慢性阻塞性肺疾病运动能力阶梯试验的测量学特性:系统综述
多数阶梯试验的效度、信度与反应度证据等级为低至极低,六分钟踏步试验在结构效度(高)、效标效度与反应度(中等)方面证据最佳,是目前最合适的阶梯试验。
要点
- 阶梯试验测量学特性总体证据等级为低至极低,限制临床应用。
- 六分钟踏步试验结构效度证据等级高(r=0.56-0.71)。
- 六分钟踏步试验效标效度与反应度证据等级中等。
核心结论
- 慢性阻塞性肺疾病患者运动能力阶梯试验的测量学特性总体证据等级为低至极低,可能限制其临床应用。
- 六分钟踏步试验是目前最合适的阶梯试验。
研究设计与样本
- 由一名评价者提取数据,两名评价者独立使用COSMIN推荐评定证据等级。
主要发现
- 识别出Chester踏步试验、改良增量踏步试验、2、3、4、6分钟踏步试验、节拍踏步试验和六分钟踏步试验等。
- 多数阶梯试验测量学特性的证据等级为低至极低。
- 六分钟踏步试验结构效度证据等级高(r=0.56-0.71)。
- 六分钟踏步试验效标效度证据等级中等(r=0.36-0.69),反应度证据等级中等(r=0.26-0.34)。
关键数值与推荐
- 六分钟踏步试验结构效度r=0.56-0.71,证据等级高。
- 六分钟踏步试验效标效度r=0.36-0.69,证据等级中等。
- 六分钟踏步试验反应度r=0.26-0.34,证据等级中等。
临床怎么用
- 在慢性阻塞性肺疾病患者运动能力评估中,可优先考虑六分钟踏步试验。
- 使用其他阶梯试验时需谨慎,因其测量学特性证据等级多为低至极低。
局限性
- 多数阶梯试验的测量学特性证据等级为低至极低,限制结论强度。
- 仅一名评价者提取数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine the level of evidence of the measurement properties (validity, reliability, and responsiveness) and interpretability of the step tests available for assessing the exercise capacity in patients with chronic obstructive pulmonary disease. DATA SOURCES: The data sources Web of Science, MEDLINE, PubMed, PEDro, CENTRAL of Cochrane Library, and Scopus were searched up to June 26, 2020. REVIEW METHODS: Studies of any design that reported results for any measurement property of the step tests for assessing the exercise capacity in COPD patients were selected. One reviewer extracted the data, and two reviewers independently rated the level of evidence by using the Consensus-Based Standards for the Selection of Health Measurements Instruments recommendations. RESULTS: Thirty-one studies were included in the data synthesis. Chester Step Test, Modified Incremental Step Test, two-, three-, four-, and six-Minute Step Test, Paced Step Test, and six-Minute Stepper Test were identified. A step test protocol was also found. The level of evidence of their results for the measurement properties was mostly determined as "low" to "very low." The best level of evidence found was for the six-minute stepper test: "high" on construct validity (r = 0.56-0.71); and "moderate" on criterion validity (r = 0.36-0.69), and responsiveness (r = 0.26-0.34). CONCLUSION: The general level of evidence of the measurement properties of the step tests is "low" to "very low" for assessing exercise capacity in patients with chronic obstructive pulmonary disease, which can limit their application in clinical practice. The six-minute Stepper Test is currently the most appropriate step test available.
引用
- Vilarinho R, Caneiras C, Montes AM, et al. Measurement properties of step tests for exercise capacity in COPD: A systematic review. Clin Rehabil. 2020. PMID: 33155491. doi:10.1177/0269215520968054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。