文献速递临床试验与 GCP

反式肩关节外侧化盂球延长线系统的植入物迁移与功能结局:一项随机对照试验的研究方案

Implant migration and functional outcome of Reverse Shoulder Lateralized Glenosphere Line Extension System: a study protocol for a randomized controlled trial.
PubMed 文献 · Trials · 2022-07-19

本研究为随机对照试验方案,拟纳入122例因肩袖关节病或肩盂肱关节退变伴严重后方磨损而计划接受反式全肩关节置换的丹麦患者,比较DELTA Xtend®外侧化盂球延长线系统(干预组)与标准DELTA Xtend®系统(对照组)的放射学与功能结局。主要结局为放射立体测量分析评估的盂假体迁移模式与幅度及Western Ontario肩关节骨关节炎指数,共56例参与放射立体测量分析。

要点

  • 方案拟纳入122例反式全肩关节置换患者,其中56例参与放射立体测量分析。
  • 干预组为DELTA Xtend®外侧化盂球延长线系统,对照组为标准DELTA Xtend®系统。
  • 主要结局为盂假体迁移的放射立体测量分析及Western Ontario肩关节骨关节炎指数。

核心结论

  • 作者假设外侧化通过降低肩胛骨下切迹风险而不增加盂假体迁移和松动风险来改善患者结局。
  • 研究拟确定哪种治疗对将来有反式肩关节置换指征的患者具有最优结局。

研究设计与样本

  • 随机对照试验,在哥本哈根大学医院Herlev和Gentofte医院骨科择期反式全肩关节置换的丹麦公民中筛选参与者。
  • 计划纳入122例患者,其中56例参与放射立体测量分析,该样本量允许20%脱落。
  • 排除标准为年龄低于50岁、认知或语言障碍、盂骨量不足、上肢既往骨折及自身免疫介导的炎性关节炎。
  • 随访检查时间为术前、术后1周内及术后3、6、12和24个月。

主要发现

  • 共同主要结局为放射立体测量分析评估的盂假体迁移模式和幅度,以及Western Ontario肩关节骨关节炎指数。
  • 次要结局包括肩胛骨下切迹、患者报告和功能结局(Oxford肩关节评分、Constant-Murley评分和疼痛)、副作用和并发症、骨密度变化及经济学指标。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Inferior scapular notching is a complication unique to reverse shoulder arthroplasty. The most efficient technique to avoid inferior scapular notching has been reported to be lateralization of the glenoid offset. This study aims to compare radiological and functional outcomes of the DELTA Xtend® Reverse Shoulder System Lateralized Glenosphere Line Extension (intervention group) with the Standard DELTA Xtend® Reverse Shoulder System (control group). We hypothesize that the lateralization improves the patient outcome by decreasing the risk of inferior scapular notching without increasing the risk of migration and loosening of glenoid component. METHODS: In this randomized controlled trial, all Danish citizens with rotator cuff arthropathy or degeneration of the glenohumeral joint with severe posterior wear and allocated for a reverse total shoulder arthroplasty at the department of orthopaedic surgery at Herlev and Gentofte Hospital, Copenhagen University Hospital, will be considered for participation. The exclusion criteria are as follows: below 50 years of age, cognitive or linguistic impairment, insufficient glenoid bone stock, previous fracture in the upper extremity and autoimmune-mediated inflammatory arthritis. There will be included a total of 122 patients of which 56 will participate in the radiostereometric analysis. This number of patients allows 20% to drop out. The co-primary outcomes are the pattern and magnitude of the migration of the glenoid component assessed by radiostereometric analysis and the Western Ontario Osteoarthritis of the Shoulder index. The secondary outcomes are inferior scapular notching, patient-reported and functional outcomes (Oxford shoulder score, Constant-Murley score and pain), side effects and complications, changes in bone mineral density and economy. The included patients will be examined before the surgery, within 1 week and 3, 6, 12 and 24 months after. DISCUSSION: No previous studies have compared the conventional reverse shoulder arthroplasty with the lateralized reverse shoulder arthroplasty in a randomized controlled trial regarding migration and functional outcome. Furthermore, radiostereometric analysis has not been used to evaluate the migration of reverse shoulder arthroplasty in a randomized controlled trial. This study intends to determine which treatment has the most optimal outcome for the benefit of future patients with an indication for reverse shoulder arthroplasty. TRIAL REGISTRATION: The study has been notified to Pactius and has approval number P-2021-231. Furthermore, the study will be registered on Clinicaltrials.gov before starting the inclusion.

来源:Trials,查看原文。版权归原作者所有。

引用

  1. Jensen ML, Olsen BS, Nyring MRK, et al. Implant migration and functional outcome of Reverse Shoulder Lateralized Glenosphere Line Extension System: a study protocol for a randomized controlled trial. Trials. 2022. PMID: 35854390. doi:10.1186/s13063-022-06482-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。