卒中康复期运动与可穿戴设备睡眠、疲劳及生物标志物的关联
结果发现疲劳严重程度与睡眠质量及夜间觉醒体验显著相关,非瘫侧握力与BDNF基因表达正相关,瘫侧握力与CRP基因表达负相关。提示卒中康复应关注睡眠、疲劳和生物标志物以优化恢复。
要点
- 疲劳严重程度与睡眠质量及夜间觉醒体验显著相关。
- 非瘫侧握力与唾液BDNF基因表达呈正相关。
- 瘫侧握力与唾液CRP基因表达呈负相关。
核心结论
- 卒中康复应重视睡眠质量、疲劳和生物标志物,干预可能需个体化。
- 未来需纵向研究探索这些关系随时间的变化。
- 整合可穿戴睡眠监测与生物标志物分析可增强卒中后结局的监测和预测。
研究设计与样本
- 使用可穿戴Philips Actiwatch客观测量一夜睡眠。
- 采集唾液进行应激、炎症和神经可塑性生物标志物分析。
- 采用相关性分析评估变量间关系。
主要发现
- 患者报告卒中后睡眠质量差、频繁觉醒和入睡困难。
- 疲劳严重程度与睡眠质量呈显著负相关(r=-0.539,p=0.021)。
- 疲劳严重程度与夜间觉醒体验呈显著负相关(r=-0.656,p=0.003)。
- 非瘫侧握力与唾液BDNF基因表达呈显著正相关(r=0.606,p=0.028)。
- 瘫侧握力与唾液CRP基因表达呈显著负相关(r=-0.556,p=0.048)。
临床怎么用
- 卒中康复中应评估睡眠质量和疲劳,并考虑个体化干预。
- 可穿戴设备可用于客观监测卒中后睡眠。
- 唾液生物标志物分析可能辅助监测卒中后恢复。
局限性
- 横断面设计无法确定因果关系。
- 仅测量一夜睡眠,可能不能代表长期睡眠模式。
- 未来需纵向研究验证这些关系。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Sleep disturbance and fatigue are common in individuals undergoing inpatient rehabilitation following stroke. Understanding the relationships between sleep, fatigue, motor performance, and key biomarkers of inflammation and neuroplasticity could provide valuable insight into stroke recovery, possibly leading to personalized rehabilitation strategies. This study aimed to investigate the influence of sleep quality on motor function following stroke utilizing wearable technology to obtain objective sleep measurements. Additionally, we aimed to determine if there were relationships between sleep, fatigue, and motor function. Lastly, the study aimed to determine if salivary biomarkers of stress, inflammation, and neuroplasticity were associated with motor function or fatigue post-stroke. METHODS: Eighteen individuals who experienced a stroke and were undergoing inpatient rehabilitation participated in a cross-sectional observational study. Following consent, participants completed questionnaires to assess sleep patterns, fatigue, and quality of life. Objective sleep was measured throughout one night using the wearable Philips Actiwatch. Upper limb motor performance was assessed on the following day and saliva was collected for biomarker analysis. Correlation analyses were performed to assess the relationships between variables. RESULTS: Participants reported poor sleep quality, frequent awakenings, and difficulties falling asleep following stroke. We identified a significant negative relationship between fatigue severity and both sleep quality (r=-0.539, p = 0.021) and participants experience of awakening from sleep (r=-0.656, p = 0.003). A significant positive relationship was found between grip strength on the non-hemiplegic limb and salivary gene expression of Brain-derived Neurotrophic Factor (r = 0.606, p = 0.028), as well as a significant negative relationship between grip strength on the hemiplegic side and salivary gene expression of C-reactive Protein (r=-0.556, p = 0.048). CONCLUSION: The findings of this study emphasize the importance of considering sleep quality, fatigue, and biomarkers in stroke rehabilitation to optimize recovery and that interventions may need to be tailored to the individual. Future longitudinal studies are required to explore these relationships over time. Integrating wearable technology for sleep and biomarker analysis can enhance monitoring and prediction of outcomes following stroke, ultimately improving rehabilitation strategies and patient outcomes.
引用
- Smith MJ, Pellegrini M, Major B, et al. Improving physical movement during stroke rehabilitation: investigating associations between sleep measured by wearable actigraphy technology, fatigue, and key biomarkers. J Neuroeng Rehabil. 2024. PMID: 38802847. doi:10.1186/s12984-024-01380-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。