脑损伤后上肢够取运动康复的自适应混合机器人系统可用性研究
本研究从技术与临床角度评估一套由被动外骨骼和功能性电刺激组成的混合机器人系统用于脑损伤后上肢够取运动康复的可用性。系统采用反馈误差学习控制器调节电刺激强度。健康受试者(N=12)中追踪误差显著降低;脑损伤患者(N=4)中误差轨迹呈下降趋势、任务表现呈上升趋势,患者对系统接受度和满意度高。
要点
- 混合机器人系统结合被动外骨骼与FES,采用反馈误差学习控制器辅助够取训练。
- 健康受试者中追踪误差显著降低,支持控制器技术可行性。
- 脑损伤患者中误差轨迹下降、任务表现上升,且接受度和满意度高。
核心结论
- 研究证明使用混合机器人系统进行够取康复在技术上是可行的。
- 患者报告显示对混合机器人系统干预高度满意和接受。
研究设计与样本
- 系统由被动外骨骼支撑手臂重量和功能性电刺激装置辅助够取任务组成。
- 反馈误差学习控制器基于比例-积分-微分反馈控制器和人工神经网络前馈控制器调节靶肌肉电刺激强度。
- 实验一在健康受试者(N=12)中评估控制器技术可行性与性能。
- 实验二在脑损伤患者(N=4)中进行两次实验会话评估系统性能及用户满意度和情绪反应。
主要发现
- 健康受试者实验中,执行够取运动时追踪误差显著降低。
- 患者实验中,随着运动重复,误差轨迹呈下降趋势且任务表现呈上升趋势。
- 脑损伤患者对使用该系统作为康复工具表现出高度接受。
临床怎么用
- 该系统可作为脑损伤后上肢够取运动康复的技术可行方案。
- 反馈误差学习控制器可根据用户表现调节电刺激强度以辅助够取训练。
局限性
- 患者样本量小(N=4),仅进行两次实验会话。
- 研究为回顾性试验注册(ISRCTN12843006)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Brain injury survivors often present upper-limb motor impairment affecting the execution of functional activities such as reaching. A currently active research line seeking to maximize upper-limb motor recovery after a brain injury, deals with the combined use of functional electrical stimulation (FES) and mechanical supporting devices, in what has been previously termed hybrid robotic systems. This study evaluates from the technical and clinical perspectives the usability of an integrated hybrid robotic system for the rehabilitation of upper-limb reaching movements after a brain lesion affecting the motor function. METHODS: The presented system is comprised of four main components. The hybrid assistance is given by a passive exoskeleton to support the arm weight against gravity and a functional electrical stimulation device to assist the execution of the reaching task. The feedback error learning (FEL) controller was implemented to adjust the intensity of the electrical stimuli delivered on target muscles according to the performance of the users. This control strategy is based on a proportional-integral-derivative feedback controller and an artificial neural network as the feedforward controller. Two experiments were carried out in this evaluation. First, the technical viability and the performance of the implemented FEL controller was evaluated in healthy subjects (N = 12). Second, a small cohort of patients with a brain injury (N = 4) participated in two experimental session to evaluate the system performance. Also, the overall satisfaction and emotional response of the users after they used the system was assessed. RESULTS: In the experiment with healthy subjects, a significant reduction of the tracking error was found during the execution of reaching movements. In the experiment with patients, a decreasing trend of the error trajectory was found together with an increasing trend in the task performance as the movement was repeated. Brain injury patients expressed a great acceptance in using the system as a rehabilitation tool. CONCLUSIONS: The study demonstrates the technical feasibility of using the hybrid robotic system for reaching rehabilitation. Patients' reports on the received intervention reveal a great satisfaction and acceptance of the hybrid robotic system. TRIAL REGISTRATION: Retrospective trial registration in ISRCTN Register with study ID ISRCTN12843006 .
引用
- Resquín F, Gonzalez-Vargas J, Ibáñez J, et al. Adaptive hybrid robotic system for rehabilitation of reaching movement after a brain injury: a usability study. J Neuroeng Rehabil. 2017. PMID: 29025427. doi:10.1186/s12984-017-0312-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。