文献速递神经康复

脑卒中后躯干损伤量表心理测量学特性的系统综述:基于COSMIN方法

The psychometric properties of the Trunk Impairment Scale used after stroke: a systematic review using COSMIN methodology.
PubMed 文献 · Phys Ther · 2026-01-01

结果显示内部一致性证据确定性为低,其余测量特性均为极低确定性;

要点

  • TIS内部一致性证据确定性为低,其余测量特性证据确定性均为极低。
  • 方法学局限包括缺乏单维性检验、假设构建不足和报告质量差。

核心结论

  • 尽管TIS在脑卒中康复中广泛使用,但其心理测量学证据缺乏高质量支持。
  • 需要采用COSMIN对齐方法进一步验证TIS在多样化脑卒中人群中的信度和效度。

研究设计与样本

  • 系统综述采用COSMIN方法学,检索五个电子数据库从建库至2025年1月14日。
  • 使用COSMIN偏倚风险清单评估方法学质量,采用改良GRADE方法评定证据确定性,适当时进行Meta分析。

主要发现

  • 内部一致性证据确定性为低,其余测量特性因方法学局限均为极低确定性。
  • 异质性和偏倚风险降低了上述汇总结果的置信度。

关键数值与推荐

  • 内部一致性证据确定性为低,其余测量特性为极低确定性。

临床怎么用

  • 临床使用TIS评估脑卒中患者躯干损伤时,应知晓其心理测量学证据确定性低至极低。
  • TIS的信度指标(ICC均值0.98)在解释时需考虑异质性和偏倚风险的影响。

局限性

  • 纳入研究存在方法学局限,包括缺乏单维性检验、假设构建不足和报告质量差。
  • 异质性和偏倚风险降低了Meta分析结果的置信度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Although the Trunk Impairment Scale (TIS) is widely used in stroke rehabilitation, the quality and certainty of evidence regarding its measurement properties have been unclear. OBJECTIVE: The objective was to systematically evaluate the measurement properties of the TIS in individuals with stroke, using the COSMIN (COnsensus-based Standards for the selection of health Measurement INstruments) methodology. DATA SOURCES: Five electronic databases (PubMed, EBSCOhost, CINAHL, MEDLINE, and ICHUSHI) were searched from their inception dates to January 14, 2025. STUDY SELECTION: Studies assessing the psychometric properties of the TIS in individuals with stroke were included. DATA EXTRACTION AND SYNTHESIS: The studies' methodological quality was evaluated using the COSMIN Risk of Bias checklist. The certainty of evidence was rated using a modified GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach, and meta-analyses were conducted when appropriate. MAIN OUTCOMES AND MEASURES: The measurement properties evaluated were content validity, structural validity, cross-cultural validity, internal consistency, reliability, measurement error, criterion validity, construct validity, and responsiveness. RESULTS: Thirteen studies from 7 countries met the inclusion criteria, with sample sizes of 28 to 201 participants. Based on the modified GRADE approach, internal consistency showed "low" certainty of evidence, whereas all other measurement properties were rated as "very low" certainty due to methodological limitations, including lack of unidimensionality testing, insufficient hypothesis formulation, and poor reporting. A meta-analysis indicated acceptable pooled Cronbach α-values (mean α = .88) and high intra and interrater reliability (mean intraclass correlation coefficient [ICC] = 0.98), although heterogeneity and risk of bias reduced confidence in these findings. CONCLUSIONS AND RELEVANCE: Despite its widespread use, the TIS lacks high-quality psychometric evidence. Further validation studies using COSMIN-aligned methodology are needed to establish its reliability and validity in diverse stroke populations.

来源:Phys Ther,查看原文。版权归原作者所有。

引用

  1. Eguchi M, Jimbo K, Nomoto M, et al. The psychometric properties of the Trunk Impairment Scale used after stroke: a systematic review using COSMIN methodology. Phys Ther. 2026. PMID: 42391468. doi:10.1093/ptj/pzag066

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。