文献速递神经康复

Kickstart步行辅助系统改善卒中幸存者平衡与步行功能的可行性研究

The Kickstart Walk Assist System for improving balance and walking function in stroke survivors: a feasibility study.
PubMed 文献 · J Neuroeng Rehabil · 2021-02-24

结果显示佩戴时负重不对称性降低、10米步行时间缩短、步时和双支撑时间减少,但计时起立-行走测试无差异;受试者对设备改善平衡、速度和步态持积极态度,信心和使用意愿也较好。

要点

  • 佩戴Kickstart无动力外骨骼可降低卒中幸存者负重不对称性并缩短10米步行时间。
  • 步态分析显示佩戴时步时和双支撑时间减少,但计时起立-行走测试无差异。
  • 受试者对设备改善平衡、速度和步态持积极态度,使用信心和意愿较好。

核心结论

  • Kickstart步行辅助系统用于改善卒中幸存者步行功能具有可行性。

主要发现

  • 与不佩戴设备相比,佩戴Kickstart时负重不对称性降低。
  • 佩戴Kickstart时10米步行测试时间缩短,但计时起立-行走测试无差异。
  • 步态分析数据显示佩戴时步时和双支撑时间减少。
  • 卒中幸存者对Kickstart改善平衡、速度和步态的能力评价积极,信心水平和使用意愿也积极。

关键数值与推荐

  • 研究评估了佩戴与不佩戴Kickstart两种状态下的时空步态指标、平衡指标和外骨骼使用反馈问卷。

临床怎么用

  • 卒中幸存者可尝试使用Kickstart无动力外骨骼进行步行训练,以改善负重对称性和步行速度。
  • 临床决策时需注意该设备对计时起立-行走测试未见改善,平衡与转移能力需结合其他评估。

局限性

  • 作者计划未来开展更长持续时间、更全面前后测试及更大样本的研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Compared with traditional physical therapy for stroke patients, lower extremity exoskeletons can provide patients with greater endurance and more repeatable and controllable training, which can reduce the therapeutic burden of the therapist. However, most exoskeletons are expensive, heavy or require active power to be operated. Therefore, a lighter, easy to wear, easy to operate, low-cost technology for stroke rehabilitation would be a welcome opportunity for stroke survivors, caregivers and clinicians. One such device is the Kickstart Walk Assist system and the purpose of this study was to determine feasibility of using this unpowered exoskeleton device in a sample of stroke survivors. METHODS: Thirty stroke survivors were enrolled in the study and experienced walking with the Kickstart exoskeleton device that provided spring-loaded assistance during gait. After 5 days of wearing the exoskeleton, participants were evaluated in the two states of wearing and not wearing the exoskeleton. Outcome measures included: (a) spatio-temporal gait measures, (b) balance measures and (c) exoskeleton-use feedback questionnaire. RESULTS: In comparison to not wearing the device, when participants wore the Kickstart walking system, weight bearing asymmetry was reduced. The time spent on the 10-m walk test was also reduced, but there was no difference in the timed-up-and-go test (TUGT). Gait analysis data showed reduction in step time and double support time. Stroke survivors were positive about the Kickstart walking system's ability to improve their balance, speed and gait. In addition, their confidence level and willingness to use the device was also positive. CONCLUSIONS: These findings show the feasibility of using the Kickstart walking system for improving walking performance in stroke survivors. Our future goal is to perform a longer duration study with more comprehensive pre- and post-testing in a larger sample of stroke survivors. Trial registration Chinese Clinical Trial Registry, ChiCTR2000032665. Registered 5 May 2020-Retrospectively registered, http://www.chictr.org.cn/showproj.aspx?proj=53288.

来源:J Neuroeng Rehabil,查看原文。版权归原作者所有。

引用

  1. Yao J, Sado T, Wang W, et al. The Kickstart Walk Assist System for improving balance and walking function in stroke survivors: a feasibility study. J Neuroeng Rehabil. 2021. PMID: 33627142. doi:10.1186/s12984-020-00795-y