颜面短小畸形患者,随机分为实验组和对照组,实验组采用基于人工智能的电磁导航系统辅助下颌骨牵引成骨术,对照组行传统手术,主要结局为通过Geomagic Control软件比较术前与术后CT图像评估的截骨位置手术精度。

要点

  • 单中心随机对照试验,计划纳入22例3至18岁半侧颜面短小畸形患者。
  • 实验组采用基于人工智能的电磁导航系统辅助下颌骨牵引成骨术,对照组行传统手术。
  • 主要结局为通过Geomagic Control软件比较术前与术后CT图像评估的截骨位置手术精度。

核心结论

  • 本试验旨在明确基于人工智能的电磁导航系统在提高半侧颜面短小畸形患者下颌骨牵引成骨术精度方面的效果。

研究设计与样本

  • 单中心随机对照试验,共22例半侧颜面短小畸形患者随机分配至实验组和对照组。
  • 所有患者接受三维CT扫描和术前手术计划,实验组设置电磁导航系统,对照组行传统手术。

主要发现

  • 主要结局为通过Geomagic Control软件比较术前与术后CT扫描图像的截骨位置评估手术精度。
  • 次要结局包括下颌对称性(咬合平面偏斜角、下颌支高度和体长)、疼痛评分和并发症。
  • 其他指标如系统不良事件和患者及其家属的满意度评分将被记录。

局限性

  • 本试验为小样本随机对照试验。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Mandibular distraction osteogenesis (MDO) is a major part of the treatment for hemifacial microsomia patients. Due to the narrow surgical field of the intraoral approach, osteotomy accuracy is highly dependent on the surgeons' experience. Electromagnetic (EM) tracking systems can achieve satisfying accuracy to provide helpful real-time surgical navigation. Our research team developed an EM navigation system based on artificial intelligence, which has been justified in improving the accuracy of osteotomy in the MDO in animal experiments. This study aims to clarify the effect of the EM navigation system in improving the MDO accuracy for hemifacial microsomia patients. METHODS: This study is designed as a single-centered and randomized controlled trial. Altogether, 22 hemifacial microsomia patients are randomly assigned to the experiment and control groups. All patients receive three-dimensional CT scans and preoperative surgical plans. The EM navigation system will be set up for those in the experiment group, and the control group will undergo traditional surgery. The primary outcome is the surgical precision by comparing the osteotomy position of pre- and postoperative CT scan images through the Geomagic Control software. The secondary outcomes include mandibular symmetry (occlusal plane deviation angle, mandibular ramus height, and body length), pain scale, and complications. Other indications, such as the adverse events of the system and the satisfactory score from patients and their families, will be recorded. DISCUSSION: This small sample randomized controlled trial intends to explore the application of an EM navigation system in MDO for patients, which has been adopted in other surgeries such as orthognathic procedures. Because of the delicate structures of children and the narrow surgical view, accurate osteotomy and protection of nearby tissue from injury are essential for successful treatment. The EM navigation system based on artificial intelligence adopted in this trial is hypothesized to provide precise real-time navigation for surgeons and optimally improve patient outcomes, including function and aesthetic results. The results of this trial will extend the application of new navigation technology in pediatric plastic surgery. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR2200061565. Registered on 29 June 2022.

来源:Trials,查看原文。版权归原作者所有。

引用

  1. Liu X, Zhang Z, Han W, et al. Efficacy of navigation system-assisted distraction osteogenesis for hemifacial microsomia based on artificial intelligence for 3 to 18 years old: study protocol for a randomized controlled single-blind trial. Trials. 2024. PMID: 38216974. doi:10.1186/s13063-023-07809-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。