文献速递脊髓损伤康复神经康复

可穿戴传感器用于脊髓损伤试验日常活动监测的可行性与敏感性

Feasibility and Sensitivity of Wearable Sensors for Daily Activity Monitoring in Spinal Cord Injury Trials.
PubMed 文献 · Neurorehabil Neural Repair · 2025-07-10

该研究基于Nogo-A抑制脊髓损伤试验(NCT03935321)中69例急性创伤性颈段脊髓损伤患者,使用可穿戴惯性传感器在住院康复期间连续监测日常活动,以平均每日能量消耗(EE)作为身体活动指标,并与上肢运动评分(UEMS)和脊髓独立性评定(SCIM)的恢复进行比较。结果显示,verum组每周平均每日EE增加显著高于安慰剂组(ΔEE=11.6 kcal/day/week,95%CI [1.5, 21.8],P=.025),而UEMS和SCIM变化组间无显著差异。结论认为连续传感器活动监测可提供客观且敏感的身体能力变化信息,有望补充临床评估。

要点

  • 可穿戴传感器可在急性颈段脊髓损伤住院康复期间连续监测日常活动。
  • 传感器衍生的平均每日能量消耗(EE)显示verum组每周增加显著高于安慰剂组。
  • 传统临床评估UEMS和SCIM在组间未显示显著变化差异。

核心结论

  • 连续传感器活动监测能客观、敏感地反映脊髓损伤患者身体能力变化,可有效补充周期性临床评估。

研究设计与样本

  • 研究纳入69例急性创伤性颈段脊髓损伤患者,来自Nogo-A Inhibition in Spinal Cord Injury试验(NCT03935321),该试验为2b期、多中心、随机、安慰剂对照试验。
  • 参与者在住院康复期间每周佩戴最多5个惯性传感器,连续最多3天,每周重复。

主要发现

  • verum组(n=41;59.4%)与安慰剂组(n=28;40.6%)初始活动水平相似。
  • verum组平均每日EE每周增加显著高于安慰剂组(ΔEE=11.6 kcal/day/week,95%CI [1.5, 21.8],P=.025)。
  • UEMS变化组间无显著差异(ΔUEMS=0.1/周,95%CI [-0.2, 0.3],P=.603)。
  • SCIM变化组间无显著差异(ΔSCIM=0.2/周,95%CI [-0.7, 1.1],P=.644)。

关键数值与推荐

  • 以平均每日能量消耗(EE)估计值作为身体活动指标。
  • 与上肢运动评分(UEMS)和脊髓独立性评定(SCIM)的恢复进行比较。

临床怎么用

  • 在脊髓损伤临床试验和康复监测中,可考虑使用可穿戴惯性传感器连续采集日常活动数据。
  • 传感器衍生的EE等指标可作为传统临床量表(UEMS、SCIM)的补充,用于评估身体活动变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BackgroundThe aim of clinical trials for spinal cord injury (SCI) is to improve everyday-life activity outcomes, which requires reliable methods for monitoring patient activity. This study evaluates sensor-derived activity metrics in comparison to established clinical assessment methods.MethodsWearable inertial sensors collected data from 69 individuals with acute, traumatic cervical SCI participating in the Nogo-A Inhibition in Spinal Cord Injury trial (NCT03935321), a phase 2b, multicenter, randomized, placebo-controlled trial. During inpatient rehabilitation, participants wore up to 5 inertial sensors for up to 3 consecutive days each week. An estimation of average daily energy expenditure (EE) was used as an indicator of physical activity and compared to the recovery of Upper Extremity Motor Scores (UEMS) and Spinal Cord Independence Measures (SCIM).ResultsParticipants in the verum (n = 41; 59.4%) and placebo (n = 28; 40.6%) groups showed similar initial activity levels, however, the verum group exhibited a significantly greater weekly increase in average daily EE (ΔEE = 11.6 kcal/day/week, 95% CI [1.5, 21.8], P = .025). In contrast, no significant group differences were observed in changes in UEMS (ΔUEMS = 0.1/week, 95% CI [-0.2, 0.3], P = .603) or SCIM (ΔSCIM = 0.2, per week 95% CI [-0.7, 1.1], P = .644).ConclusionContinuous sensor-based activity monitoring offers objective and sensitive insights into changes in physical capabilities, effectively complementing periodic clinical assessments. Thus, sensor-derived outcome measures offer potential for improving the evaluation of clinical studies in individuals with SCI.Clinical Trail Registration:https://clinicaltrials.gov; NCT03935321.

来源:Neurorehabil Neural Repair,查看原文。版权归原作者所有。

引用

  1. Giagiozis M, Lerch I, Linke AD, et al. Feasibility and Sensitivity of Wearable Sensors for Daily Activity Monitoring in Spinal Cord Injury Trials. Neurorehabil Neural Repair. 2025. PMID: 40637209. doi:10.1177/15459683251352556

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。