文献速递言语与吞咽障碍神经康复

柠檬酸反射性咳嗽试验峰咳嗽流量预测吞咽障碍患者吸入性肺炎的截断值

Determining Peak Cough Flow Cutoff Values to Predict Aspiration Pneumonia Among Patients With Dysphagia Using the Citric Acid Reflexive Cough Test.
PubMed 文献 · Arch Phys Med Rehabil · 2018-07-05

该回顾性研究纳入163例首次诊断为脑血管病所致吞咽障碍的患者,在完成仪器性吞咽评估当天进行0.28 mol/L柠檬酸反射性咳嗽试验,测定峰咳嗽流量。受试者工作特征曲线分析显示,峰咳嗽流量截断值59 L/min与吸入性肺炎显著相关(AUC 0.88,95%CI 0.83-0.93),比值比为21.56(95%CI 9.62-48.28,P<.001),且将其纳入多因素模型可显著提升发病6个月内吸入性肺炎的预测能力(AUC 0.91 vs 0.79)。

要点

  • 柠檬酸反射性咳嗽试验峰咳嗽流量<59 L/min的吞咽障碍患者,发病6个月内吸入性肺炎风险显著增高。
  • 该截断值预测吸入性肺炎的AUC为0.88(95%CI 0.83-0.93),比值比21.56(95%CI 9.62-48.28,P<.001)。
  • 将峰咳嗽流量加入含吞咽障碍严重度、低体重指数和认知下降的模型,预测AUC从0.79提升至0.91。

核心结论

  • 反射性咳嗽强度低于59 L/min的吞咽障碍患者,在发病后6个月内可能面临较高的呼吸道感染风险。
  • 客观测量反射性咳嗽强度有助于预测吸入性肺炎风险。

研究设计与样本

  • 回顾性分析前瞻性维护数据库,纳入163例首次诊断为脑血管病所致吞咽障碍的患者。
  • 患者在完成仪器性吞咽评估(视频透视或功能性内镜吞咽检查)当天进行0.28 mol/L柠檬酸反射性咳嗽试验。

主要发现

  • 受试者工作特征曲线分析显示,峰咳嗽流量截断值59 L/min与吸入性肺炎显著相关,AUC为0.88(95%CI 0.83-0.93)。
  • 该截断值显著预测吸入性肺炎风险,比值比为21.56(95%CI 9.62-48.28,P<.001)。
  • 多因素logistic回归模型包含初始吞咽障碍严重度、低体重指数和认知水平下降,加入峰咳嗽流量后预测6个月内吸入性肺炎的AUC从0.79提升至0.91。

关键数值与推荐

  • 柠檬酸反射性咳嗽试验浓度:0.28 mol/L。
  • 峰咳嗽流量预测吸入性肺炎的截断值:59 L/min。
  • 截断值59 L/min对应的AUC:0.88(95%CI 0.83-0.93)。
  • 截断值59 L/min预测吸入性肺炎的比值比:21.56(95%CI 9.62-48.28,P<.001)。
  • 加入峰咳嗽流量后多因素模型预测6个月内吸入性肺炎的AUC:0.91(未加入时为0.79)。

临床怎么用

  • 对脑血管病所致吞咽障碍患者,可在仪器性吞咽评估当天行柠檬酸反射性咳嗽试验测定峰咳嗽流量。
  • 峰咳嗽流量低于59 L/min提示发病6个月内吸入性肺炎高风险,可据此加强监测与预防性干预。

局限性

  • 本研究为回顾性分析,样本来自单中心大学附属医院,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the clinical usefulness of the peak cough flow generated during the citric acid reflexive cough test (0.28 mol/L) by determining the appropriate cutoff values that could accurately predict aspiration pneumonia within the first 6 months after onset. DESIGN: Retrospective analysis of a prospectively maintained database. SETTING: University-affiliated hospital. PARTICIPANTS: Patients (N=163) with first-ever diagnosed dysphagia attributable to cerebrovascular disease, who had undergone the citric acid reflexive cough test on the same day they underwent the instrumental assessment of swallowing, such as videofluoroscopy or the functional endoscopic swallowing test. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Peak cough flow (L/min) from the citric acid reflexive cough test. RESULTS: A final 163 patients had full medical records with 6-month follow-up. Receiver operating curve analysis showed that peak cough flow cutoff values set at 59 L/min were significantly associated with aspiration pneumonia (area under the curve [AUC] 95% confidence interval =0.88 [0.83-0.93]). This cutoff value significantly (P<.001) predicted the risk of aspiration pneumonia with an odds ratio of 21.56 (9.62-48.28). A multivariate regression logistic regression analysis model including initial dysphagia severity, low body mass index, and decreased level of cognition showed that inclusion of the peak cough flow from the citric acid reflexive cough test significantly improved the predictive model of aspiration pneumonia within the first 6 months after onset (AUC=0.91 vs 0.79). CONCLUSIONS: Those with reflexive cough strength less than 59 L/min may be at high risk of respiratory infections within the first 6 months after dysphagia onset. Objective measurement of reflexive cough strength may help to predict those at risk of aspiration pneumonia.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. Sohn D, Park GY, Koo H, et al. Determining Peak Cough Flow Cutoff Values to Predict Aspiration Pneumonia Among Patients With Dysphagia Using the Citric Acid Reflexive Cough Test. Arch Phys Med Rehabil. 2018. PMID: 29981313. doi:10.1016/j.apmr.2018.06.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。