固定距离步行测试用于冠心病患者功能评估的可行性研究
该研究在58例完成心脏康复的稳定冠心病患者中,于三天间隔内依次进行6分钟步行测试(6MWT)、400米舒适速度步行测试(400mCWT)和200米快速步行测试(200mFWT),并关联改良Bruce跑台测试。结果显示三种测试耐受性满意、主要参数信度良好(ICC>0.8);6MWT与400mCWT的VO2无显著差异(P=0.33)且均低于第一通气阈(P<0.001),200mFWT的VO2与第一通气阈无差异。结论认为400mCWT和200mFWT可行、耐受良好且可靠,可探索两个努力强度水平。
要点
- 400mCWT和200mFWT在稳定冠心病患者中可行、耐受良好且可靠。
- 400mCWT可考虑作为6MWT的替代方案。
- 400mCWT与200mFWT联用有助于更好评估体能并个体化运动训练。
核心结论
- 400mCWT和200mFWT可行、耐受良好且可靠,分别探索低于第一通气阈和不低于第一通气阈的两个努力强度水平。
- 400mCWT是6MWT的可能替代方案,与200mFWT联用可更好测量体能并个体化运动训练。
研究设计与样本
- 研究纳入58例完成心脏康复项目的稳定冠心病患者(平均年龄64.85±6.03岁,50名男性)。
- 患者在三天间隔内完成三次步行测试:前两次为舒适速度随机顺序的6MWT和400mCWT,第三次为快速速度的200mFWT。
- 第二阶段的结束时关联改良Bruce跑台测试,监测心率、步行速度和VO2等主要参数。
主要发现
- 三种测试的耐受性满意。
- 主要参数的信度良好(组内相关系数>0.8)。
- 6MWT与400mCWT的VO2无显著差异(P=0.33),且均低于跑台测试确定的第一通气阈(P<0.001):分别为16.2±3.0、16.5±2.6和20.7±5.1 mL·min-1·kg-1。
- 200mFWT的VO2(20.2±3.7 mL·min-1·kg-1)与第一通气阈无差异。
关键数值与推荐
- 6MWT与400mCWT的VO2无显著差异(P=0.33)。
- 6MWT和400mCWT的VO2均低于第一通气阈(P<0.001):16.2±3.0 vs. 16.5±2.6 vs. 20.7±5.1 mL·min-1·kg-1。
- 200mFWT的VO2(20.2±3.7 mL·min-1·kg-1)与第一通气阈无差异。
- 主要参数组内相关系数>0.8。
临床怎么用
- 在稳定冠心病患者心脏康复结束时,可采用400mCWT替代6MWT进行舒适速度功能评估。
- 联合使用400mCWT和200mFWT可评估两个努力强度水平,有助于更个体化地制定运动训练方案。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: There is ambiguity concerning the walk tests available for functional assessment of coronary patients, particularly for the walking speed. This study explores the psychometric properties of two walking tests, based on fixed-distance tests, at comfortable and fast velocity, in stabilized patients at the end of a cardiac rehabilitation program. METHODS: At a three-day interval 58 coronary patients (mean age of 64.85±6.03 years, 50 men) performed three walk tests, the first two at a comfortable speed in a random order (6-minute walk test - 6MWT - and 400-metre comfortable walk test - 400mCWT) and the third at a brisk speed (200-metre fast walk test - 200mFWT). A modified Bruce treadmill test was associated at the end of the second phase. Monitored main parameters were: heart rate, walking velocity, VO2. RESULTS: Tolerance to the 3 tests was satisfactory. The reliability of the main parameters was good (intraclass correlation coefficient>0.8). The VO2 concerning 6MWT and 400mCWT were not significantly different (P=0.33) and were lower to the first ventilatory threshold determined by the stress test (P<0.001): 16.2±3.0 vs. 16.5±2.6 vs. 20.7±5.1mL·min-1·kg-1 respectively. The VO2 of the 200mFWT (20.2±3.7) was not different from the first ventilatory threshold. CONCLUSIONS: 400mCWT and 200mFWT are feasible, well-tolerated and reliable. They explore two levels of effort intensity (lower and not different to the first ventilatory threshold respectively). 400mCWT is a possible alternative to 6MWT. Associated with 200mFWT it should allow a better measurement of physical capacities and better customization of exercise training.
引用
- Morard MD, Besson D, Laroche D, et al. Fixed-distance walk tests at comfortable and fast speed: Potential tools for the functional assessment of coronary patients? Ann Phys Rehabil Med. 2016. PMID: 27915207. doi:10.1016/j.rehab.2016.11.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。