文献速递神经康复

西班牙语境下卒中驾驶人筛查评估的验证

Validation of the Stroke Drivers' Screening Assessment in people with stroke in the Spanish context.
PubMed 文献 · Clin Rehabil · 2026-01-13

结果显示SDSA-西班牙版与注意及记忆测验显著相关,联合其他测验的回归模型预测路考曲线下面积为0.81。结论认为SDSA-西班牙版可作为评估卒中患者驾驶适宜性的非道路工具,尤其适合与其他测验联合使用。

要点

  • SDSA-西班牙版与视野有用子测验2、3及连线测验B部分时间显著相关。
  • 单独使用SDSA-西班牙版区分合格与不合格驾驶人的能力无显著差异。
  • 联合点划消时间、点划消错误、路标识别及视野有用子测验2的模型曲线下面积为0.81。

核心结论

  • SDSA-西班牙版是一种可用于评估卒中患者驾驶适宜性的非道路工具,尤其适合与其他测验联合使用。

研究设计与样本

  • 由两名作业治疗师、一名专攻驾驶的心理学家和一名驾驶教练组成专家组完成SDSA的西班牙语境适配。

主要发现

  • SDSA-西班牙版与视野有用子测验2和3、连线测验B部分时间呈显著相关。
  • 单独使用SDSA-西班牙版时,合格与不合格参与者之间的区分能力无显著差异。
  • 逻辑回归模型纳入点划消时间、点划消错误、路标识别及视野有用子测验2,曲线下面积为0.81,准确率0.73,特异度0.75,敏感度0.714。

关键数值与推荐

  • 逻辑回归模型曲线下面积0.81、准确率0.73、特异度0.75、敏感度0.714。

临床怎么用

  • 可将SDSA-西班牙版作为卒中患者驾驶适宜性的非道路筛查工具,并建议与其他测验联合使用以提高评估效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

ObjectiveTo culturally adapt the Stroke Drivers' Screening Assessment (SDSA) and evaluate its construct and predictive validity in a Spanish stroke population.DesignCultural adaptation and validation study.SettingHospitals and neurorehabilitation clinics in Spain.ParticipantsForty-five stroke patients completed the SDSA-Spain, a neuropsychological battery, and a road test.Adaptation processA panel of experts (two occupational therapists, a psychologist specializing in driving, and a driving instructor) adapted the SDSA to the Spanish context.Main measuresThe correlations of the SDSA-Spain with attention and memory tests, its ability to discriminate between fit and unfit drivers according to the instructor's judgment, and its predictive validity for the road test were analyzed.ResultsThe SDSA-Spain correlated significantly with the Useful Field of View subtests 2 and 3, and with the Trail Making Test-part B time. No significant differences were observed in discriminative ability alone between pass and fail participants. A logistic regression was performed selecting Dot Cancellation-time, Dot Cancellation-errors, Road Sign Recognition from the Spanish SDSA, and Useful Field of View-subtest 2. The model achieved an area under the curve of 0.81, accuracy of 0.73, specificity of 0.75, and sensitivity of 0.714.ConclusionsThe SDSA-Spain is an off-road tool that can be useful for assessing fitness to drive in stroke patients, especially when combined with other tests.

来源:Clin Rehabil,查看原文。版权归原作者所有。

引用

  1. Clavijo-Ruiz J, Szot AC, Laffarga L, et al. Validation of the Stroke Drivers' Screening Assessment in people with stroke in the Spanish context. Clin Rehabil. 2026. PMID: 41529065. doi:10.1177/02692155251414017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。