可穿戴动力机器人辅助步态训练在卒中康复中的随机平行组试验
共35例完成分析,15天10次训练后两组主要结局(10米步行时间和6分钟步行距离改善率)无显著差异,但A组步态持续时间(p=0.006)和步频(p=0.012)的组间交互效应更优。
要点
- 可穿戴机器人辅助步态训练未显著优于常规训练的主要结局。
- A组步态持续时间和步频改善显著优于B组。
- 两组步行速度、步长等指标在14天内均显著改善。
核心结论
- 新型可穿戴动力机器人可能有助于改善卒中康复患者的步态速度。
- 在主要结局上,机器人辅助步态训练与常规治疗师辅助步态训练无显著差异。
研究设计与样本
- 临床试验期15天,每周5次共10次步态训练,每次30±5分钟。
- 35例患者数据纳入分析,主要结局为10米步行时间和6分钟步行距离的改善率。
主要发现
- 训练结束时两组主要结局无显著差异。
- 两组内步行速度、步长、步态持续时间和步频在第0天至第14天均显著改善。
- 测量日与分组交互效应显示,A组步态持续时间(p=0.006)和步频(p=0.012)改善显著优于B组。
关键数值与推荐
- 主要结局为10米步行时间和6分钟步行距离的改善率,改善率=(第14天值-第0天值)/第0天值。
- 次要评估包括计时起立行走测试、Berg平衡量表(BBS)及RehaGait®测量的步态参数。
- BBS仅在第0天和第14天测量,其他项目在第0、7、14天测量。
临床怎么用
- 可穿戴动力机器人可作为卒中步态训练的辅助手段,可能改善步频和步态持续时间。
- 常规治疗师辅助步态训练仍是有效方案,机器人训练未显示主要结局优势。
局限性
- 原文未报告样本量计算、盲法及脱落原因等细节。
- 试验周期较短(15天),长期效果未评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We have developed a wearable rehabilitation robot, "curara®," and examined its immediate effect in patients with spinocerebellar degeneration and stroke, but its rehabilitative effect has not been clarified. The purpose of this study was to examine the effect of this device on gait training in stroke patients. METHODS: Forty stroke patients were enrolled in this study. The participants were divided randomly into two groups (groups A and B). The participants assigned to group A received RAGT with curara® type 4, whereas those in group B received conventional therapist-assisted gait training. The clinical trial period was 15 days. The participants performed 10 sessions of gait training (5 times per week) each lasting 30 ± 5 min per day. The 10-m walking time (10mWT), and 6-minute walking distance (6MWD) were evaluated as the main outcomes. Timed up and go and Berg Balance Scale (BBS) were also examined. Gait parameters (stride duration and length, standard deviation of stride duration and length, cadence, ratio of the stance/swing phases, minimum/maximum knee joint angle, and minimum/maximum hip joint angle) were measured using a RehaGait®. The items other than BBS were measured on days 0, 7, and 14, whereas BBS was measured on days 0 and 14. The improvement rate was calculated as the difference of values between days 14 and 0 divided by the value on day 0. The improvement rates of the 10mWT and 6MWD were set as the main outcomes. RESULTS: The data of 35 participants were analyzed. There was no significant difference in the main outcomes between both groups at the end of gait training. As for intragroup changes, gait speed, stride length, stride duration, and cadence were improved significantly between days 0 and 14 in each group. When examining the interaction effect between the day of measurement and group, stride duration (p = 0.006) and cadence (p = 0.012) were more significantly improved in group A than in group B. CONCLUSIONS: This novel wearable powered robot may have the potential to improve gait speed of individuals in stroke rehabilitation. TRIAL REGISTRATION: Japan Registry of Clinical Trials (jRCTs032180163). Registered on February 22, 2019; https://jrct.niph.go.jp/en-latest-detail/jRCTs032180163 . UMIN CLINICAL TRIALS REGISTRY (UMIN000034237): Registered on September 22, 2018; https://center6.umin.ac.jp/cgi-open-bin/icdr/ctr_view.cgi?recptno=R000038939 .
引用
- Miyagawa D, Matsushima A, Maruyama Y, et al. Gait training with a wearable powered robot during stroke rehabilitation: a randomized parallel-group trial. J Neuroeng Rehabil. 2023. PMID: 37118743. doi:10.1186/s12984-023-01168-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。