脑卒中上肢Fugl-Meyer评估的信度研究:条目、亚量表与总分水平
结果显示肩部4个条目存在系统性分歧,条目水平一致性高(79-100%),亚量表和总分在允许13分差异时达到70%一致性,提示FMA-UE在早期亚急性期脑卒中患者中信度良好。
要点
- FMA-UE在早期亚急性期脑卒中患者中评估者内与评估者间信度良好。
- 肩部4个条目存在位置或集中度的系统性分歧,需关注评估一致性。
- 条目水平一致性高(79-100%),亚量表和总分在13分差异内达70%一致性。
核心结论
- FMA-UE在早期亚急性期脑卒中患者中评估者内和评估者间信度均可靠。
研究设计与样本
- 两名物理治疗师在卒中后10天内连续2天独立评估FMA-UE,采用基于秩的配对有序数据统计方法分析一致性、系统性和随机性分歧。
主要发现
- 肩部4个条目检测到位置或集中度的系统性分歧。
- 条目水平评估者内和评估者间一致性高(79-100%)。
- 亚量表和总分在允许13分差异时达到70%一致性。
关键数值与推荐
- 条目水平评估者内和评估者间一致性为79-100%。
- 亚量表和总分在允许13分差异时达到70%一致性。
临床怎么用
- FMA-UE可用于早期亚急性期脑卒中患者上肢感觉运动损伤的可靠评估。
- 评估时需注意肩部条目的系统性分歧,建议加强评估者培训以提高一致性。
- 更广泛的国际使用FMA-UE有助于比较不同地区和国家的脑卒中恢复情况。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The Fugl-Meyer Assessment of Upper Extremity (FMA-UE) is recommended for evaluation of sensorimotor impairment post stroke, but the item-level reliability of the scale is unknown. The study aims to determine intra- and inter-rater reliability of the FMA-UE at item-, subscale- and total score level in patients with early subacute stroke. DESIGN: Intra/inter-rater reliability. SUBJECTS: Sixty consecutively included patients with stroke (mean age 65.9 years) admitted to Central Military Hospital of Colombia, Bogota. METHODS: Two physiotherapists scored FMA-UE independently on 2 consecutive days within 10 days post stroke. A rank-based statistical method for paired ordinal data was used to assess the level of agreement, systematic and random disagreements. RESULTS: Systematic disagreements either in position or concentration were detected in 4 items of the shoulder section. The item level intra- and inter-rater agreement was high (79100%). The 70% agreement was also reached for the subscales and the total score when 13-point difference was accepted. CONCLUSION: The FMA-UE is reliable both within and between raters in patients with stroke in the early subacute phase. A wider international use of FMA-UE will allow comparison of stroke recovery between regions and countries and thereby potentially improve the quality of care and rehabilitation in persons with stroke worldwide.
引用
- Hernández ED, Galeano CP, Barbosa NE, et al. Intra- and inter-rater reliability of Fugl-Meyer Assessment of Upper Extremity in stroke. J Rehabil Med. 2019. PMID: 31448807. doi:10.2340/16501977-2590
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。