  • CAMS包含管理者、员工和失语症患者三套调查问卷。
  • 患者版信度较低,多数条目ICC在0.4-0.6之间。

核心结论

  • CAMS或可为有意改善卒中失语症患者照护的医疗机构提供有用的质量改进信息。

研究设计与样本

  • 调查工具开发与评价研究,遵循公认指南,包括条目生成与精简、调查格式与组成、预测试、试点测试和信度评估。
  • 调查开发使用31名便利样本参与者,CAMS信度研究使用63名参与者(6名管理者、32名一线员工、25名失语症患者)。
  • 信度研究邀请对象包括安大略省45家社区组织的个体及实践社区的4400名个体。

主要发现

  • 开发出CAMS工具,由3套调查组成,分别从管理者/政策制定者、员工/一线卫生服务提供者和失语症患者(使用沟通可及版本)视角设计。
  • CAMS-患者版信度较低,多数条目ICC在0.4至0.6之间。

关键数值与推荐

  • CAMS-患者版多数条目ICC在0.4至0.6之间。

临床怎么用

  • CAMS可用于医疗机构从管理者、员工和患者三个视角评估卒中失语症患者的沟通可及性并支持质量改进。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To (1) develop a systems-level quality improvement tool targeting communicative access to information and decision-making for stroke patients with language disorders; and (2) evaluate the resulting tool-the Communicative Access Measures for Stroke (CAMS). DESIGN: Survey development and evaluation was in line with accepted guidelines and included item generation and reduction, survey formatting and composition, pretesting, pilot testing, and reliability assessment. SETTING: Development and evaluation were carried out in hospital and community agency settings. PARTICIPANTS: The project used a convenience sample of 31 participants for the survey development, and 63 participants for the CAMS reliability study (broken down into 6 administrators/managers, 32 frontline staff, 25 participants with aphasia). Eligible participants invited to the reliability study included individuals from 45 community-based organizations in Ontario as well as 4400 individuals from communities of practice. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Data were analyzed using kappa statistics and intraclass correlations for each item score on all surveys. RESULTS: A tool, the CAMS, comprising 3 surveys, was developed for health facilities from the perspectives of (1) administrators/policymakers, (2) staff/frontline health care providers, and (3) patients with aphasia (using a communicatively accessible version). Reliability for items on the CAMS-Administrator and CAMS-Staff surveys was moderate to high (kappa/intraclass correlation coefficients [ICCs], .54-1.00). As expected, reliability was lower for the CAMS-Patient survey, with most items having ICCs between 0.4 and 0.6. CONCLUSIONS: These findings suggest that CAMS may provide useful quality improvement information for health care facilities with an interest in improving care for patients with stroke and aphasia.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. Kagan A, Simmons-Mackie N, Victor JC, et al. Communicative Access Measures for Stroke: Development and Evaluation of a Quality Improvement Tool. Arch Phys Med Rehabil. 2017. PMID: 28535978. doi:10.1016/j.apmr.2017.04.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。