文献速递神经康复

无标记动作捕捉系统作为神经康复训练设备的系统综述

Markerless motion capture systems as training device in neurological rehabilitation: a systematic review of their use, application, target population and efficacy.
PubMed 文献 · J Neuroeng Rehabil · 2017-06-24

最常用设备为Microsoft Kinect,训练多用于卒中后上肢康复,训练方案在强度、频率和内容上差异较大,且无研究采用以患者为中心的任务导向训练。

要点

  • Microsoft Kinect是最常用的无标记动作捕捉训练设备
  • 训练多针对卒中后上肢康复,方案异质性大
  • 无研究采用以患者为中心的任务导向训练

核心结论

  • 无标记动作捕捉系统是神经康复中有潜力的训练设备,可增加训练动机并可能改善ICF一个或多个层面。
  • 尽管以患者为中心的任务导向训练很重要,但纳入研究中未包含该方法。
  • 未来需将动作捕捉系统与以患者为中心的任务导向方法结合,并用随机对照试验和长期随访验证疗效。

研究设计与样本

  • 系统综述,检索PubMed、Cinahl、Cochrane Database和IEEE四个数据库。
  • 基于方法学质量,选择6项研究分析训练效果。

主要发现

  • 最常用的动作捕捉系统是Microsoft Kinect。
  • 训练主要在卒中后上肢康复中开展。
  • 训练方案在强度、频率和内容上存在差异。
  • 无研究报告基于以患者为中心方法的个体化训练方案。

关键数值与推荐

  • 平均Van Tulder质量评分为8.06±3.67。

临床怎么用

  • 可考虑使用无标记动作捕捉系统(如Microsoft Kinect)作为神经康复训练辅助设备以增加动机。
  • 应用时需注意现有训练方案异质性大,且缺乏以患者为中心的任务导向设计。

局限性

  • 纳入研究方法学质量平均分8.06±3.67,仅6项用于训练效果分析。
  • 训练方案在强度、频率和内容上差异大,无法汇总统一参数。
  • 无研究采用以患者为中心的任务导向方法。
  • 缺乏随机对照试验和长期随访证据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Client-centred task-oriented training is important in neurological rehabilitation but is time consuming and costly in clinical practice. The use of technology, especially motion capture systems (MCS) which are low cost and easy to apply in clinical practice, may be used to support this kind of training, but knowledge and evidence of their use for training is scarce. The present review aims to investigate 1) which motion capture systems are used as training devices in neurological rehabilitation, 2) how they are applied, 3) in which target population, 4) what the content of the training and 5) efficacy of training with MCS is. METHODS: A computerised systematic literature review was conducted in four databases (PubMed, Cinahl, Cochrane Database and IEEE). The following MeSH terms and key words were used: Motion, Movement, Detection, Capture, Kinect, Rehabilitation, Nervous System Diseases, Multiple Sclerosis, Stroke, Spinal Cord, Parkinson Disease, Cerebral Palsy and Traumatic Brain Injury. The Van Tulder's Quality assessment was used to score the methodological quality of the selected studies. The descriptive analysis is reported by MCS, target population, training parameters and training efficacy. RESULTS: Eighteen studies were selected (mean Van Tulder score = 8.06 ± 3.67). Based on methodological quality, six studies were selected for analysis of training efficacy. Most commonly used MCS was Microsoft Kinect, training was mostly conducted in upper limb stroke rehabilitation. Training programs varied in intensity, frequency and content. None of the studies reported an individualised training program based on client-centred approach. CONCLUSION: Motion capture systems are training devices with potential in neurological rehabilitation to increase the motivation during training and may assist improvement on one or more International Classification of Functioning, Disability and Health (ICF) levels. Although client-centred task-oriented training is important in neurological rehabilitation, the client-centred approach was not included. Future technological developments should take up the challenge to combine MCS with the principles of a client-centred task-oriented approach and prove efficacy using randomised controlled trials with long-term follow-up. TRIAL REGISTRATION: Prospero registration number 42016035582 .

来源:J Neuroeng Rehabil,查看原文。版权归原作者所有。

引用

  1. Knippenberg E, Verbrugghe J, Lamers I, et al. Markerless motion capture systems as training device in neurological rehabilitation: a systematic review of their use, application, target population and efficacy. J Neuroeng Rehabil. 2017. PMID: 28646914. doi:10.1186/s12984-017-0270-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。