文献速递脊髓损伤康复神经康复

亚急性脊髓损伤后周围神经系统的电生理变化

Electrophysiological Changes in the Peripheral Nervous System After Subacute Spinal Cord Injury.
PubMed 文献 · Arch Phys Med Rehabil · 2020-02-05

本研究回顾性分析42例亚急性脊髓损伤患者,根据损伤平面以下肌电图有无失神经电位分组,比较两组临床特征与电生理结果。发现失神经电位组AIS A或B比例更高、下肢运动评分更低,且神经传导、体感诱发电位和运动诱发电位无反应比例更高,轴索丢失更明显。提示亚急性SCI患者损伤平面以下可发生周围神经功能障碍,可能与SCI严重程度相关。

要点

  • 亚急性SCI患者损伤平面以下可出现失神经电位等周围神经损害表现。
  • 失神经电位与更严重的SCI(AIS A/B)及更低的下肢运动评分相关。
  • 失神经电位组神经传导、SSEP和MEP无反应比例更高,轴索丢失更明显。

核心结论

  • 亚急性SCI患者损伤平面以下可发生周围神经功能障碍,可能与SCI严重程度相关。

研究设计与样本

  • 回顾性观察性研究,审查151例SCI患者病历,最终纳入42例无其他致周围神经异常疾病的受试者。
  • 受试者按损伤平面以下肌电图有无失神经电位分为两组。
  • 研究场所为大学医院住院康复中心。

主要发现

  • 损伤平面以下肌电图失神经电位见于20例,其中10例为AIS A或B,而无失神经电位组中无一例AIS A或B(P<.001)。
  • 失神经电位组下肢运动评分为4.35±7.74,低于无失神经电位组的33.64±13.60(P<.001)。
  • 失神经电位组无反应比例更高:腓总神经传导60.0% vs 11.4%,胫神经传导35.0% vs 2.3%,SSEP 80.0% vs 18.2%,MEP 87.5% vs 22.7%(P均<.001)。
  • 失神经电位组神经传导显示波幅降低而潜伏期未延迟,提示轴索丢失更明显(P<.001)。

临床怎么用

  • 对亚急性SCI患者,尤其AIS A/B或下肢运动评分较低者,可考虑电生理评估以识别损伤平面以下周围神经功能障碍。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess factors affecting electrophysiological changes in the peripheral nervous system below the neurologic level of injury (NLI) in patients with subacute spinal cord injury (SCI). DESIGN: Retrospective observational study. SETTING: An inpatient rehabilitation center of a university hospital. PARTICIPANTS: Through reviewing the medical records of 151 subjects with SCI, 42 without any other disease inducing peripheral neurologic abnormalities were included. They were classified into 2 groups, with or without denervation potentials in electromyography (EMG) below NLI. INTERVENTION: Not applicable. MAIN OUTCOME MEASURES: Demographics and clinical characteristics including NLI, American Spinal Injury Association Impairment Scale (AIS), and Lower Extremity Motor Score were compared. Results of electrophysiological study including nerve conduction study, somatosensory-evoked potential (SSEP), and motor-evoked potential (MEP) were compared. RESULTS: Denervation potentials in EMG below NLI were observed in 20 subjects, and 10 of them were AIS A or B, but there was none in subjects without denervation potentials (P<.001). The lower extremity motor score was 4.35±7.74 in the group with denervation potentials, lower than 33.64±13.60 of the opposite group (P<.001). In the analysis of electrophysiological study, patients with denervation potentials showed a higher proportion of no response than patients without denervation potentials (60.0% vs 11.4% in peroneal nerve conduction study, 35.0% vs 2.3% in tibial nerve conduction study, 80.0% vs 18.2% in SSEP, 87.5% vs 22.7% in MEP; P<.001, respectively). Additionally, greater axonal loss, based on decrease of amplitude without delayed latency on nerve conduction study, was observed in the group with denervation potentials than the opposite group (P<.001). CONCLUSION: Among subjects with subacute SCI, cases of peripheral nervous dysfunction below the injury site occur, possibly associated with the severity of SCI.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. Moon CW, Jung IY, Cho KH, et al. Electrophysiological Changes in the Peripheral Nervous System After Subacute Spinal Cord Injury. Arch Phys Med Rehabil. 2020. PMID: 32035142. doi:10.1016/j.apmr.2019.12.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。