慢性腰痛疼痛自我效能评估:五种量表头对头比较研究
该研究在245例非特异性慢性腰痛患者中头对头比较PSEQ-10、PSEQ-4、PSEQ-2、CPSS长版及CPSS-SF的测量性能。结果显示仅PSEQ-10满足COSMIN全部良好测量性能标准,为评估慢性腰痛疼痛自我效能的唯一优选量表。
要点
- PSEQ-10是唯一满足COSMIN全部良好测量性能标准的量表。
- CPSS-SF未满足建构效度假设检验标准,PSEQ-2无法计算结构效度。
- 除PSEQ-10外,其余量表均未显示合适的测量误差。
核心结论
- PSEQ-10是唯一满足COSMIN全部良好测量性能标准的疼痛自我效能量表,适用于慢性腰痛患者。
研究设计与样本
- 横断面与纵向测量性能研究,纳入245例18-60岁非特异性慢性腰痛患者,63%为女性,在门诊康复环境中完成。
主要发现
- 除CPSS-SF外,各量表建构效度假设确认率均>75%;PSEQ-2未满足结构效度标准。
- 除PSEQ-10外,所有量表均未显示合适的测量误差。
关键数值与推荐
- 建构效度:假设确认率>75%为达标,CPSS-SF未达标。
- PSEQ-10满足COSMIN全部良好测量性能标准。
临床怎么用
- 临床评估慢性腰痛患者疼痛自我效能时,优先选用PSEQ-10。
- PSEQ-4、PSEQ-2、CPSS长版及CPSS-SF在测量误差或结构效度方面存在不足,不宜替代PSEQ-10。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare the quality of the measurement properties of Pain Self-Efficacy Questionnaire (PSEQ)-10, PSEQ-4, PSEQ-2, Chronic Pain Self-Efficacy Scale (CPSS) long-form, and CPSS short-form (CPSS-SF) in patients with chronic low back pain (CLBP). DESIGN: Cross-sectional and longitudinal studies (measurement properties). SETTING: Outpatient rehabilitation. PARTICIPANTS: Participants (N=245) with nonspecific CLBP (18-60y, 63% women) were enrolled in this study. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Pain self-efficacy questionnaires were administered on 3 occasions: baseline assessment, 1 week after the first assessment (reliability), and after an 8-week exercise program (responsiveness). The intraclass correlation coefficient (ICC) and Cronbach α were used to assess reliability and internal consistency, respectively. Pearson correlation and confirmatory factor analyses were used to assess construct validity. The area under the curve and hypothesis testing were used to assess responsiveness. RESULTS: No difference was observed for all the questionnaires regarding internal consistency (Cronbach α>.7), criterion validity (r>.88), and reliability (ICC>.7). The scales confirmed >75% of the hypotheses for the construct validity, except for CPSS-SF. PSEQ-2 did not meet the criterion for structural validity. PSEQ-10 met all the criteria for good measurement properties according to Consensus-Based Standards for the Selection of Health Measurement Instruments. CONCLUSIONS: It was not possible to calculate structural validity for PSEQ-2, CPSS-SF did not meet the criterion for suitable hypothesis testing for construct validity, and all the questionnaires did not show suitable measurement error, except for the PSEQ-10. Hence, the PSEQ-10 was the unique scale that met all the criteria for good measurement properties for assessing pain self-efficacy in CLBP.
引用
- Turci AM, Spavieri JHP, Lima TC, et al. Which Scale to Assess Pain Self-efficacy Shows Better Measurement Properties in Chronic Low Back Pain? A Head-To-Head Comparison Study. Arch Phys Med Rehabil. 2024. PMID: 38763345. doi:10.1016/j.apmr.2024.05.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。