文献速递脊髓损伤康复

脊髓损伤独立性量表第四版在多文化环境中的信度、效度与反应度

Reliability Validity and Responsiveness of the Spinal Cord Independence Measure 4th Version in a Multicultural Setup.
PubMed 文献 · Arch Phys Med Rehabil · 2021-10-20

该研究在11个国家19个脊髓损伤中心的648例患者中,评估脊髓损伤独立性量表第四版(SCIM IV)的信度、效度与反应度,并与第三版(SCIM III)比较。结果显示SCIM IV评定者间信度、内部一致性、与SCIM III的相关性及反应度均良好,与SCIM III高度相似,可用于临床及国际多中心研究。

要点

  • SCIM IV评定者间信度良好,多数任务总一致率超过80%,Kappa系数均大于0.70。
  • SCIM IV与SCIM III高度相关(Pearson相关系数0.91-0.96),反应度多数比较无显著差异。
  • SCIM IV可用于临床和研究试验,包括国际多中心研究,组间评分可与SCIM III比较。

核心结论

  • SCIM IV的信度、效度和反应度均很好,与SCIM III相当。
  • SCIM IV可用于临床和研究试验,包括国际多中心研究,其组间评分可与SCIM III比较。

研究设计与样本

  • 部分盲法比较研究,以SCIM III为参照标准,并比较评定者间和评定次数间的一致性。
  • 纳入11个国家19个脊髓损伤单位的648例脊髓损伤患者,在入院康复时和出院前进行评估。

主要发现

  • 评定者间总一致率在多数SCIM IV任务上超过80%,所有Kappa系数均大于0.70且P<.001。
  • 评定者间Pearson相关系数大于0.90,组内相关系数大于0.90。
  • SCIM IV全量表Cronbach's alpha大于0.96,各分量表大于0.66,删除条目后alpha通常降低。
  • 呼吸和括约肌管理分量表以及入院时的信度值较低。
  • SCIM IV与SCIM III均值非常接近,Pearson相关系数为0.91-0.96(P<.001),多数比较中反应度无显著差异。

关键数值与推荐

  • 评定者间总一致率多数任务超过80%,Kappa系数均大于0.70(P<.001)。
  • 评定者间Pearson相关系数大于0.90,组内相关系数大于0.90。
  • 全量表Cronbach's alpha大于0.96,各分量表大于0.66。
  • SCIM IV与SCIM III的Pearson相关系数为0.91-0.96(P<.001)。

临床怎么用

  • SCIM IV可用于脊髓损伤患者的临床评估和临床研究。
  • SCIM IV适用于国际多中心研究,其组间评分可与SCIM III比较。
  • 使用SCIM IV时需注意呼吸和括约肌管理分量表及入院时信度相对较低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To examine the fourth version of the Spinal Cord Independence Measure for reliability and validity. DESIGN: Partly blinded comparison with the criterion standard Spinal Cord Independence Measure III, and between examiners and examinations. SETTING: A multicultural cohort from 19 spinal cord injury units in 11 countries. PARTICIPANTS: A total of 648 patients with spinal cord injury. INTERVENTION: Assessment with Spinal Cord Independence Measure (SCIM IV) and Spinal Cord Independence Measure (SCIM III) on admission to inpatient rehabilitation and before discharge. MAIN OUTCOME MEASURES: SCIM IV interrater reliability, internal consistency, correlation with and difference from SCIM III, and responsiveness. RESULTS: Total agreement between examiners was above 80% on most SCIM IV tasks. All Kappa coefficients were above 0.70 and statistically significant (P<.001). Pearson's coefficients of the correlation between the examiners were above 0.90, and intraclass correlation coefficients were above 0.90. Cronbach's alpha was above 0.96 for the entire SCIM IV, above 0.66 for the subscales, and usually decreased when an item was eliminated. Reliability values were lower for the subscale of respiration and sphincter management, and on admission than at discharge. SCIM IV and SCIM III mean values were very close, and the coefficients of Pearson correlation between them were 0.91-0.96 (P<.001). The responsiveness of SCIM IV was not significantly different from that of SCIM III in most of the comparisons. CONCLUSIONS: The validity, reliability, and responsiveness of SCIM IV, which was adjusted to assess specific patient conditions or situations that SCIM III does not address, and which includes more accurate definitions of certain scoring criteria, are very good and quite similar to those of SCIM III. SCIM IV can be used for clinical and research trials, including international multi-center studies, and its group scores can be compared with those of SCIM III.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. Catz A, Itzkovich M, Elkayam K, et al. Reliability Validity and Responsiveness of the Spinal Cord Independence Measure 4th Version in a Multicultural Setup. Arch Phys Med Rehabil. 2021. PMID: 34687675. doi:10.1016/j.apmr.2021.07.811

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。