文献速递脊髓损伤康复神经康复

使用腕戴式ActiGraph监测仪估算脊髓损伤患者身体活动强度

Estimation of Physical Activity Intensity in Spinal Cord Injury Using a Wrist-Worn ActiGraph Monitor.
PubMed 文献 · Arch Phys Med Rehabil · 2020-06-02

本研究针对17名脊髓损伤手动轮椅使用者,通过便携代谢仪和腕戴ActiGraph监测仪完成18项日常生活活动,利用交叉验证推导久坐、轻强度和中等至剧烈活动(MVPA)的加速度阈值。结果显示久坐与轻强度阈值为2057 counts/min,轻强度与MVPA阈值为11551 counts/min,久坐行为识别准确度高,但MVPA阈值在抗阻活动较多时可能不准确。

要点

  • 久坐与轻强度活动阈值为2057 counts/min。
  • 轻强度与MVPA活动阈值为11551 counts/min。
  • 久坐行为识别灵敏度95.3%、特异度97.4%。

核心结论

  • 基于加速度计的阈值可准确识别脊髓损伤手动轮椅使用者的久坐行为,但可能无法准确估算全天MVPA,尤其在抗阻活动较多时。

研究设计与样本

  • 参与者完成18项日常生活活动和锻炼,每项10分钟,间隔3分钟休息,同时佩戴COSMED K4b2便携代谢仪和优势腕ActiGraph活动监测仪。

主要发现

  • 基于80%参与者数据线性回归获得阈值,并在剩余20%参与者中测试,交叉验证迭代1000次,最终在独立样本外数据集验证。
  • 久坐与轻强度阈值为2057 counts/min,轻强度与MVPA阈值为11551 counts/min。
  • 样本外验证总体准确率85.6%,久坐行为灵敏度95.3%、特异度97.4%,轻强度灵敏度87.8%、特异度84.5%,MVPA灵敏度68.5%、特异度96.3%。

关键数值与推荐

  • MET值≤1.5分类为久坐行为,MET值在1.5至3之间分类为轻强度,MET值≥3分类为MVPA。
  • 样本外验证数据集包含17名脊髓损伤手动轮椅使用者。

临床怎么用

  • 临床可使用腕戴ActiGraph监测仪和上述阈值识别脊髓损伤手动轮椅使用者的久坐行为。
  • 在评估全天MVPA时需注意,当参与者进行较多抗阻活动时阈值可能不准确。

局限性

  • 样本量较小(样本外验证N=17)。
  • 阈值可能无法准确估算抗阻活动较多时的MVPA。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To derive accelerometer count thresholds for classifying time spent in sedentary, light intensity, and moderate-to-vigorous physical activity (MVPA) in manual wheelchair users (MWUs) with spinal cord injury (SCI). DESIGN: Participants completed 18 activities of daily living and exercises for 10 minutes each with a 3-minute break between activities while wearing a COSMED K4b2 portable metabolic cart and an ActiGraph activity monitor on the dominant wrist. A linear regression was computed between the wrist acceleration vector magnitude and SCI metabolic equivalent of task (MET) for 80% of the participants to obtain thresholds for classifying different activity intensities, and the obtained thresholds were tested for accuracy on the remaining 20% of participants. This cross-validation process was iterated for 1000 times to evaluate the stability of the thresholds on data corresponding to different proportions of sedentary, light intensity, and MVPA. MET values of 1.5 or lower were classified as sedentary behavior, MET values between 1.5 and 3 were classified as light intensity, and MET values of 3 or higher were classified as MVPA. The final thresholds were then validated on an out-of-sample independent dataset. PARTICIPANTS: MWUs (N=17) with SCI in the out-of-sample validation data set. INTERVENTIONS: Not applicable. SETTING: Research lab, community MAIN OUTCOME MEASURES: Accelerometer thresholds to classify sedentary, light intensity, and MVPA were obtained and their accuracy tested using cross-validation and an out-of-sample dataset. RESULTS: The threshold between sedentary and light intensity was 2057 counts-per-minute, and the threshold between light intensity and MVPA was 11,551 counts per minute. Based on the out-of-sample validation, the obtained thresholds had an overall accuracy of 85.6%, with a sensitivity and specificity of 95.3% and 97.4% for sedentary behavior, 87.8% and 84.5% for light intensity, 68.5% and 96.3% for MVPA, respectively. CONCLUSION: Accelerometer-based thresholds can be used to accurately identify sedentary behavior. However, thresholds may not provide accurate estimations of MVPA throughout the day when participants engage in more resistance-based activities.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. Veerubhotla A, Hong E, Knezevic S, et al. Estimation of Physical Activity Intensity in Spinal Cord Injury Using a Wrist-Worn ActiGraph Monitor. Arch Phys Med Rehabil. 2020. PMID: 32502566. doi:10.1016/j.apmr.2020.05.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。