文献速递脊髓损伤康复

改良坐位功能测试在慢性脊髓损伤中的心理测量与临床效用

Psychometric Testing and Clinical Utility of a Modified Version of the Function in Sitting Test for Individuals With Chronic Spinal Cord Injury.
PubMed 文献 · Arch Phys Med Rehabil · 2020-07-13

本研究由专家小组改良坐位功能测试(FIST-SCI),对38例慢性脊髓损伤患者(损伤平面C1-T10)在两天内由两名评估者进行测试,并与运动评估量表坐位项(MAS-SCI)比较。结果显示FIST-SCI与MAS-SCI呈中度相关(ρ=.522,P<.05),组内和组间信度优秀(ICC=.985和.983),内部一致性优秀(α=.94), cutoff值45分及以上区分转移能力的敏感度和特异度均为92%。

要点

  • FIST-SCI在慢性脊髓损伤患者中信度优秀,组内和组间ICC分别为.985和.983。
  • FIST-SCI得分45分及以上区分转移需要辅助与独立的敏感度和特异度均为92%。
  • FIST-SCI与MAS-SCI呈中度相关(ρ=.522,P<.05),初步效度得到支持。

核心结论

  • FIST-SCI在慢性脊髓损伤患者中信度优秀,初步效度得到支持,但需进一步评估。
  • FIST-SCI得分可提供慢性脊髓损伤患者坐位功能能力的临床洞察。

研究设计与样本

  • 由专家小组对FIST进行改良形成FIST-SCI,由2名评估者在2个独立日评估慢性脊髓损伤患者的坐位平衡。
  • 以运动评估量表第3项(MAS-SCI)作为比较测量。

主要发现

  • FIST-SCI与MAS-SCI呈中度相关(ρ=.522;P<.05)。
  • FIST-SCI得分可区分转移需要辅助与独立的个体(t=4.51;P<.05)。
  • 组内和组间信度优秀(ICC(2,k)=.985和.983),内部一致性优秀(α=.94)。
  • FIST-SCI cutoff值45分及以上区分转移能力的敏感度和特异度均为92%。
  • 测量标准误(1.3)和最小可检测变化(3.5)与既往研究相似。

关键数值与推荐

  • FIST-SCI cutoff值45分及以上区分转移能力的敏感度和特异度均为92%。
  • 组内和组间信度ICC(2,k)分别为.985和.983,内部一致性α=.94。
  • FIST-SCI与MAS-SCI的相关系数ρ=.522(P<.05)。
  • 测量标准误为1.3,最小可检测变化为3.5。

临床怎么用

  • FIST-SCI可用于评估慢性脊髓损伤患者的坐位平衡功能。
  • FIST-SCI得分45分及以上提示患者转移可能独立,敏感度和特异度均为92%。
  • FIST-SCI信度优秀,可用于临床监测坐位功能能力。

局限性

  • FIST-SCI的初步效度已报告,但需进一步评估。
  • 研究样本为慢性脊髓损伤患者,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Seated balance (SB) is substantially compromised and greatly impacts the function of individuals living with a spinal cord injury (SCI). A clinically applicable criterion standard measure for SB does not exist for this population. Initial validation and reliability analysis of the Function in Sitting Test (FIST) in SCI has been published, but the authors of this study report that modifications to the tool may be necessary. This study aimed to explore the psychometrics and clinical utility of a modified version of the FIST to better measure SCI-specific functional tasks in sitting. DESIGN: The FIST was modified (FIST-SCI) by an expert panel and used by 2 graders to evaluate the SB of individuals with chronic SCI (cSCI) on 2 separate days. The Motor Assessment Scale item 3 (MAS-SCI) was included as a comparison measure. SETTING: Research facility. PARTICIPANTS: Individuals with cSCI longer than 1 year (N=38) participated in the study. Injury levels of individuals participating in this study spanned C1 to T10 (American Spinal Injury Association Impairment Scale A, 17 subjects; B, 12 subjects; and C, 9 subjects). Thirteen individuals required assistance to transfer. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Validity, reliability, internal consistency, sensitivity, specificity, and responsiveness. RESULTS: Validity testing found a moderate relationship between the MAS-SCI and the FIST-SCI (ρ, .522; P<.05). FIST-SCI scores distinguished individuals requiring assistance to transfer from those who were independent (t=4.51; P<.05). Inter- and intra-rater reliability were excellent (intraclass correlation coefficient (2,k)=.985 and .983, respectively) and internal consistency was excellent (α=.94). A FIST-SCI cutoff score of 45 or greater was 92% sensitive and specific in characterizing transfer ability. Standard error of the measure (1.3) and minimal detectable change (3.5) were similar to previous work. CONCLUSIONS: Initial validity of the FIST-SCI is reported, but further assessment is required. Reliability is excellent in the cSCI population. FIST-SCI scores provide clinical insight into the seated functional ability of individuals with cSCI.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. Palermo AE, Cahalin LP, Garcia KL, et al. Psychometric Testing and Clinical Utility of a Modified Version of the Function in Sitting Test for Individuals With Chronic Spinal Cord Injury. Arch Phys Med Rehabil. 2020. PMID: 32673654. doi:10.1016/j.apmr.2020.06.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。