文献速递神经康复

使用环形可穿戴设备定量测量脑卒中偏瘫患者的手指使用情况

Quantitative measurement of finger usage in stroke hemiplegia using ring-shaped wearable devices.
PubMed 文献 · J Neuroeng Rehabil · 2023-06-06

结果显示患侧手指使用量与STEF等相关,手指使用比值与FMA-UE、ARAT及STEF相关,而上肢使用量与多项临床评估相关;MAL与任何测量均无相关性。

要点

  • 环形可穿戴设备可同时定量记录偏瘫患者手指与上肢的使用量。
  • 患侧手指使用比值与STEF、FMA-UE、ARAT存在中至强相关。
  • MAL主观评估与可穿戴设备客观测量之间无相关性。

核心结论

  • 环形可穿戴设备提供的客观测量信息不受患者和治疗师主观性影响。

主要发现

  • 患侧手指使用量与STEF及STEF比值呈中度相关。
  • 手指使用比值与FMA-UE、ARAT呈中度相关,与STEF及STEF比值呈强相关。
  • 患侧上肢使用量与FMA-UE、STEF及STEF比值呈中度相关,与ARAT呈强相关。
  • 上肢使用比值与ARAT、STEF呈中度相关,与STEF比值呈强相关。
  • MAL与任何测量之间均无相关性。

临床怎么用

  • 可利用环形可穿戴设备客观监测偏瘫患者日常手指和上肢使用情况,补充临床量表评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In post-stroke rehabilitation, positive use of affected limbs in daily life is important to improve affected upper-limb function. Several studies have quantitatively evaluated the amount of upper-limb activity, but few have measured finger usage. In this study, we used a ring-shaped wearable device to measure upper-limb and finger usage simultaneously in hospitalized patients with hemiplegic stroke and investigated the association between finger usage and general clinical evaluation. METHODS: Twenty patients with hemiplegic stroke in an inpatient hospital participated in this study. All patients wore a ring-shaped wearable device on both hands for 9 h on the day of the intervention, and their finger and upper-limb usage were recorded. For the rehabilitation outcome assessments, the Fugl-Meyer Assessment of the Upper Extremity (FMA-UE), Simple Test for Evaluating Hand Function (STEF), Action Research Arm Test (ARAT), Motor Activity Log-14 (MAL), and Functional Independence Measure Motor (FIM-m) were performed and evaluated on the same day as the intervention. RESULTS: Finger usage of the affected hand was moderately correlated with STEF ([Formula: see text], [Formula: see text]) and STEF ratio ([Formula: see text], [Formula: see text]). The finger-usage ratio was moderately correlated with FMA-UE ([Formula: see text], [Formula: see text]) and ARAT ([Formula: see text], [Formula: see text]), and strongly correlated with STEF ([Formula: see text], [Formula: see text]) and STEF ratio ([Formula: see text], [Formula: see text]). The upper-limb usage of the affected side was moderately correlated with FMA-UE ([Formula: see text], [Formula: see text]), STEF ([Formula: see text], [Formula: see text]) and STEF ratio ([Formula: see text], [Formula: see text]), and strongly correlated with ARAT ([Formula: see text], [Formula: see text]). The upper-limb usage ratio was moderately correlated with ARAT ([Formula: see text], [Formula: see text]) and STEF ([Formula: see text], [Formula: see text]), and strongly correlated with the STEF ratio ([Formula: see text], [Formula: see text]). By contrast, there was no correlation between MAL and any of the measurements. CONCLUSIONS: This measurement technique provided useful information that was not biased by the subjectivity of the patients and therapists.

来源:J Neuroeng Rehabil,查看原文。版权归原作者所有。

引用

  1. Yamamoto N, Matsumoto T, Sudo T, et al. Quantitative measurement of finger usage in stroke hemiplegia using ring-shaped wearable devices. J Neuroeng Rehabil. 2023. PMID: 37280649. doi:10.1186/s12984-023-01199-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。