3D打印矫形器与低温热塑板矫形器对慢性偏瘫卒中患者腕屈肌痉挛的随机对照试验
这项随机对照试验纳入40例伴腕屈肌痉挛的慢性偏瘫卒中患者,比较常规康复联合3D打印矫形器与联合低温热塑板矫形器的效果。每天佩戴矫形器约4-8小时、持续六周后,3D打印组在改良Ashworth量表评分、腕背伸被动关节活动度、Fugl-Meyer评分及肿胀评分上的改善显著优于对照组。
要点
- 3D打印矫形器在六周时降低腕屈肌痉挛方面优于低温热塑板矫形器(65% vs 30%,P=0.02)。
- 3D打印组在腕背伸被动关节活动度、Fugl-Meyer评分和肿胀评分上也有显著改善。
- 两组在视觉模拟评分和主观感受评分上无显著差异。
核心结论
- 与低温热塑板矫形器相比,3D打印矫形器在减轻痉挛和肿胀、改善腕部运动功能及腕背伸被动活动度方面表现出更大的变化。
研究设计与样本
- 随机对照试验,在康复中心进行,共纳入40例伴腕屈肌痉挛的慢性偏瘫卒中患者。
- 患者随机分为实验组(常规康复治疗+3D打印矫形器,20例)和对照组(常规康复治疗+低温热塑板矫形器,20例)。
- 矫形器佩戴时间约为每天4-8小时,持续六周。
主要发现
- 三周时两组改良Ashworth量表评分变化无显著差异(15% vs 25%,P=0.496)。
- 六周时实验组与对照组在改良Ashworth量表评分(65% vs 30%,P=0.02)、腕背伸被动关节活动度(P<0.001)、尺偏被动关节活动度(P=0.028)、Fugl-Meyer评分(P<0.001)和肿胀评分(P<0.001)上均有显著变化。
- 两组在视觉模拟评分变化(P=0.637)和主观感受评分(P=0.243)上无显著差异。
关键数值与推荐
- 主要结局指标为改良Ashworth量表,在基线、三周和六周评估三次。
- 次要结局指标包括被动关节活动度、Fugl-Meyer评分、视觉模拟评分和肿胀评分,在基线和六周评估两次。
- 主观感受评分在六周时评估。
临床怎么用
- 对于慢性偏瘫卒中伴腕屈肌痉挛患者,可考虑使用3D打印矫形器作为辅助康复手段,每日佩戴约4-8小时、持续六周。
- 3D打印矫形器可能在减轻痉挛和肿胀、改善腕部运动功能及被动活动度方面提供比低温热塑板矫形器更大的获益。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to compare the effects of two kinds of wrist-hand orthosis on wrist flexor spasticity in chronic stroke patients. DESIGN: This is a randomized controlled trial. SETTING: The study was conducted in a rehabilitation center. PARTICIPANTS: A total of 40 chronic hemiparetic stroke patients with wrist flexor spasticity were involved in the study. INTERVENTIONS: Patients were randomly assigned to either an experimental group (conventional rehabilitation therapy + 3D-printed orthosis, 20 patients) or a control group (conventional rehabilitation therapy + low-temperature thermoplastic plate orthosis, 20 patients). The time of wearing orthosis was about 4-8 hours per day for six weeks. MAIN MEASURES: Primary outcome measure: Modified Ashworth Scale was assessed three times (at baseline, three weeks, and six weeks). Secondary outcome measures: passive range of motion, Fugl-Meyer Assessment score, visual analogue scale score, and the swelling score were assessed twice (at baseline and six weeks). The subjective feeling score was assessed at six weeks. RESULTS: No significant difference was found between the two groups in the change of Modified Ashworth Scale scores at three weeks (15% versus 25%, P = 0.496). At six weeks, the Modified Ashworth Scale scores (65% versus 30%, P = 0.02), passive range of wrist extension (P < 0.001), ulnar deviation (P = 0.028), Fugl-Meyer Assessment scores (P < 0.001), and swelling scores (P < 0.001) showed significant changes between the experimental group and the control group. No significant difference was found between the two groups in the change of visual analogue scale scores (P = 0.637) and the subjective feeling scores (P = 0.243). CONCLUSION: 3D-printed orthosis showed greater changes than low-temperature thermoplastic plate orthosis in reducing spasticity and swelling, improving motor function of the wrist and passive range of wrist extension for stroke patients.
引用
- Zheng Y, Liu G, Yu L, et al. Effects of a 3D-printed orthosis compared to a low-temperature thermoplastic plate orthosis on wrist flexor spasticity in chronic hemiparetic stroke patients: a randomized controlled trial. Clin Rehabil. 2019. PMID: 31686529. doi:10.1177/0269215519885174
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。