文献速递神经康复

脑卒中上肢Fugl-Meyer评估的信度研究:条目、亚量表与总分水平

Intra- and inter-rater reliability of Fugl-Meyer Assessment of Upper Extremity in stroke.
PubMed 文献 · J Rehabil Med · 2019-01-01

结果显示肩部4个条目存在系统性分歧,条目水平一致性高(79-100%),亚量表和总分在允许13分差异时达到70%一致性,提示FMA-UE在早期亚急性期脑卒中患者中信度良好。

要点

  • FMA-UE在早期亚急性期脑卒中患者中评估者内与评估者间信度良好。
  • 肩部4个条目存在位置或集中度的系统性分歧,需关注评估一致性。
  • 条目水平一致性高(79-100%),亚量表和总分在13分差异内达70%一致性。

核心结论

  • FMA-UE在早期亚急性期脑卒中患者中评估者内和评估者间信度均可靠。

研究设计与样本

  • 两名物理治疗师在卒中后10天内连续2天独立评估FMA-UE,采用基于秩的配对有序数据统计方法分析一致性、系统性和随机性分歧。

主要发现

  • 肩部4个条目检测到位置或集中度的系统性分歧。
  • 条目水平评估者内和评估者间一致性高(79-100%)。
  • 亚量表和总分在允许13分差异时达到70%一致性。

关键数值与推荐

  • 条目水平评估者内和评估者间一致性为79-100%。
  • 亚量表和总分在允许13分差异时达到70%一致性。

临床怎么用

  • FMA-UE可用于早期亚急性期脑卒中患者上肢感觉运动损伤的可靠评估。
  • 评估时需注意肩部条目的系统性分歧,建议加强评估者培训以提高一致性。
  • 更广泛的国际使用FMA-UE有助于比较不同地区和国家的脑卒中恢复情况。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The Fugl-Meyer Assessment of Upper Extremity (FMA-UE) is recommended for evaluation of sensorimotor impairment post stroke, but the item-level reliability of the scale is unknown. The study aims to determine intra- and inter-rater reliability of the FMA-UE at item-, subscale- and total score level in patients with early subacute stroke. DESIGN: Intra/inter-rater reliability. SUBJECTS: Sixty consecutively included patients with stroke (mean age 65.9 years) admitted to Central Military Hospital of Colombia, Bogota. METHODS: Two physiotherapists scored FMA-UE independently on 2 consecutive days within 10 days post stroke. A rank-based statistical method for paired ordinal data was used to assess the level of agreement, systematic and random disagreements. RESULTS: Systematic disagreements either in position or concentration were detected in 4 items of the shoulder section. The item level intra- and inter-rater agreement was high (79100%). The 70% agreement was also reached for the subscales and the total score when 13-point difference was accepted. CONCLUSION: The FMA-UE is reliable both within and between raters in patients with stroke in the early subacute phase. A wider international use of FMA-UE will allow comparison of stroke recovery between regions and countries and thereby potentially improve the quality of care and rehabilitation in persons with stroke worldwide.

来源:J Rehabil Med,查看原文。版权归原作者所有。

引用

  1. Hernández ED, Galeano CP, Barbosa NE, et al. Intra- and inter-rater reliability of Fugl-Meyer Assessment of Upper Extremity in stroke. J Rehabil Med. 2019. PMID: 31448807. doi:10.2340/16501977-2590

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。