标准化国际Fugl-Meyer运动功能评估手册(卒中后)
系统综述显示遵循原版FMA的研究信效度强,但最小临床重要差异阈值信息有限。
要点
- 国际共识FMA手册各章节同意率均超过79%,可提高评估一致性。
- 评估者需具备神经康复与临床评估基础,新手应接受含监督下患者实操的结构化培训。
- 遵循原版FMA的研究信效度强,但最小临床重要差异阈值证据有限。
核心结论
- 该国际共识手册为全球FMA实施提供统一基础,有助于可靠数据合并并提高未来试验与临床实践结果可比性。
研究设计与样本
- 每个手册章节以至少75%投票同意为最低接受阈值,并寻求评估者培训共识。
- 通过系统文献综述汇编测量性能证据。
主要发现
- 最终FMA手册每个章节的同意率均大于79%。
- 评估者应具备神经康复和临床评估的坚实基础。
- 新手评估者应接受结构化培训,包括监督下患者实操培训,以确保一致准确评分。
- 遵循原版FMA的既往研究证实信效度强,但最小临床重要差异阈值信息有限。
关键数值与推荐
- 手册各章节最低同意阈值为75%,最终各章节同意率均大于79%。
- 评估者需具备神经康复与临床评估基础,新手应接受含监督下患者实操的结构化培训。
临床怎么用
- 临床采用该国际共识FMA手册统一施测流程,以提高评估一致性。
- 按共识要求选拔并培训评估者,新手完成含监督下患者实操的结构化培训。
- 解读FMA变化时注意最小临床重要差异阈值证据有限。
局限性
- 原文指出既往研究对最小临床重要差异阈值提供的信息有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BackgroundFugl-Meyer Assessment of upper and lower extremity is the recommended primary clinical outcome measure of motor function in stroke rehabilitation. However, variations between different manuals undermine the reliability of the assessment, making it difficult to compare results and pool data across trials and centers.ObjectiveTo develop a consensus-based international Fugl-Meyer Assessment (FMA) manual aligned with the original assessment along with agreed recommendations for assessor training. Additionally, the study aims to provide a critical review of current evidence on the measurement properties.MethodsFourteen experienced health professionals and expert FMA users, working in 3 different continents, 6 countries and 13 research centers, participated in an iterative consensus process to generate a comprehensive agreed FMA manual. Agreement of at least 75% determined by voting was the minimum accepted threshold for each section of the manual. Consensus on assessor training was also sought. The evidence on measurement properties was compiled through a systematic literature review.ResultsGreater than 79% agreement was reached for each section of the final FMA manual. Assessors should have strong foundation in neurorehabilitation and clinical assessment. Novice assessors should undergo structured training including supervised practical training with patients to ensure consistent and accurate scoring. Previous research adherent to the original FMA assessment, confirms strong validity and reliability, but provide limited information of minimal clinically important difference thresholds.ConclusionsThis internationally agreed manual provides a common ground for improved consistency in administration of FMA worldwide and thereby will enable reliable data pooling and increase the comparability of results in future trials and clinical practice.
引用
- Hervé-Colas J, Newton SP, Engelter ST, et al. Standardized International Manual of the Fugl-Meyer Assessment of Motor Function After Stroke. Neurorehabil Neural Repair. 2026. PMID: 41773341. doi:10.1177/15459683251412300
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。