文献速递神经康复儿童康复

动力膝矫形器与铰接踝足矫形器对双瘫型脑瘫患者的生物力学影响:一项初步研究

Biomechanical effects of powered knee orthoses and articulated ankle-foot orthoses in people with diparetic cerebral palsy: a pilot study.
PubMed 文献 · J Neuroeng Rehabil · 2026-07-21

该初步研究纳入3例双瘫型脑瘫伴蹲伏步态患者,在8种实验条件下佩戴动力膝-踝-足矫形器(KAFO)并调节踝足矫形器(AFO)刚度,采用光学运动捕捉与地面反力台采集步行生物力学。结果显示动力膝与AFO刚度均影响踝膝生物力学,最高刚度AFO对踝膝蹲伏改善最大,踝力矩随AFO使用增加,膝力矩在动力KAFO下增加但联合实验AFO时较低。

要点

  • 动力膝与AFO刚度共同影响双瘫型脑瘫蹲伏步态的踝膝生物力学。
  • 最高刚度实验AFO在动力KAFO条件下对踝膝蹲伏改善最大。
  • 踝力矩随AFO使用增加,膝力矩在动力KAFO下增加但联合实验AFO时较低。

核心结论

  • 动力膝和AFO刚度对双瘫型脑瘫患者步行中踝膝生物力学有影响,最高刚度实验AFO对蹲伏改善最大。

研究设计与样本

  • 初步研究纳入3例双瘫型脑瘫致蹲伏步态患者,在8种实验条件下佩戴动力膝-踝-足矫形器步行。
  • 使用可调关节刚度实验AFO,采用光学运动捕捉与地面反力台采集自选速度步行生物力学。

主要发现

  • 动力膝和AFO刚度均影响步行中踝膝生物力学。
  • 动力KAFO条件下,最高刚度实验AFO对踝膝蹲伏改善最大。
  • 踝力矩随AFO使用增加,膝力矩随动力KAFO增加但联合实验AFO时较低。
  • 踝功率未被KAFO和AFO条件一致改善,膝功率随KAFO使用一般增加且动力条件下最高。

临床怎么用

  • 对双瘫型脑瘫蹲伏步态患者,动力KAFO联合较高刚度AFO可能更有利于改善踝膝蹲伏。
  • 使用动力KAFO时需关注膝力矩增加,联合实验AFO可能降低膝力矩。

局限性

  • 本研究为初步研究,仅纳入3例患者,结果需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Diparetic cerebral palsy affects approximately 2 in 1000 people, and can result in gait impairments such as excessive knee flexion and excessive ankle dorsiflexion during the stance phase in gait. Short-term clinical trials using robotic rehabilitation devices have shown gait improvements comparable to invasive multilevel surgery for spastic cerebral palsy. This study aimed to determine if the stiffness of articulated forms of ankle-foot orthoses influences the effectiveness of a powered knee-ankle-foot orthosis on crouch gait reduction. It was hypothesized that AFO stiffness would be an important factor influencing crouch gait in individuals with diparetic cerebral palsy when walking with a powered KAFO. METHODS: A pilot study with three participants with diparetic cerebral palsy causing crouch gait was conducted to evaluate the effects of varying ankle stiffness of ankle-foot orthoses on sagittal plane kinematics and kinetics while walking with a powered-knee knee-ankle-foot orthosis. Experimental ankle foot orthoses were made to enable adjustable joint stiffness during the experiment. Optical motion capture and in-ground force plates were used to capture gait biomechanics during self-selected walking for eight experimental conditions. RESULTS: Overall, the presence or absence of a powered knee and AFO stiffness had an impact on ankle and knee biomechanics during walking. Across conditions using the powered KAFO, the greatest improvement in crouch at both the ankle and knee was observed with the highest-stiffness experimental AFO. Ankle torque increased with AFO use, while knee torque increased with the powered KAFO but was lower when paired with the experimental AFOs. Ankle power was not consistently improved by the KAFO and AFO conditions, while knee power generally increased with KAFO use and was highest in the powered conditions. CONCLUSIONS: This study provides preliminary results on the impact of ankle-foot orthoses in conjunction with a powered knee exoskeleton, and may inform further exploration of treatment of pathological gaits using robotic assistive devices.

来源:J Neuroeng Rehabil,查看原文。版权归原作者所有。

引用

  1. Finnegan S, Juco M, Manocha RHK, et al. Biomechanical effects of powered knee orthoses and articulated ankle-foot orthoses in people with diparetic cerebral palsy: a pilot study. J Neuroeng Rehabil. 2026. PMID: 42482068. doi:10.1186/s12984-026-02098-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。