空间分布序贯电刺激改善截瘫患者动态伸膝功率与疲劳
该案例系列研究比较了空间分布序贯刺激(SDSS)与常规单电极刺激(SES)在4例运动感觉完全性脊髓损伤(AIS A)患者动态等速伸膝任务中的表现。SDSS在所有参与者中均产生更高的平均功率,且3例疲劳抵抗更优,1例更差,提示SDSS可能改善FES骑行中的功率输出。
要点
- SDSS在全部4例SCI患者中均提高伸膝平均功率,增幅18%–132%。
- SDSS在3例患者中疲劳指数更优,1例更差,可能与肌肉激活水平低有关。
- 结果支持SDSS在SCI康复FES任务中的潜在应用,但需更大样本验证。
核心结论
- SDSS在4例完全性SCI患者中均一致提高初始和总体伸膝平均功率。
- SDSS的疲劳抵抗在3例中更优,1例更差,该例肌肉激活水平很低。
研究设计与样本
- 采用案例系列设计,纳入4例运动感觉完全性SCI(AIS A)患者。
- 对双侧股外侧肌和股内侧肌分别用SES和SDSS刺激6分钟,在110度/秒角速度下测伸膝力矩。
主要发现
- SDSS相比SES,所有伸膝动作平均功率增幅为P1 132%、P2 100%、P3 36%、P4 18%。
- 初始阶段平均功率增幅分别为P1 84%、P2 59%、P3 66%、P4 16%。
- 疲劳指数SDSS vs SES分别为P1 0.47 vs 0.35、P2 0.63 vs 0.49、P3 0.90 vs 0.82、P4 0.59 vs 0.77。
临床怎么用
- 在SCI患者进行FES辅助伸膝或骑行训练时,可考虑采用SDSS以提升功率输出。
- 对肌肉激活水平很低的患者,SDSS的疲劳抵抗可能不如SES,需个体化选择。
局限性
- 样本量仅4例,为案例系列设计,结论需更大队列研究验证。
- 仅评估动态等速伸膝任务,未涉及其他功能动作或长期训练效果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: During functional electrical stimulation (FES) tasks with able-bodied (AB) participants, spatially distributed sequential stimulation (SDSS) has demonstrated substantial improvements in power output and fatigue properties compared to conventional single electrode stimulation (SES). The aim of this study was to compare the properties of SDSS and SES in participants with spinal cord injury (SCI) in a dynamic isokinetic knee extension task simulating knee movement during recumbent cycling. METHOD: Using a case-series design, m. vastus lateralis and medialis of four participants with motor and sensory complete SCI (AIS A) were stimulated for 6 min on both legs with both electrode setups. With SES, target muscles were stimulated by a pair of electrodes. In SDSS, the distal electrodes were replaced by four small electrodes giving the same overall stimulation frequency and having the same total surface area. Torque was measured during knee extension by a dynamometer at an angular velocity of 110 deg/s. Mean power of the left and right sides (PmeanL,R) was calculated from all stimulated extensions for initial, final and all extensions. Fatigue is presented as an index value with respect to initial power from 1 to 0, whereby 1 means no fatigue. RESULTS: SDSS showed higher PmeanL,R values for all four participants for all extensions (increases of 132% in participant P1, 100% in P2, 36% in P3 and 18% in P4 compared to SES) and for the initial phase (increases of 84%, 59%, 66%, and 16%, respectively). Fatigue resistance was better with SDSS for P1, P2 and P4 but worse for P3 (0.47 vs 0.35, 0.63 vs 0.49, 0.90 vs 0.82 and 0.59 vs 0.77, respectively). CONCLUSION: Consistently higher PmeanL,R was observed for all four participants for initial and overall contractions using SDSS. This supports findings from previous studies with AB participants. Fatigue properties were better in three of the four participants. The lower fatigue resistance with SDSS in one participant may be explained by a very low muscle activation level in this case. Further investigation in a larger cohort is warranted.
引用
- Laubacher M, Aksoez EA, Brust AK, et al. Stimulation of paralysed quadriceps muscles with sequentially and spatially distributed electrodes during dynamic knee extension. J Neuroeng Rehabil. 2019. PMID: 30616683. doi:10.1186/s12984-018-0471-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。