Brief-BESTest在慢性阻塞性肺疾病患者中的评定者间与评定者内信度
结果显示评定者间与评定者内信度分别为0.86和0.96,Brief-BESTest评分与6分钟步行距离及五次坐立试验时间呈中度相关。
要点
- Brief-BESTest在COPD患者中评定者间信度0.86、评定者内信度0.96。
- Brief-BESTest评分与6分钟步行距离呈中度正相关(r=0.49,P<0.01)。
- Brief-BESTest评分与五次坐立试验时间呈中度负相关(r=-0.54,P<0.01)。
核心结论
- Brief-BESTest在COPD患者中测量平衡具有良好的评定者间和评定者内信度。
- Brief-BESTest平衡评分与该人群功能运动能力和功能性下肢力量呈中度相关。
研究设计与样本
- 前瞻性、单组、观察性研究,在门诊肺康复项目中开展。
- 参与者由两名独立物理治疗师在两天内完成三次Brief-BESTest评估,并完成肺功能测试、两次6分钟步行测试、五次坐立试验和跌倒效能量表国际问卷。
主要发现
- 评定者间信度组内相关系数为0.86,评定者内信度组内相关系数为0.96。
- Brief-BESTest评分与6分钟步行距离呈中度相关(r=0.49,P<0.01)。
- Brief-BESTest评分与五次坐立试验时间呈中度负相关(r=-0.54,P<0.01)。
- 本研究共完成90次测试,未报告不良事件。
临床怎么用
- Brief-BESTest可用于COPD患者平衡功能的可靠评估,适合由不同评定者重复使用。
- Brief-BESTest评分可辅助反映COPD患者的功能运动能力和功能性下肢力量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE:: To investigate the inter-rater and intra-rater reliability of the Brief Balance Evaluation System Test (Brief-BESTest) in people with chronic obstructive pulmonary disease and its correlation between the Brief-BESTest score and lung function, functional exercise capacity, functional lower limb strength, and fear of falling. DESIGN:: Prospective, single-group, observational study. SETTING:: Outpatient pulmonary rehabilitation program. SUBJECTS:: People with chronic obstructive pulmonary disease who were attending a pulmonary rehabilitation program. INTERVENTION:: Participants performed three Brief-BESTests on two separate days, assessed by two independent physiotherapists. Participants also performed a lung function test, two 6-minute walk tests, the five sit-to-stand test and completed the Fall Efficacy Scale International questionnaire. RESULTS:: Thirty participants (mean (SD) age was 72 (7), forced expiratory volume in 1 second % predicted was 47 (16%), and baseline 6-minute walk distance was 427 (90) meters) completed the study. The interclass coefficients of the inter-rater and intra-rater reliability were 0.86 and 0.96, respectively. The Brief-BESTest score was moderately correlated with the 6-minute walk distance ( r = 0.49, P < 0.01) and the five sit-to-stand test time ( r =-0.54, P < 0.01). No adverse events were reported after the completion of 90 tests in this study. CONCLUSION:: The Brief-BESTest was shown to have good inter- and intra-rater reliability for measuring balance in people with chronic obstructive pulmonary disease. A moderate correlation was demonstrated between the Brief-BESTest balance score with functional exercise capacity and functional lower limb strength in this population.
引用
- Leung RWM, Alison JA, McKeough ZJ, et al. Inter-rater and intra-rater reliability of the Brief-BESTest in people with chronic obstructive pulmonary disease. Clin Rehabil. 2018. PMID: 30086676. doi:10.1177/0269215518792044
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。