慢性阻塞性肺疾病患者短时下肢功能运动测试的测量特性:系统综述
该系统综述评估了慢性阻塞性肺疾病(COPD)患者短时(<6分钟)下肢功能运动测试的信度、效度和反应性。0.82)及肺康复后反应性在较虚弱COPD患者中最佳。定时「起立-行走」测试(TUG)支持使用练习测试,并能区分跌倒史和低6分钟步行距离(AUC=0.77;0.82)。
要点
- 4MGS和5STS作为分层工具效度好(AUC=0.72-0.87;0.82)。
- TUG支持练习测试,可区分跌倒史和低6分钟步行距离(AUC=0.77;0.82)。
核心结论
- 所选短时功能运动测试可补充已建立的运动能力测量,用于分层和测量变化反应性,尤其在功能能力较低的COPD患者中。
研究设计与样本
- 系统综述,检索MEDLINE、Embase、Scopus、AMED和CINAHL五个数据库。
- 纳入报告COPD患者短时(<6分钟)下肢功能运动测试心理测量特性的研究。
- 两名评价者独立提取数据,并使用COSMIN对每个测量特性进行质量评级。
主要发现
- 4MGS和5STS作为分层工具的效度(AUC=0.72-0.87;0.82)及肺康复后反应性在较虚弱COPD患者中最佳。
- TUG研究支持使用练习测试,并能区分跌倒史和低6分钟步行距离(AUC=0.77;0.82,COSMIN评级=fair-excellent)。
关键数值与推荐
- 4MGS和5STS分层效度AUC=0.72-0.87和0.82。
- TUG区分跌倒史和低6分钟步行距离的AUC=0.77和0.82(COSMIN评级fair-excellent)。
临床怎么用
- 4MGS和5STS可用于COPD患者的分层评估和肺康复后变化测量,尤其适用于功能能力较低者。
- TUG测试建议先进行练习测试,可用于筛查跌倒史和低6分钟步行距离。
局限性
- 早期研究受样本量小限制。
- 步态测试和两分钟步行测试的数据有限且研究质量较低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: An increasing variety of short functional exercise tests are reported in people with chronic obstructive pulmonary disease (COPD). Systematic review of the psychometric properties of these exercise tests is indicated. PURPOSE: The aim of this study was to determine the reliability, validity, and responsiveness of short (duration < 6 min) lower extremity functional exercise tests in people with COPD. DATA SOURCES: Five databases were searched: MEDLINE, Embase, Scopus, AMED, and CINAHL. STUDY SELECTION: Studies reporting psychometric properties of short functional exercise tests in people with COPD were included. DATA EXTRACTION: Two reviewers independently extracted data and rated the quality of each measurement property using the COnsensus-based Standards for the Selection of Health Measurement INstrument (COSMIN). DATA SYNTHESIS: Twenty-nine studies were identified reporting properties of 11 different tests. Four-meter gait speed [4MGS] and 5 repetition sit-to-stand [5STS] demonstrated high reliability (ICC = .95-.99; .97) with no learning effect (COSMIN study ratings = good--excellent). Their validity for use as a stratification tool anchored against an established prognostic indicator (area under receiver operator characteristics curve [AUC] = 0.72-0.87; 0.82) and responsiveness to change after pulmonary rehabilitation was greatest in more frail people with COPD. Studies of the Timed "Up and Go" [TUG] test support use of a practice test and show discriminative ability to detect falls history and low six-minute walk distance (AUC = 0.77; 0.82, COSMIN ratings = fair-excellent). LIMITATIONS: Earlier studies were limited by small sample size. Limited data of lower study quality was identified for step tests and the Two-Minute Walk Test. CONCLUSIONS: Selected short functional exercise tests can complement established exercise capacity measures, in stratification and measuring responsiveness to change especially in people with COPD and lower functional ability.
引用
- Johnston KN, Potter AJ, Phillips A, et al. Measurement Properties of Short Lower Extremity Functional Exercise Tests in People With Chronic Obstructive Pulmonary Disease: Systematic Review. Phys Ther. 2017. PMID: 28605481. doi:10.1093/ptj/pzx063
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。