文献速递神经康复

脑卒中患者计时起立行走障碍测试的信度、同时效度与最小可检测变化

Reliability, Concurrent Validity, and Minimal Detectable Change of Timed Up and Go Obstacle Test in People With Stroke.
PubMed 文献 · Arch Phys Med Rehabil · 2023-03-21

OBJECTIVE: The aims of this study were to investigate the psychometric property of the timed Up and Go Obstacle (TUGO) test in people with stroke. DESIGN: Cross-sectional design. SETTING: University based neurorehabilitation laboratory.…

要点

  • TUGO在0、5、17 cm障碍高度下评定者间信度ICC为0.999–1.000,重测信度ICC为0.917–0.975。
  • TUGO完成时间与NCWT和TUG完成时间显著相关(r=0.817–0.912)。
  • 0、5、17 cm障碍高度的MDC分别为2.54、3.60、3.07 s,最佳截断值分别为14.69、14.76、16.10 s。

核心结论

  • TUGO测试是可靠、有效且易于实施的临床测量工具,可区分脑卒中患者与健康老年人。

主要发现

  • 所有障碍高度下TUGO完成时间的评定者间信度ICC为0.999–1.000,重测信度ICC为0.917–0.975。
  • 所有障碍高度下TUGO完成时间与NCWT和TUG完成时间显著相关(r=0.817–0.912)。
  • 仅0和5 cm障碍高度TUGO完成时间与BBS评分显著相关(r=-0.518至-0.534),17 cm障碍高度TUGO完成时间与FMA评分显著相关。
  • 0、5、17 cm障碍高度的MDC分别为2.54、3.60、3.07 s,最佳截断值分别为14.69、14.76、16.10 s。

关键数值与推荐

  • 0 cm障碍高度TUGO完成时间MDC为2.54 s,最佳截断值为14.69 s。
  • 5 cm障碍高度TUGO完成时间MDC为3.60 s,最佳截断值为14.76 s。
  • 17 cm障碍高度TUGO完成时间MDC为3.07 s,最佳截断值为16.10 s。

临床怎么用

  • 可将TUGO用于脑卒中患者步行与平衡能力的临床评估,并参考各障碍高度的MDC和截断值解读变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aims of this study were to investigate the psychometric property of the timed Up and Go Obstacle (TUGO) test in people with stroke. DESIGN: Cross-sectional design. SETTING: University based neurorehabilitation laboratory. PARTICIPANTS: Twenty-eight people with stroke and 30 healthy older adults. INTERVENTION: Not Applicable. OUTCOME MEASURES: The TUGO (obstacle heights: 0, 5, 17 cm) test completion times, Fugl-Meyer Assessment (FMA) score, ankle dorsiflexor and plantarflexor muscle strength, Berg Balance Scale (BBS) score, Narrow Corridor Walking Test (NCWT) completion time, timed Up and Go (TUG) test completion time, and Community Integrated Measure. RESULTS: Excellent inter-rater (intraclass correlation coefficient [ICC]=0.999-1.000) and test-retest reliabilities (ICC=0.917-0.975) were found for TUGO test completion times for all obstacle heights. The TUGO test completion times for all obstacle heights were significantly correlated with NCWT and TUG test completion times (r=0.817-0.912). Only TUGO test completion times for 0 and 5 cm obstacle heights showed significant correlations with BBS scores (r=-0.518 to -0.534), while the TUGO test completion time for the 17 cm obstacle height correlated significantly with FMA scores. The minimal detectable change and optimal cut-off values for TUGO test completion times for the 0, 5, and 17 cm obstacle heights were 2.54, 3.60, and 3.07 s, and 14.69, 14.76, and 16.10 s, respectively. CONCLUSION: The TUGO test is a reliable, valid, and easy-to-administer clinical measure to discriminate between people with stroke and healthy older adults.

来源:Arch Phys Med Rehabil,查看原文。版权归原作者所有。

引用

  1. Ng SSM, Tse MMY, Chen P, et al. Reliability, Concurrent Validity, and Minimal Detectable Change of Timed Up and Go Obstacle Test in People With Stroke. Arch Phys Med Rehabil. 2023. PMID: 36948376. doi:10.1016/j.apmr.2023.03.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。