分级运动想象联合重复经颅磁刺激对卒中患者上肢运动功能的影响:一项随机对照试验
该前瞻性随机对照试验纳入56例卒中患者,随机分为分级运动想象(GMI)组、重复经颅磁刺激(rTMS)组和联合组,所有患者同时接受常规康复。治疗4周后,三组上肢Fugl-Meyer评分均较基线提高,联合组疗效优于GMI组和rTMS组,且GMI在提高患者主动训练兴趣方面优于rTMS。
要点
- GMI和rTMS单独或联合治疗均能改善卒中患者上肢运动功能。
- 联合治疗在改善上肢Fugl-Meyer评分上优于单一治疗。
- GMI在提高患者主动训练兴趣方面优于rTMS。
核心结论
- GMI和rTMS均能有效改善卒中患者上肢功能,但两者联合效果更佳。
- GMI在提高卒中患者主动训练兴趣方面优于rTMS。
研究设计与样本
- 前瞻性随机对照试验,在康复医院进行,共纳入56例卒中患者。
- 患者随机分为GMI组(n=19)、rTMS组(n=18)和联合组(n=19)。
主要发现
- 治疗4周后,三组上肢Fugl-Meyer评分均较基线提高,组间差异有统计学意义(P=.009)。
- 联合组疗效显著优于GMI组(P=.015)和rTMS组(P=.043)。
- 在运动活动日志-使用量(MAL-AOU)评分上,联合组优于rTMS组(P=.035)。
关键数值与推荐
- 干预措施:1 Hz rTMS 20分钟;GMI 30分钟;所有患者每日接受120分钟物理治疗和作业治疗。
- 治疗频率:每日1次,每周5天,持续4周。
- 主要终点:4周时上肢Fugl-Meyer评分较基线的改善。
临床怎么用
- 对于卒中上肢功能障碍患者,可考虑GMI与rTMS联合治疗以优化运动功能恢复。
- 在制定康复方案时,GMI可能有助于提升患者主动训练参与度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To investigate the efficacy of graded motor imagery therapy (GMI) and repetitive transcranial magnetic stimulation (rTMS) on upper extremity function alone and in combination in patients with stroke. DESIGN: This was a prospective randomized controlled trial. SETTING: A rehabilitation hospital. PARTICIPANTS: Participants (N=56) were randomized into GMI (n=19), rTMS (n=18), or combined groups (n=19). INTERVENTIONS: There were 2 interventions: (1) 20 minutes of 1 Hz rTMS. (2) 30 minutes of GMI. In addition to this, all participants receive conventional rehabilitation including 120 minutes of physical therapy and occupational therapy daily. All treatments were administered once a day, 5 days a week, for 4 weeks. The Fugl-Meyer assessment of upper extremity (FMA-UE), Action Research Arm Test (ARAT), modified Barthel Index (MBI), motor activity log (MAL), and motor evoked potential (MEP) were assessed in a blinded manner at baseline and 4 weeks after treatment, respectively. MAIN OUTCOME MEASURES: The primary endpoint was the improvement from baseline in FMA-UE for stroke patients at 4 weeks. RESULTS: After 4 weeks of treatment, the FMA-UE scores in the GMI, rTMS, and combined groups were higher than those at baseline assessment, with statistically significant differences among the 3 groups (P=.009). The efficacy of the combined group was significantly better than that of the GMI and rTMS groups (P=.015, P=.043, respectively). In the motor activity log-amount of use (MAL-AOU) score, the efficacy of the combined group was better than that of the rTMS group (P=.035). CONCLUSIONS: Both GMI and rTMS were effective in improving upper extremity function in patients with stroke, but the combination of the 2 techniques was more effective. However, GMI was better than rTMS in improving the interest of stroke patients in active training.
引用
- Jia F, Zhao Y, Wang Z, et al. Effect of Graded Motor Imagery Combined With Repetitive Transcranial Magnetic Stimulation on Upper Extremity Motor Function in Stroke Patients: A Randomized Controlled Trial. Arch Phys Med Rehabil. 2023. PMID: 38110138. doi:10.1016/j.apmr.2023.12.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。