止血带应用对全膝关节置换术患者股四头肌形态与功能的影响:单盲随机对照试验研究方案
本研究为前瞻性、单盲、随机对照试验,计划纳入130例符合标准的全膝关节置换术患者,随机分为止血带组与非止血带组,主要结局为超声评估的股四头肌厚度,次要结局包括股四头肌硬度、康复结局、手术时间、围手术期失血量、输血率、大腿周径、VAS评分、阿片类药物消耗量、血清D-二聚体和C反应蛋白水平、膝关节功能评分、术后满意度评分及并发症,旨在为止血带临床应用提供证据。
要点
- 止血带在全膝关节置换术中应用存在学术争议,股四头肌损伤被认为是主要副作用。
- 该试验计划纳入130例患者,随机分为止血带组与非止血带组,采用单盲设计。
- 主要结局为超声测量的股四头肌厚度,重点评估止血带对股四头肌形态与功能的影响。
核心结论
- 本研究旨在探讨止血带应用对全膝关节置换术患者股四头肌形态与功能的影响,并为临床实践中止血带的应用提供建议。
研究设计与样本
- 前瞻性、单盲、随机对照试验,目标样本量为130例,符合纳入标准的患者随机分配至止血带组和非止血带组。
主要发现
- 原文未报告研究结果。
关键数值与推荐
- 主要结局为超声评估的股四头肌厚度;次要结局包括股四头肌硬度、康复结局、手术时间、术中及术后失血量、输血率、大腿周径、VAS评分、阿片类药物消耗量、血清D-二聚体和C反应蛋白水平、膝关节功能评分、术后满意度评分及并发症。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Tourniquet is currently widely used in total knee arthroplasty to reduce intraoperative blood loss. The academic view of tourniquet application in TKA is now in dispute. Some scholars argue that tourniquet may cause quadriceps injury and bring extra side effects, so they oppose the application of tourniquet. Others find that tourniquet application has no significant adverse impact on TKA patients. Regarding its advantages in reducing intraoperative blood loss, they advocate the regular application of tourniquet in TKA. Quadriceps injury is considered the main cause of tourniquet side effects. There are now many high-quality trials about tourniquet application in TKA but few of them concentrate on quadriceps morphology and function. METHODS: A prospective, single-blind, randomized controlled trial will be adopted. The target sample is 130. Patients who meet the eligibility criteria will be randomly allocated to the tourniquet group and non-tourniquet group. The primary outcome is quadriceps thickness evaluated by ultrasound test. Secondary outcomes include quadriceps stiffness, rehabilitation outcomes, operation time, intraoperative and postoperative blood loss, blood transfusion rate, thigh circumference, VAS score, opioid consumption, D-dimer and C-reactive protein level in the serum, knee function score, postoperative satisfaction score, and complications. DISCUSSION: This proposed study will contribute to improve evidence of tourniquet application in total knee arthroplasty. This will be a high-quality single-blind randomized controlled trial with a sufficient sample size and strict study design. It will investigate the effects of tourniquet application especially on the morphology and function of quadriceps in patients undergoing total knee arthroplasty and offer advice for tourniquet application in clinical practice. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR2000035097 . Registered on 31 July 2020.
引用
- Dong Z, Li Y, Tao L, et al. The effect of tourniquet application on the morphology and function of quadriceps in patients undergoing total knee arthroplasty: study protocol for a single-blind randomized controlled trial. Trials. 2022. PMID: 35248121. doi:10.1186/s13063-022-06114-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。