结果显示内容效度满意,ICC为0.81,最小可检测变化1.94分,最小重要变化1.58分,构建效度中等、反应度高,但出院3个月时25%患者存在天花板效应。结论支持在亚急性卒中住院康复中采用共享决策方式使用PSFS记录和监测患者自选康复目标。

要点

  • PSFS在亚急性卒中康复中信度满意(ICC=0.81),最小可检测变化1.94分。
  • PSFS最小重要变化为1.58分,反应度高(AUC=0.74),构建效度中等。
  • 出院3个月时25%患者出现天花板效应,长期随访需注意。

核心结论

  • PSFS在亚急性期脑卒中住院康复患者中显示满意的测量特性,支持以共享决策方式用于记录和监测患者自选康复目标。

主要发现

  • 信度ICC为0.81(95%CI=0.69-0.89),测量标准误为0.70分。
  • 构建效度7个假设中5个被证实,反应度6个假设中5个被证实。
  • 出院3个月时25%的参与者存在天花板效应。

关键数值与推荐

  • 最小可检测变化为1.94分,最小重要变化估计为1.58分。
  • 反应度 criterion 法的曲线下面积为0.74。

临床怎么用

  • 可在亚急性卒中住院康复中采用共享决策方式使用PSFS记录和监测患者自选康复目标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study investigated the validity, reliability, responsiveness, and interpretability of the Patient-Specific Functional Scale (PSFS) in subacute stroke rehabilitation to determine its suitability to measure patient-identified rehabilitation goals. METHODS: A prospective observational study was designed according to the checklist from Consensus-Based Standards for Selecting Health Measurement Instruments. Seventy-one patients diagnosed with stroke were recruited in the subacute phase from a rehabilitation unit in Norway. The International Classification of Functioning, Disability and Health was used to assess the content validity. Assessment of construct validity was based on hypotheses for correlation of the PSFS and comparator measurements. We assessed reliability by calculating the Intraclass Correlation Coefficient (ICC) (3.1) and the standard error of measurement. The assessment of responsiveness was based on hypotheses for the correlation of change scores between the PSFS and the comparator measurements. A receiver operating characteristic analysis was conducted to assess responsiveness. The smallest detectable change and minimal important change were calculated. RESULTS: Eighty percent of the PSFS items were classified as activities and participation in the International Classification of Functioning, Disability and Health, indicating satisfactory content validity. The reliability was satisfactory with an ICC of 0.81 (95% CI = 0.69-0.89). The standard error of measurement was 0.70 point, and the smallest detectable change was 1.94 points. Five of 7 hypotheses were confirmed for construct validity, and 5 of 6 were confirmed for responsiveness, indicating moderate construct validity and high responsiveness. Assessing responsiveness with a criterion approach resulted in an area under the curve of 0.74. A ceiling effect was identified for 25% of the participants 3 months after discharge. The minimal important change was estimated to be 1.58 points. CONCLUSION: This study demonstrates satisfactory measurement properties for the PSFS in individuals undergoing inpatient stroke rehabilitation. IMPACT: This study supports the use of the PSFS to document and monitor patient-identified rehabilitation goals in patients receiving subacute stroke rehabilitation when applied using a shared decision approach.

来源:Phys Ther,查看原文。版权归原作者所有。

引用

  1. Evensen J, Soberg HL, Sveen U, et al. Measurement Properties of the Patient-Specific Functional Scale in Rehabilitation for Patients With Stroke: A Prospective Observational Study. Phys Ther. 2023. PMID: 37140476. doi:10.1093/ptj/pzad014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。