文献速递脊髓损伤康复

脊髓损伤患者腕部加速度计身体活动测量:需要个体化校准切点

Wrist Accelerometry for Physical Activity Measurement in Individuals With Spinal Cord Injury-A Need for Individually Calibrated Cut-Points.
PubMed 文献 · Arch Phys Med Rehabil · 2017-12-06

该研究针对20名慢性脊髓损伤手动轮椅使用者,通过分级 treadmill-wheeling 测试建立个体和群体腕部加速度计中高强度身体活动(MVPA)切点,并进行6天监测。个体切点范围为6040至21540 VM-CPM,群体切点为11652(95%CI 7395-15909)。Bland-Altman分析显示个体与群体切点计算的总日MVPA差异较大,建议对该人群进行个体化校准。

要点

  • 脊髓损伤患者腕部加速度计MVPA切点个体差异大,需个体化校准。
  • 群体切点11652 VM-CPM可能导致总MVPA分钟数出现较大偏差。
  • 推荐使用个体校准的腕部加速度计进行习惯性身体活动监测。

核心结论

  • 建议对脊髓损伤患者使用个体化校准的腕部加速度计切点来有效监测习惯性身体活动。

研究设计与样本

  • 研究对象为20名慢性(>1年)脊髓损伤手动轮椅使用者,年龄31-64岁,损伤水平C5至L2。
  • 参与者完成分级treadmill-wheeling测试,同时测量氧耗、腕部加速度向量幅值和辐条加速度。
  • 通过线性回归确定个体MVPA切点(≥3 SCI METs对应的VM-CPM),多层线性回归确定群体切点,随后进行6天监测。

主要发现

  • 个体MVPA切点范围为6040至21540 VM-CPM,群体切点为11652(95%CI 7395-15909)。

关键数值与推荐

  • MVPA定义为≥3 SCI METs。
  • 个体切点范围6040-21540 VM-CPM,群体切点11652(95%CI 7395-15909)。

临床怎么用

  • 在脊髓损伤患者身体活动监测中,应进行个体化腕部加速度计校准以提高MVPA评估准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To create and compare individual and group-based cut-points for wrist accelerometry that correspond to moderate-to-vigorous physical activity (MVPA) in people with spinal cord injury (SCI). DESIGN: Participants completed a graded treadmill-wheeling test while being assessed for oxygen consumption, wrist-acceleration vector magnitude, and spoke acceleration. Oxygen consumption was converted to SCI metabolic equivalents (METs), and linear regression was applied to determine an individualized vector magnitude cut-point (counts per minute, VM-CPM) corresponding with MVPA (≥3 SCI METs). Multilevel linear regression was applied to determine a group MVPA cut-point. Participants then completed a 6-day monitoring period while wearing the accelerometers. SETTING: A local SCI research center. PARTICIPANTS: Manual wheelchair users (N=20; aged 31-64y; injury levels, C5 to L2) with chronic (>1y) SCI. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Mean total daily MVPA, wheeled MVPA, and nonwheeled MVPA were calculated using both the individual and group cut-points. Agreement on measures of minutes per day of MVPA between the individual and group mean cut-point method was assessed using Bland-Altman plots. RESULTS: Individual cut-points for MVPA ranged from 6040 to 21,540 VM-CPM, with a group cut-point of 11,652 (95% confidence interval, 7395-15,909). For total daily MVPA, Bland-Altman analysis revealed a bias of .22±33.0 minutes, with 95% limits of agreement from -64.5 to 64.9 minutes, suggesting a large discrepancy between total MVPA calculated from individual and group mean cut-points. CONCLUSIONS: Individual calibration of wrist-worn accelerometry is recommended for effective habitual PA monitoring in this population.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. McCracken LA, Ma JK, Voss C, et al. Wrist Accelerometry for Physical Activity Measurement in Individuals With Spinal Cord Injury-A Need for Individually Calibrated Cut-Points. Arch Phys Med Rehabil. 2017. PMID: 29222006. doi:10.1016/j.apmr.2017.10.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。