文献速递神经康复

上肢表现评估在脑卒中成人功能性抓握任务中的信度与效度

Reliability and validity of the Upper Limb Performance Assessment for functional prehension tasks in adults with stroke: A prospective study.
PubMed 文献 · Clin Rehabil · 2026-08-25

这项前瞻性验证研究在神经康复中心纳入100名慢性期脑卒中上肢功能障碍成人,由3名训练有素的作业治疗师对视频录制的饮水抓握任务进行上肢表现评估评分。结果显示评估者间信度良好(ICC 0.87–0.97),测量误差为12.56%–15.99%,与Fugl-Meyer评估、Wolf运动功能测试、运动活动日志及功能独立性测量均呈中至强相关,提示该生态化任务型评估具有良好信度、聚合效度与可解释性。

要点

  • 上肢表现评估在慢性脑卒中成人中显示良好评分者间信度(ICC 0.87–0.97)。
  • 测量误差为12.56%–15.99%,未见系统性偏倚。
  • 与FMA-UE、WMFT、MAL及FIM呈中至强聚合效度。

核心结论

  • 上肢表现评估在训练有素的评分者中显示优秀信度、足够聚合效度与可解释性,临床实用性中等。
  • 该工具可作为观察者评分的、基于真实生活场景的功能性抓握表现测量。

研究设计与样本

  • 前瞻性验证研究,在神经康复中心纳入100名慢性期脑卒中上肢功能障碍成人。
  • 由3名训练有素的作业治疗师对视频录制的饮水抓握任务进行上肢表现评估评分。

主要发现

  • 信度指标充分,ICC为0.87–0.97,测量误差为12.56%–15.99%,无系统性偏倚。
  • 在施测时间与成本方面展示了临床实用性。

关键数值与推荐

  • 信度采用组内相关系数与最小差异评价,ICC为0.87–0.97,测量误差为12.56%–15.99%。

临床怎么用

  • 可用于慢性期脑卒中成人真实生活场景下功能性抓握表现的上肢运动评估。
  • 需由训练有素的评分者基于视频录制的标准化抓握任务进行评分。
  • 结果解释时应结合测量误差范围,谨慎判断评分变化是否超出最小差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BackgroundManaging upper limb motor performance in daily living is a challenge for adults with stroke. Current assessments demonstrate limitations for evaluation of personalised activity performance in real environments.ObjectiveTo examine the reliability, validity, clinical utility and interpretability of a standardised ecologically task-based assessment of upper limb motor performance in post-stroke adults using the Upper Limb Performance Assessment.DesignA prospective validation study.SettingA neurorehabilitation centre.Participants100 adults with chronic post-stroke upper limb deficit. Performance was rated by three trained occupational therapists.Main measuresUpper limb movement was analysed through Upper Limb Performance Assessment on a video-recorded prehension drinking task. Prehension was rated for reliability and measurement error with the intra-class correlation coefficient and the minimal difference. Validity was examined with the Fugl-Meyer Assessment for Upper Extremity, the Wolf Motor Function Test, the Motor Activity Log and the Functional Independence Measure according to Spearman's rank correlation coefficient.ResultsReliability demonstrated adequate reliability metrics (intra-class correlation coefficient: 0.87-0.97) and measurement error (12.56%-15.99%) without systematic bias. Convergent validity was strong with the Fugl-Meyer Assessment (Spearman's rank correlation coefficient (ρ)= .76, p < .01), Wolf Motor Function Test (ρ= .72, p < .01), Motor Activity Log (ρ=.67, p < .05) and Functional Independence Measure (ρ=.58, p < .01). Clinical utility for administration time and costs was demonstrated.ConclusionThe Upper Limb Performance Assessment demonstrated excellent reliability among trained raters, adequate convergent validity and interpretability in adults with stroke, demonstrating moderate clinical utility. It presents an interest as an observer-rated performance-based measure of functional prehension in real-life settings.

来源:Clin Rehabil,查看原文。版权归原作者所有。

引用

  1. Lacombe J, Piagno S, Lepage B, et al. Reliability and validity of the Upper Limb Performance Assessment for functional prehension tasks in adults with stroke: A prospective study. Clin Rehabil. 2026. PMID: 42640555. doi:10.1177/02692155261474839

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。