多关节手臂外骨骼对卒中后上肢运动学评估的临床验证
结果显示UE-FMA可被多元回归模型显著预测(F(5,13)=12.22,p<0.0005,校正R²=0.83),肩内外旋和握力压力均显著贡献于预测。结论认为基于外骨骼的单关节运动评估对重度卒中患者上肢活动范围是临床可行的。
要点
- 外骨骼传感器评估与UE-FMA显著相关,多元回归模型校正R²=0.83。
- 肩内外旋(标准化β=0.55)和握力压力(β=0.38)显著贡献于临床状态预测。
- 腕与肘屈伸运动学参数间呈强相关(r>0.7,p<0.003,Bonferroni校正)。
核心结论
- 基于外骨骼的单关节运动自包含评估可对重度卒中患者上肢活动范围进行临床有效评估。
- 肩内外旋对临床状态预测贡献最相关。
研究设计与样本
- 分别评估腕、肘和肩屈伸(FE)及肩内外旋(IER)四个单关节的关节空间活动范围,以及手柄压力传感器检测的手部闭合与打开。
主要发现
- 腕与肘屈伸运动学参数间呈强相关(r>0.7,p<0.003,Bonferroni校正)。
- UE-FMA被多元回归模型显著预测(F(5,13)=12.22,p<0.0005,校正R²=0.83)。
- 肩IER和握力压力均显著增加预测(p<0.05),标准化系数β分别为0.55和0.38。
关键数值与推荐
- UE-FMA预测模型:F(5,13)=12.22,p<0.0005,校正R²=0.83。
- 肩IER标准化β=0.55(p<0.05),握力压力标准化β=0.38(p<0.05)。
- 腕与肘FE相关r>0.7,p<0.003(Bonferroni校正)。
临床怎么用
- 对重度卒中患者上肢活动范围可采用外骨骼传感器评估作为客观补充。
- 评估时应关注肩内外旋和握力压力参数,因其对临床状态预测贡献显著。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The clinical evaluation of the upper limb of severely impaired stroke patient is challenging. Sensor-based assessments may allow for an objective evaluation of this patient population. This study investigated the validity of a device-assisted approach in comparison to the clinical outcome that it is supposed to reflect. METHODS: In nineteen severely impaired chronic stroke patients, we applied a gravity-compensating, multi-joint arm exoskeleton (Armeo Spring) and compared this sensor-based assessment with the clinical outcome measure Upper Extremity Fugl-Meyer Assessment (UE-FMA) scale. Specifically, we assessed separately and subsequently the range of motion in joint space for four single joints (i.e., wrist, elbow and shoulder flexion/extension (FE), and shoulder internal/external rotation (IER)), and the closing and opening of the hand with a pressure sensor placed in the handle. RESULTS: Within the kinematic parameters, a strong correlation was observed between wrist and elbow FE (r > 0.7, p < 0.003; Bonferroni corrected). The UE-FMA was significantly predicted by a multiple regression model (F (5, 13) = 12.22, p < 0.0005, adj. R2 = 0.83). Both shoulder IER and grip pressure added significantly (p < 0.05) to the prediction with the standardized coefficients β of 0.55 and 0.38, respectively. CONCLUSIONS: By applying an exoskeleton-based self-contained evaluation of single-joint movements, a clinically valid assessment of the upper limb range of motion in severely impaired stroke patients is feasible. Shoulder IER contributed most relevantly to the prediction of the clinical status. These findings need to be confirmed in a large, independent patient cohort.
引用
- Grimm F, Kraugmann J, Naros G, et al. Clinical validation of kinematic assessments of post-stroke upper limb movements with a multi-joint arm exoskeleton. J Neuroeng Rehabil. 2021. PMID: 34078400. doi:10.1186/s12984-021-00875-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。