文献速递神经康复

慢性偏瘫卒中患者机器人持续腕关节操作诱发的任务依赖性皮层激活定量研究

Quantification of task-dependent cortical activation evoked by robotic continuous wrist joint manipulation in chronic hemiparetic stroke.
PubMed 文献 · J Neuroeng Rehabil · 2017-04-17

本研究结合机器人腕关节操作与高密度脑电图,评估不同感觉损伤程度的慢性偏瘫卒中患者躯体感觉系统完整性。严重感觉损伤患者被动条件下对侧皮层反应振幅显著降低且与解剖损伤相关;轻度感觉损伤患者主动条件下反应较被动条件降低,而无损伤及无感觉损伤卒中患者无此降低。

要点

  • 机器人持续关节操作可定量评估卒中后躯体感觉通路完整性。
  • 严重感觉损伤患者被动腕操作诱发的对侧皮层反应振幅显著降低。
  • 轻度感觉损伤患者主动任务下皮层反应较被动条件降低。

核心结论

  • 机器人连续关节操作结合高密度脑电图可在执行有意义上肢控制任务时研究躯体感觉皮层诱发反应,并定量评估感觉通路完整性。

研究设计与样本

  • 采用机器人腕关节操作器对患肢施加连续周期性扰动,提供本体感觉和触觉刺激,同时记录高密度脑电图。
  • 在被动任务(放松腕)和主动任务(维持20%最大腕屈)下,以平均反应功率和信噪比量化皮层诱发反应。

主要发现

  • 被动条件下,腕关节操作在无损伤参与者及轻度或无感觉损伤的慢性卒中患者中引起对侧皮层反应。
  • 严重感觉损伤患者皮层反应振幅强烈降低,且与解剖损伤相关。
  • 主动条件下,轻度感觉损伤患者反应较被动条件降低,而无损伤参与者和无感觉损伤卒中患者未出现此降低。

临床怎么用

  • 机器人连续关节操作联合高密度脑电图可用于定量评估卒中后躯体感觉通路完整性。
  • 在运动控制背景下评估感觉通路完整性,可为制定更有效的神经康复疗法提供额外信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cortical damage after stroke can drastically impair sensory and motor function of the upper limb, affecting the execution of activities of daily living and quality of life. Motor impairment after stroke has been thoroughly studied, however sensory impairment and its relation to movement control has received less attention. Integrity of the somatosensory system is essential for feedback control of human movement, and compromised integrity due to stroke has been linked to sensory impairment. METHODS: The goal of this study is to assess the integrity of the somatosensory system in individuals with chronic hemiparetic stroke with different levels of sensory impairment, through a combination of robotic joint manipulation and high-density electroencephalogram (EEG). A robotic wrist manipulator applied continuous periodic disturbances to the affected limb, providing somatosensory (proprioceptive and tactile) stimulation while challenging task execution. The integrity of the somatosensory system was evaluated during passive and active tasks, defined as 'relaxed wrist' and 'maintaining 20% maximum wrist flexion', respectively. The evoked cortical responses in the EEG were quantified using the power in the averaged responses and their signal-to-noise ratio. RESULTS: Thirty individuals with chronic hemiparetic stroke and ten unimpaired individuals without stroke participated in this study. Participants with stroke were classified as having severe, mild, or no sensory impairment, based on the Erasmus modification of the Nottingham Sensory Assessment. Under passive conditions, wrist manipulation resulted in contralateral cortical responses in unimpaired and chronic stroke participants with mild and no sensory impairment. In participants with severe sensory impairment the cortical responses were strongly reduced in amplitude, which related to anatomical damage. Under active conditions, participants with mild sensory impairment showed reduced responses compared to the passive condition, whereas unimpaired and chronic stroke participants without sensory impairment did not show this reduction. CONCLUSIONS: Robotic continuous joint manipulation allows studying somatosensory cortical evoked responses during the execution of meaningful upper limb control tasks. Using such an approach it is possible to quantitatively assess the integrity of sensory pathways; in the context of movement control this provides additional information required to develop more effective neurorehabilitation therapies.

来源:J Neuroeng Rehabil,查看原文。版权归原作者所有。

引用

  1. Vlaar MP, Solis-Escalante T, Dewald JPA, et al. Quantification of task-dependent cortical activation evoked by robotic continuous wrist joint manipulation in chronic hemiparetic stroke. J Neuroeng Rehabil. 2017. PMID: 28412953. doi:10.1186/s12984-017-0240-3